Non-contact, optical measurement of lens capsule thickness ex vivo

被引:0
|
作者
Ziebarth, N [1 ]
Manns, F [1 ]
Uhlhorn, S [1 ]
Parel, JM [1 ]
机构
[1] Univ Miami, Coll Engn, Biomed Opt & Laser Lab, Dept Biomed Engn, Coral Gables, FL 33124 USA
来源
OPHTHALMIC TECHNOLOGIES XIV | 2004年 / 5314卷
关键词
D O I
10.1117/12.538655
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To design a non-contact optical system to measure lens capsule thickness in cadaver eyes. Methods: The optical system uses a 670nm laser beam delivered to a single-mode fiber coupler. The output of the fiber coupler is focused onto the tissue using an aspheric lens (NA=0.68) mounted on a motorized translation stage. Light reflected from the sample is collected by the fiber coupler and sent to a silicon photodiode connected to a power meter. Peaks in the power signal are detected when the focal point of the aspheric lens coincides with the capsule boundaries. The capsule thickness is proportional to the distance between successive peaks. Anterior and posterior lens capsule thickness measurements were performed on 13 human,10 monkey, and 34 New Zealand white rabbit lenses. The cadaver eyes were prepared for optical measurements by bonding a PMMA ring on the sclera. The posterior pole was sectioned, excess vitreous was removed, and the eye was placed on a Teflon slide. The cornea and iris were then sectioned. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Results: Central anterior lens capsule thickness was 9.4+/-2.9mum (human), 11.2+/-6.6mum (monkey), and 10.3+/-3.6mum (rabbit) optically and 14.9+/-1.6mum (human), 17.7+/-4.9mum (monkey), and 12.6+/-2.3mum (rabbit) histologically. The values for the central posterior capsule were 9.4+/-2.9mum (human), 6.6+/-2.5mum (monkey), and 7.9+/-2.3mum (rabbit) optically and 4.6+/-1.4mum (human), 4.5+/-1.2mum (monkey), and 5.7+/-1.7mum (rabbit) histologically. Conclusions: This study demonstrates that a non-contact optical system can successfully measure lens capsule thickness in cadaver eyes.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [41] In vivo non-contact specular microscopy of the lens epithelium of human cataractous lenses
    Tung, WH
    Ayaki, M
    Raghavan, A
    Balaram, M
    Wolfe, JK
    Shinohara, T
    Chylack, LT
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 1624 - 1624
  • [42] Non-contact thickness sensor for containers
    Glass, 2000, 77 (05):
  • [43] Non-contact temperature measurement
    Metallurgia, 1995, 62 (02):
  • [44] Evaluation of the microstructure of cornea by in vivo confocal microscopy in contact lens wearing and non-contact lens wearing keratoconus patients
    Yeniad, Baris
    Yilmaz, Senay
    Bilgin, Lale Kozer
    CONTACT LENS & ANTERIOR EYE, 2010, 33 (04): : 167 - 170
  • [45] NON-CONTACT SPEED MEASUREMENT
    KENYON, M
    VANHOEK, HC
    PORTER, CA
    AUSTRALIAN JOURNAL OF INSTRUMENTATION & CONTROL, 1981, 37 (06): : 114 - 117
  • [46] PROGRESS IN NON-CONTACT MEASUREMENT
    LEWIS, GE
    CME-CHARTERED MECHANICAL ENGINEER, 1981, 28 (08): : 31 - 32
  • [47] Non-contact temperatures measurement
    Materiales de Construccion, 62 (238):
  • [48] NON-CONTACT MEASUREMENT BY RADIOACTIVITY
    BOND, A
    PROCESS ENGINEERING, 1975, (MAR) : 62 - 63
  • [49] Non-contact temperature measurement
    不详
    INDUSTRIAL CERAMICS, 2001, 21 (01): : 56 - 56
  • [50] An optical fiber interferometric system for non-contact measurement of atmospheric optical turbulence
    Mei, HP
    Rao, RZ
    2ND INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, PTS 1 AND 2, 2006, 6150