Optical Assessment of Soft Contact Lens Edge-Thickness

被引:9
|
作者
Tankam, Patrice [1 ,2 ]
Won, Jungeun [3 ]
Canavesi, Cristina [4 ]
Cox, Ian [2 ,5 ]
Rolland, Jannick P. [1 ,2 ,3 ,4 ]
机构
[1] Univ Rochester, Inst Opt, Rochester, NY 14627 USA
[2] Univ Rochester, Ctr Visual Sci, Rochester, NY 14627 USA
[3] Univ Rochester, Dept Biomed Engn, Rochester, NY 14627 USA
[4] LighTopTech Corp, West Henrietta, NY USA
[5] IGC Consulting, New York, NY USA
基金
美国国家科学基金会;
关键词
soft contact lens; edge-thickness; optical coherence tomography; microscopy; optical metrology; TFOS INTERNATIONAL WORKSHOP; COHERENCE TOMOGRAPHY; IN-VIVO; HIGH-SPEED; DISCOMFORT; MICROSCOPY; EPITHELIUM; QUALITY; VISION; DESIGN;
D O I
10.1097/OPX.0000000000000892
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the edge shape of soft contact lenses using Gabor-Domain Optical Coherence Microscopy (GD-OCM) with a 2-mu m imaging resolution in three dimensions and to generate edge-thickness profiles at different distances from the edge tip of soft contact lenses. Methods. A high-speed custom-designed GD-OCM system was used to produce 3D images of the edge of an experimental soft contact lens (Bausch + Lomb, Rochester, NY) in four different configurations: in air, submerged into water, submerged into saline with contrast agent, and placed onto the cornea of a porcine eyeball. An algorithm to compute the edge-thickness was developed and applied to cross-sectional images. The proposed algorithm includes the accurate detection of the interfaces between the lens and the environment, and the correction of the refraction error. Results. The sharply defined edge tip of a soft contact lens was visualized in 3D. Results showed precise thickness measurement of the contact lens edge profile. Fifty cross-sectional image frames for each configuration were used to test the robustness of the algorithm in evaluating the edge-thickness at any distance from the edge tip. The precision of the measurements was less than 0.2 mu m. Conclusions. The results confirmed the ability of GD-OCM to provide high-definition images of soft contact lens edges. As a nondestructive, precise, and fast metrology tool for soft contact lens measurement, the integration of GD-OCMin the design and manufacturing of contact lenses will be beneficial for further improvement in edge design and quality control. In the clinical perspective, the in vivo evaluation of the lens fitted onto the cornea will advance our understanding of how the edge interacts with the ocular surface. The latter will provide insights into the impact of long-term use of contact lenses on the visual performance.
引用
收藏
页码:987 / 996
页数:10
相关论文
共 50 条
  • [11] EVALUATION OF CORNEAL THICKNESS INDUCED BY HARD AND SOFT CONTACT-LENS WEAR
    ELHAGE, SG
    HUGHES, CC
    SCHAUER, KR
    JARRELL, RL
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1972, 49 (11): : 973 - +
  • [12] EFFECTS OF CONTACT LENS THICKNESS
    WILLIAMS, CE
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1967, 44 (09): : 591 - &
  • [13] CONTACT LENS EDGE FINISHING
    BOYD, HH
    EYE EAR NOSE AND THROAT MONTHLY, 1966, 45 (11): : 70 - &
  • [14] Optical quality and visual performance in toric soft contact lens wears
    Koh, Shizuka
    Maeda, Naoyuki
    Terao, Misaki
    Maeda, Hiroko
    Kosaki, Ryo
    Kozaki, Jun
    Nishida, Kohji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [15] SOFT CONTACT LENS IN MEDICINE
    Taranukha, O. A.
    WORLD OF MEDICINE AND BIOLOGY, 2015, 51 (03): : 163 - 172
  • [16] Conjunctivalization of a soft contact lens
    Bettich, Z.
    Benchekroun, S.
    El Moize, Z.
    Cherkaoui, L. O.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2019, 42 (01): : 86 - 88
  • [17] Measurement of corneal epithelial thickness using optical coherence tomography in response to hypoxia induced by soft contact lens and eye closure
    Wang, Jianhua
    Fonn, Desmond
    Simpson, Trefford L.
    Jones, Lyndon
    Optometry and Vision Science, 2000, 77 (12 SUPPL.)
  • [18] SUBJECTIVE AND OBJECTIVE ASSESSMENT OF SOFT BIFOCAL CONTACT-LENS PERFORMANCE
    BULLIMORE, MA
    JACOBS, RJ
    OPTOMETRY AND VISION SCIENCE, 1993, 70 (06) : 469 - 475
  • [19] Central corneal thickness after hypoxia in healthy humans and in soft contact lens wearers
    Katsoulis, K
    Goldblum, D
    Frueh, BE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U579 - U579
  • [20] Influence of extended soft contact lens wear on the comparative measurement of central corneal thickness
    Lattimore, MR