Energy performance of air-cooled chillers with sprayed water on condenser

被引:0
|
作者
Lu, Jian [1 ]
Ren, Shengfeng [1 ]
Yang, Junlan [1 ]
Chang, Ru [1 ]
Shen, Zheng [1 ]
Yang, Hongxing
机构
[1] Tianjin Inst Urban Construct, Dept Energy Tech & Mech Engn, Tianjin, Peoples R China
关键词
sprayed-water condenser; air-cooled condenser; evaporative cooling; coefficient of performance;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Due to the effective energy performance, water-cooled condensers have been applied to the air-conditioning systems in many areas. However, most of the air-conditioning systems existing in Hone, Kong employed the use of air-cooled condensers. In order to improve the energy efficiency and effectiveness of those existing air-cooled condensers, a new combination of sprinkler-system operated with the existing air-cooled chiller comes forth. It applies the principle of evaporative cooling to the existing conventional air-cooled chillers by spraying fresh water. This paper aims to test and analyze the feasibility and energy performance of the new combination. Calculations show that the new combination achieved up to 50% increase in the coefficient of performance (COP) of air-cooled chillers in this tropical region of Hong Kong, and the annual energy saving is obvious.
引用
收藏
页码:355 / 362
页数:8
相关论文
共 50 条
  • [21] Performance improvement of air-cooled refrigeration system by using evaporatively cooled air condenser
    Hajidavalloo, E.
    Eghtedari, H.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (05): : 982 - 988
  • [22] Air-cooled chillers for hot, dry climates
    Howell, RH
    ASHRAE JOURNAL, 2003, 45 (12) : 38 - +
  • [23] Air-Cooled Chillers For Las Vegas Revisited
    Howell, Ronald H.
    Land, Donald W.
    Land, John M.
    ASHRAE JOURNAL, 2014, 56 (12) : 36 - 44
  • [25] Applying condensing-temperature control in air-cooled reciprocating water chillers for energy efficiency
    Chan, KT
    Yu, FW
    APPLIED ENERGY, 2002, 72 (3-4) : 565 - 581
  • [26] Numerical study on performance improvement of air-cooled condenser 1 by water spray cooling
    Xiao, Liehui
    Ge, Zhihua
    Yang, Lijun
    Du, Xiaoze
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 125 : 1028 - 1042
  • [27] Analysis of dynamic performance of air-cooled condenser structure system
    Sun, Ying
    Hong, Yan
    PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 2675 - +
  • [28] Life cycle analysis of enhanced condenser features for air-cooled chillers serving air-conditioned buildings
    Yu, FW
    Chan, KT
    BUILDING AND ENVIRONMENT, 2006, 41 (08) : 981 - 991
  • [29] Application of direct evaporative coolers for improving the energy efficiency of air-cooled chillers
    Yu, FW
    Chan, KT
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (03): : 430 - 433
  • [30] Tactics to optimize the energy efficiency of a chiller system with multiple air-cooled chillers
    Chan, K
    Yu, FW
    ENERGY AND ENVIRONMENT, VOLS 1 AND 2, 2003, : 1419 - 1424