Developing the high energy performance standards for oil-injected air-cooled screw air compressor for Thailand

被引:3
|
作者
Wiratkasem, Kengkamon [1 ]
Pattana, Somchai [1 ]
Tippayawong, Korrakot Yaibuathet [1 ]
Tippayawong, Nakorn [1 ]
机构
[1] Chiang Mai Univ, Fac Engn, Dept Mech Engn, Chiang Mai 50200, Thailand
关键词
Energy efficiency; Screw air compressor; Air-cooled oil-injected; HEPS;
D O I
10.1016/j.egyr.2019.11.128
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The objective of this wok was to develop the high energy performance standards (HEPS) for oil-injected air-cooled screw air compressors in Thailand. Based on the data from the Customs Department in 2018, it was found that Thailand imported a great number of air compressors with total value of more than 60 million USD. In this study, the energy performance of the air compressors was evaluated from standardized tests, and the energy performance data was used to analyze the energy efficiency standards using statistical principles of normal curves and standard scores. The criteria used in determining the HEPS was that about 30% of the products must have the specific power higher than the HEPS value. The HEPS value was shown in the form of equations to be able to use with all the power input. If it is promoted to adopt this HEPS, Thailand will have the potential to save energy by about 37,305,000 kWh/year. (C) 2019 Published by Elsevier Ltd.
引用
收藏
页码:617 / 621
页数:5
相关论文
共 50 条
  • [1] Performance analysis of an oil-injected screw compressor and its application
    Muroran Inst of Technology, Hokkaido, Japan
    Int J Refrig, 4 (220-227):
  • [2] PERFORMANCE ANALYSIS OF AN OIL-INJECTED SCREW COMPRESSOR AND ITS APPLICATION
    FUJIWARA, M
    OSADA, Y
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (04): : 220 - 227
  • [3] Interactions between air-cooled refrigeration system and screw compressor design
    Sauls, J
    COMPRESSORS AND THEIR SYSTEMS, 2001, 2001 (07): : 13 - 21
  • [4] HIGH PERFORMANCE AIR-COOLED MODULE.
    Anon
    IBM technical disclosure bulletin, 1985, 28 (07): : 3058 - 3059
  • [5] Performance modelling of air-cooled twin-circuit screw chiller
    Lee, S. H.
    Yik, F. W. H.
    Lai, J. H. K.
    Lee, W. L.
    APPLIED THERMAL ENGINEERING, 2010, 30 (10) : 1179 - 1187
  • [6] High-pulse-energy air-cooled lasers
    Kilmer, Joyce
    Kilmer, Joyce (jkilmer@photonix.com), 1600, Laurin Publishing Co. Inc. (54): : 45 - 49
  • [7] Energy saving and performance analysis of air-cooled photovoltaic panels
    Hussam, Wisam K.
    Khlefat, Ali M.
    Sheard, Gregory J.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (04) : 4825 - 4834
  • [8] Energy performance of air-cooled chillers with sprayed water on condenser
    Lu, Jian
    Ren, Shengfeng
    Yang, Junlan
    Chang, Ru
    Shen, Zheng
    Yang, Hongxing
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 355 - 362
  • [9] Performance evaluation of energy efficient evaporatively air-cooled chiller
    Kabeel, A. E.
    El-Samadony, Y. A. F.
    Khiera, M. H.
    APPLIED THERMAL ENGINEERING, 2017, 122 : 204 - 213
  • [10] Improved energy performance of air-cooled chiller system with mist pre-cooling Mist improvement on air-cooled chillers
    Yu, F. W.