Energy performance of air-cooled chillers with sprayed water on condenser

被引:0
|
作者
Lu, Jian [1 ]
Ren, Shengfeng [1 ]
Yang, Junlan [1 ]
Chang, Ru [1 ]
Shen, Zheng [1 ]
Yang, Hongxing
机构
[1] Tianjin Inst Urban Construct, Dept Energy Tech & Mech Engn, Tianjin, Peoples R China
关键词
sprayed-water condenser; air-cooled condenser; evaporative cooling; coefficient of performance;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to the effective energy performance, water-cooled condensers have been applied to the air-conditioning systems in many areas. However, most of the air-conditioning systems existing in Hone, Kong employed the use of air-cooled condensers. In order to improve the energy efficiency and effectiveness of those existing air-cooled condensers, a new combination of sprinkler-system operated with the existing air-cooled chiller comes forth. It applies the principle of evaporative cooling to the existing conventional air-cooled chillers by spraying fresh water. This paper aims to test and analyze the feasibility and energy performance of the new combination. Calculations show that the new combination achieved up to 50% increase in the coefficient of performance (COP) of air-cooled chillers in this tropical region of Hong Kong, and the annual energy saving is obvious.
引用
收藏
页码:355 / 362
页数:8
相关论文
共 50 条
  • [1] Optimum condenser fan staging for air-cooled chillers
    Yu, FW
    Chan, KT
    APPLIED THERMAL ENGINEERING, 2005, 25 (14-15) : 2204 - 2218
  • [2] Improved energy performance of air-cooled water chillers with innovative condenser coil configurations - Part II: Experimental validation
    Lee, Tzong-Shing
    Wu, Wu-Chieh
    Jiang, Jin-Cheng
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (08): : 2212 - 2222
  • [3] Improved energy performance of air-cooled water chillers with innovative condenser coil configurations - Part I: CFD simulation
    Lee, Tzong-Shing
    Wu, Wu-Chieh
    Wang, Sheng-Kai
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (08): : 2199 - 2211
  • [4] EXPERIMENTAL STUDIES OF ENERGY PERFORMANCE OF AIR-COOLED CHILLERS WITH WATER MIST SYSTEM
    Yang, Jia
    Chan, Kwok-tai
    Wu, Xiang-sheng
    PROCEEDINGS OF THE SECOND INTERNATIONAL POSTGRADUATE CONFERENCE ON INFRASTRUCTURE AND ENVIRONMENT, VOL 1, 2010, : 21 - 30
  • [5] Improved condenser design and condenser-fan operation for air-cooled chillers
    Yu, FW
    Chan, KT
    APPLIED ENERGY, 2006, 83 (06) : 628 - 648
  • [6] Optimizing condenser fan control for air-cooled centrifugal chillers
    Yu, F. W.
    Chan, K. T.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2008, 47 (07) : 942 - 953
  • [7] A STUDY ON AIR-COOLED CHILLERS WITH EVAPORATIVELY COOLED CONDENSER FOR 3 TYPES OF CLIMATE
    Kocak Soylu, Sezgi
    Atmaca, Ibrahim
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2016, 36 (01) : 1 - 8
  • [8] An analysis on the energy efficiency of air-cooled chillers with water mist system
    Yang, Jia
    Chan, K. T.
    Wu, Xiangsheng
    Yu, F. W.
    Yang, Xiaofeng
    ENERGY AND BUILDINGS, 2012, 55 : 273 - 284
  • [9] Part load performance of air-cooled centrifugal chillers with variable speed condenser fan control
    Yu, F. W.
    Chan, K. T.
    BUILDING AND ENVIRONMENT, 2007, 42 (11) : 3816 - 3829
  • [10] Air-cooled condenser
    Phogat, S.S.
    Journal of the Institution of Engineers (India): Mechanical Engineering Division, 1988, 68 pt 6 : 191 - 195