The effect of soft contact lens thickness in visual function after intracorneal ring segments surgery

被引:5
|
作者
Carracedo, G. [1 ]
Canales, J. [1 ]
Gonzalez, P. [1 ]
Recchioni, A. [1 ]
Carpena-Torres, C. [1 ]
Carballo-Alvarez, J. [1 ]
机构
[1] Univ Complutense Madrid, Sch Opt, Dept Opt Optometry & Vis 2, C Arcos Jalon 118, Madrid 28032, Spain
来源
CONTACT LENS & ANTERIOR EYE | 2018年 / 41卷 / 02期
关键词
Keratoconus; Intracorneal rings; Visual function; Contact lenses; ANTERIOR CORNEAL ABERRATIONS; HIGHER-ORDER ABERRATIONS; QUALITY-OF-LIFE; OPTICAL-QUALITY; KERATOCONUS PATIENTS; TEAR-FILM; PERFORMANCE; REPEATABILITY; IMPLANTATION; POSTERIOR;
D O I
10.1016/j.clae.2017.09.020
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To study the influence of soft contact lens (SCL) central thickness and material in keratoconus on visual function after intracorneal ring segment (ICRS) surgery. Methods: A pilot, experimental, prospective, cross-sectional and double-blind study was performed. Fourteen keratoconus patients with age range of 34.75 +/- 9.22 years (7 males and 7 females) with ICRS implanted were involved in the study. Two different SCL materials [Hioxifilcon A (G-5X/p-GMA/HEMA) and Lucifilcon A (silicone- hydrogel)] with four different central thicknesses (0.1, 0.2, 0.3 and 0.4 mm) were fitted in one eye per patient, selected randomly. High and low corrected distance visual acuity (CDVA) and contrast sensitivity (CS), corneal topography and corneal and total aberrometry were measured. Results: Corneal spherical like, coma like and root mean square (RMS) decreased significantly for 0.3 and 0.4 mm in both SCL materials (p < 0.05). Total RMS decreased significantly for 0.4 mm with both SCL materials (p < 0.05). High and low CDVA improved for 0.4 mm of thickness for both materials (p < 0.05). Statistically increasing were found in all thicknesses studied for CS in both materials (p < 0.05). Conclusion: A central thickness of the SCL equal or superior to 0.4 mm seems to decrease the ocular high order aberration (HOA) and to improve the visual function in keratoconus patients implanted with ICRS. However, the modulus of rigidity of the SCL would not influence the HOA correction.
引用
收藏
页码:180 / 186
页数:7
相关论文
共 50 条
  • [1] Scleral lens after intracorneal ring segments in patients with keratoconus
    Rathi, Varsha M.
    Mandathara, Preeji S.
    Dumpati, Srikanth
    Sangwan, Virender S.
    CONTACT LENS & ANTERIOR EYE, 2018, 41 (02): : 234 - 237
  • [2] Intracorneal Ring Segments and Phakic Intraocular Lens
    Navas, Alejandro
    Ramirez-Miranda, Arturo
    Graue-Hernandez, Enrique O.
    Gomez-Bastar, Arturo
    Ramirez-Luquin, Tito
    JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (08) : 555 - 556
  • [3] Asymmetric Thickness Intracorneal Ring Segments for Keratoconus
    Baptista, Pedro Manuel
    Marques, Joao Heitor
    Neves, Miguel Mesquita
    Gomes, Miguel
    Oliveira, Luis
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 4415 - 4421
  • [4] Effect of Conus Eccentricity on Visual Outcomes After Intracorneal Ring Segments Implantation in Keratoconus
    Gatzioufas, Zisis
    Panos, Georgios D.
    Elalfy, Mohamed
    Khine, Aye
    Hamada, Samer
    Lake, Damian
    Kozeis, Nikos
    Balidis, Miltos
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (03) : 196 - 200
  • [5] Contact lenses fitting after intracorneal ring segments implantation in keratoconus
    Moreira, Luciane Bugmann
    Canto Bardal, Ricardo Augustho
    Crisigiovanni, Leila Roberta
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2013, 76 (04) : 215 - 217
  • [6] Patient Satisfaction and Visual Function after combination Intracorneal Ring Segments and Corneal Collagen Crosslinking
    Chung, Daniel
    Greenstein, Steven
    Hersh, Peter
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [7] Intracorneal Ring Segments and Phakic Intraocular Lens Reply
    Cakir, Hanefi
    Utine, Canan Asli
    JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (08) : 556 - 556
  • [8] Visual Outcome after Implantation of Intracorneal Ring Segments for Pellucid Marginal Degeneration
    Jabbarvand, Mahmood
    Amanzadeh, Kazem
    Rahimi, Firoozeh
    Kheirkhah, Ahmad
    Hashemi, Hassan
    IRANIAN JOURNAL OF OPHTHALMOLOGY, 2010, 22 (01): : 41 - 45
  • [9] Intracorneal ring segments after laser in situ keratomileusis
    Güell, JL
    Velasco, F
    Sánchez, SI
    Gris, O
    Garcia-Rojas, M
    JOURNAL OF REFRACTIVE SURGERY, 2004, 20 (04) : 349 - 355
  • [10] Corneal infections after implantation of intracorneal ring segments
    Hofling-Lima, AL
    Branco, BC
    Romano, AC
    Campos, MQS
    Moreira, H
    Miranda, D
    Kwitko, S
    de Freitas, D
    Casanova, F
    Sartori, M
    Schor, P
    Souza, LB
    CORNEA, 2004, 23 (06) : 547 - 549