Non-contact, optical measurement of lens capsule thickness ex vivo

被引:0
|
作者
Ziebarth, N [1 ]
Manns, F [1 ]
Uhlhorn, S [1 ]
Parel, JM [1 ]
机构
[1] Univ Miami, Coll Engn, Biomed Opt & Laser Lab, Dept Biomed Engn, Coral Gables, FL 33124 USA
来源
OPHTHALMIC TECHNOLOGIES XIV | 2004年 / 5314卷
关键词
D O I
10.1117/12.538655
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To design a non-contact optical system to measure lens capsule thickness in cadaver eyes. Methods: The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused onto the tissue using an aspheric lens (NA=0.68) mounted on a motorized translation stage. Light reflected from the sample is collected by the fiber coupler and sent to a silicon photodiode connected to a power meter. Peaks in the power signal are detected when the focal point of the aspheric lens coincides with the capsule boundaries. The capsule thickness is proportional to the distance between successive peaks. Anterior and posterior lens capsule thickness measurements were performed on 13 human,10 monkey, and 34 New Zealand white rabbit lenses. The cadaver eyes were prepared for optical measurements by bonding a PMMA ring on the sclera. The posterior pole was sectioned, excess vitreous was removed, and the eye was placed on a Teflon slide. The cornea and iris were then sectioned. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Results: Central anterior lens capsule thickness was 9.4+/-2.9mum (human), 11.2+/-6.6mum (monkey), and 10.3+/-3.6mum (rabbit) optically and 14.9+/-1.6mum (human), 17.7+/-4.9mum (monkey), and 12.6+/-2.3mum (rabbit) histologically. The values for the central posterior capsule were 9.4+/-2.9mum (human), 6.6+/-2.5mum (monkey), and 7.9+/-2.3mum (rabbit) optically and 4.6+/-1.4mum (human), 4.5+/-1.2mum (monkey), and 5.7+/-1.7mum (rabbit) histologically. Conclusions: This study demonstrates that a non-contact optical system can successfully measure lens capsule thickness in cadaver eyes.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [1] Non-contact optical measurement of lens capsule thickness during simulated accommodation
    Ziebarth, N
    Manns, F
    Acosta, AC
    Parel, JM
    Ophthalmic Technologies XV, 2005, 5688 : 19 - 25
  • [2] Measurement of lens capsule thickness in eyebank eyes using a non-contact optical system: Feasibility
    Ziebarth, NM
    Manns, F
    Uhlhorn, S
    Stoiber, J
    Parel, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U45 - U45
  • [3] Comparison of histology and a non-contact optical system to measure lens capsule thickness.
    Ziebarth, NM
    Mann, F
    Uhlhorn, S
    Lamar, P
    Parel, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U706 - U706
  • [4] New non-contact thickness measurement
    Reusch, M.
    Theobald, N.
    WOCHENBLATT FUR PAPIERFABRIKATION, 2009, 137 (10): : 448 - 449
  • [5] Non-contact coating thickness measurement
    Chandler, PE
    Quigley, MBC
    Fletcher, JF
    THERMAL SPRAY, VOLS 1 AND 2: MEETING THE CHALLENGES OF THE 21ST CENTURY, 1998, : 875 - 879
  • [6] Non-contact Measurement of Plastic Film Thickness
    He Ping
    Liu Chao
    Li Qi
    Cao Shengmei
    2014 33RD CHINESE CONTROL CONFERENCE (CCC), 2014, : 7462 - 7465
  • [7] Optical Non-Contact Micrometer Thickness Measurement System for Silica Thick Films
    Thambiratnam, K.
    Ahmad, H.
    Yasin, M.
    Zulkifli, A. Z.
    Harun, S. W.
    REFLECTION, SCATTERING, AND DIFFRACTION FROM SURFACES III, 2012, 8495
  • [8] In vivo non-contact measurement of human iris elasticity by optical coherence elastography
    Ye, Shuling
    Zhou, Yuheng
    Bao, Chenhong
    Chen, Yulei
    Lu, Fan
    Zhu, Dexi
    JOURNAL OF BIOPHOTONICS, 2021, 14 (09)
  • [9] Non-contact thickness measurement with multilayer radiation structure
    Haroune, Feddal
    Mohamed, Tellache
    Mohamed, El Afendi
    Tao Junwu
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2018, 60 (10) : 2429 - 2437
  • [10] Optical Methods in Non-contact Velocity Measurement
    Smid, Petr
    PROCEEDINGS OF THE 48TH INTERNATIONAL SCIENTIFIC CONFERENCE ON EXPERIMENTALNI ANALYZA NAPETI 2010 EXPERIMENTAL STRESS ANALYSIS, 2010, : 401 - 406