Optical Assessment of Soft Contact Lens Edge-Thickness

被引:9
|
作者
Tankam, Patrice [1 ,2 ]
Won, Jungeun [3 ]
Canavesi, Cristina [4 ]
Cox, Ian [2 ,5 ]
Rolland, Jannick P. [1 ,2 ,3 ,4 ]
机构
[1] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
[2] Univ Rochester, Ctr Visual Sci, Rochester, NY 14627 USA
[3] Univ Rochester, Dept Biomed Engn, Rochester, NY 14627 USA
[4] LighTopTech Corp, West Henrietta, NY USA
[5] IGC Consulting, New York, NY USA
基金
美国国家科学基金会;
关键词
soft contact lens; edge-thickness; optical coherence tomography; microscopy; optical metrology; TFOS INTERNATIONAL WORKSHOP; COHERENCE TOMOGRAPHY; IN-VIVO; HIGH-SPEED; DISCOMFORT; MICROSCOPY; EPITHELIUM; QUALITY; VISION; DESIGN;
D O I
10.1097/OPX.0000000000000892
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the edge shape of soft contact lenses using Gabor-Domain Optical Coherence Microscopy (GD-OCM) with a 2-mu m imaging resolution in three dimensions and to generate edge-thickness profiles at different distances from the edge tip of soft contact lenses. Methods. A high-speed custom-designed GD-OCM system was used to produce 3D images of the edge of an experimental soft contact lens (Bausch + Lomb, Rochester, NY) in four different configurations: in air, submerged into water, submerged into saline with contrast agent, and placed onto the cornea of a porcine eyeball. An algorithm to compute the edge-thickness was developed and applied to cross-sectional images. The proposed algorithm includes the accurate detection of the interfaces between the lens and the environment, and the correction of the refraction error. Results. The sharply defined edge tip of a soft contact lens was visualized in 3D. Results showed precise thickness measurement of the contact lens edge profile. Fifty cross-sectional image frames for each configuration were used to test the robustness of the algorithm in evaluating the edge-thickness at any distance from the edge tip. The precision of the measurements was less than 0.2 mu m. Conclusions. The results confirmed the ability of GD-OCM to provide high-definition images of soft contact lens edges. As a nondestructive, precise, and fast metrology tool for soft contact lens measurement, the integration of GD-OCMin the design and manufacturing of contact lenses will be beneficial for further improvement in edge design and quality control. In the clinical perspective, the in vivo evaluation of the lens fitted onto the cornea will advance our understanding of how the edge interacts with the ocular surface. The latter will provide insights into the impact of long-term use of contact lenses on the visual performance.
引用
收藏
页码:987 / 996
页数:10
相关论文
共 50 条
  • [21] Characterization of Soft Contact Lens Edge Fitting during Daily Wear Using Ultrahigh-Resolution Optical Coherence Tomography
    Cui, Lele
    Chen, Sisi
    Zhou, Weihe
    Sheng, Kaixuan
    Zhang, Lei
    Shen, Meixiao
    Li, Ming
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [22] Non-contact, optical measurement of lens capsule thickness ex vivo
    Ziebarth, N
    Manns, F
    Uhlhorn, S
    Parel, JM
    OPHTHALMIC TECHNOLOGIES XIV, 2004, 5314 : 1 - 9
  • [23] Assessment of corneal thickness and tear meniscus during contact-lens wear
    Del Aguila-Carrasco, Antonio J.
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Esteve-Taboada, Jose J.
    Montes-Mico, Robert
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (03): : 185 - 193
  • [24] A CONTACT LENS FOR ESTIMATING CORNEAL THICKNESS
    FRIEDMAN, B
    EYE EAR NOSE AND THROAT MONTHLY, 1967, 46 (03): : 344 - &
  • [25] The impact of contact lens care solutions on the thickness of the tear film and contact lens
    Nichols, JJ
    Mitchell, GL
    King-Smith, PE
    CORNEA, 2005, 24 (07) : 825 - 832
  • [26] Lens Replacement Habits in Soft Contact Lens Wearers
    Petricek, Igor
    Lovric, Ivana
    Pokupec, Rajko
    Jandrokovic, Sonja
    COLLEGIUM ANTROPOLOGICUM, 2013, 37 : 175 - 178
  • [27] Effects of long-term soft contact lens wear on the corneal thickness and corneal epithelial thickness of myopic subjects
    Lei, Yulin
    Zheng, Xiuyun
    Hou, Jie
    Xu, Baozeng
    Mu, Guoying
    MOLECULAR MEDICINE REPORTS, 2015, 11 (03) : 2020 - 2026
  • [28] Comparison of soft contact lens comfort using three contact lens materials and four contact lens solutions
    Berntsen, David A.
    Hickson-Curran, Sheila B.
    Jones, Lyndon William
    Mathew, Jessica Horne
    Mirza, Aftab A.
    Morgan, Philip B.
    Schulze, Marc M.
    Nichols, Jason J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [29] Quantitative Assessment of Bandage Soft Contact Lens Wear Immediately After LASIK
    Orucov, Faik
    Frucht-Pery, Joseph
    Raiskup, Frederick D.
    Strasman, Eyal
    Landau, David
    Solomon, Abraham
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (10) : 744 - 748
  • [30] The effect of soft contact lens thickness in visual function after intracorneal ring segments surgery
    Carracedo, G.
    Canales, J.
    Gonzalez, P.
    Recchioni, A.
    Carpena-Torres, C.
    Carballo-Alvarez, J.
    CONTACT LENS & ANTERIOR EYE, 2018, 41 (02): : 180 - 186