The effect of soft contact lens thickness in visual function after intracorneal ring segments surgery

被引:5
|
作者
Carracedo, G. [1 ]
Canales, J. [1 ]
Gonzalez, P. [1 ]
Recchioni, A. [1 ]
Carpena-Torres, C. [1 ]
Carballo-Alvarez, J. [1 ]
机构
[1] Univ Complutense Madrid, Sch Opt, Dept Opt Optometry & Vis 2, C Arcos Jalon 118, Madrid 28032, Spain
来源
CONTACT LENS & ANTERIOR EYE | 2018年 / 41卷 / 02期
关键词
Keratoconus; Intracorneal rings; Visual function; Contact lenses; ANTERIOR CORNEAL ABERRATIONS; HIGHER-ORDER ABERRATIONS; QUALITY-OF-LIFE; OPTICAL-QUALITY; KERATOCONUS PATIENTS; TEAR-FILM; PERFORMANCE; REPEATABILITY; IMPLANTATION; POSTERIOR;
D O I
10.1016/j.clae.2017.09.020
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To study the influence of soft contact lens (SCL) central thickness and material in keratoconus on visual function after intracorneal ring segment (ICRS) surgery. Methods: A pilot, experimental, prospective, cross-sectional and double-blind study was performed. Fourteen keratoconus patients with age range of 34.75 +/- 9.22 years (7 males and 7 females) with ICRS implanted were involved in the study. Two different SCL materials [Hioxifilcon A (G-5X/p-GMA/HEMA) and Lucifilcon A (silicone- hydrogel)] with four different central thicknesses (0.1, 0.2, 0.3 and 0.4 mm) were fitted in one eye per patient, selected randomly. High and low corrected distance visual acuity (CDVA) and contrast sensitivity (CS), corneal topography and corneal and total aberrometry were measured. Results: Corneal spherical like, coma like and root mean square (RMS) decreased significantly for 0.3 and 0.4 mm in both SCL materials (p < 0.05). Total RMS decreased significantly for 0.4 mm with both SCL materials (p < 0.05). High and low CDVA improved for 0.4 mm of thickness for both materials (p < 0.05). Statistically increasing were found in all thicknesses studied for CS in both materials (p < 0.05). Conclusion: A central thickness of the SCL equal or superior to 0.4 mm seems to decrease the ocular high order aberration (HOA) and to improve the visual function in keratoconus patients implanted with ICRS. However, the modulus of rigidity of the SCL would not influence the HOA correction.
引用
收藏
页码:180 / 186
页数:7
相关论文
共 50 条
  • [31] Central corneal thickness after hypoxia in healthy humans and in soft contact lens wearers
    Katsoulis, K
    Goldblum, D
    Frueh, BE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U579 - U579
  • [32] Intracorneal ring segments for iatrogenic keratectasia after laser in situ keratomileusis or photorefractive keratectomy
    Lovisolo, CF
    Fleming, JF
    JOURNAL OF REFRACTIVE SURGERY, 2002, 18 (05) : 535 - 541
  • [33] Pre-Descemetic Placement of Intracorneal Ring Segments for Keratoconus after Mechanical Implantation
    Yahya, Faady
    Pruente, Christian F.
    Scholl, Hendrik P. N.
    Gatzioufas, Zisis
    CASE REPORTS IN OPHTHALMOLOGY, 2021, 12 (03): : 940 - 943
  • [34] Evaluation of central corneal thickness after cataract surgery, penetrating keratoplasty and long-term soft contact lens wear
    Sel, Saadettin
    Trau, Stefanie
    Knak, Matthias
    Kalinski, Thomas
    Kaiser, Delia
    Kruse, Friedrich E.
    Huchzermeyer, Cord
    Duncker, Gernot I. W.
    Paulsen, Friedrich
    Auffarth, Gerd U.
    Nass, Norbert
    CONTACT LENS & ANTERIOR EYE, 2013, 36 (05): : 238 - 242
  • [35] Intracorneal Ring Segment in Keratoconus: A Model to Predict Visual Changes Induced by the Surgery
    Pena-Garcia, Pablo
    Vega-Estrada, Alfredo
    Barraquer, Rafael I.
    Burguera-Gimenez, Neus
    Alio, Jorge L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (13) : 8447 - 8457
  • [36] Corneal crosslinking and intracorneal ring segments for keratoconus: A randomized study of concurrent versus sequential surgery
    Hersh, Peter S.
    Issa, Reda
    Greenstein, Steven A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 830 - 839
  • [37] Intracorneal Ring Segments Implantation Outcomes Using Two Different Manufacturers' Nomograms for Keratoconus Surgery
    Rocha, Guillienne
    Pinto Silva, Ldmila Naschnento
    Oliveira Borges Chaves, Luis Fernando
    Bertino, Pedro
    Torquetti, Leonardo
    de Sousa, Luciene Barbosa
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (10) : 673 - +
  • [38] Feasibility of custom-made hydrogel contact lenses in keratoconus with previous implantation of intracorneal ring segments
    Jose Fernandez-Velazquez, Fernando
    Jose Fernandez-Fidalgo, Maria
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (05): : 351 - 356
  • [39] Contact lens fitting for visual rehabilitation in patients after open globe surgery
    Grünauer-Kloevekorn, C
    Habermann, A
    Wilhelm, F
    Duncker, GIW
    Hammer, T
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2004, 221 (08) : 652 - 657
  • [40] Visual quality with corneo-scleral contact lenses after intracorneal ring segment (ICRS) implantation for keratoconus management
    Carlos Montalt, Juan
    Porcar, Esteban
    Espana-Gregori, Enrique
    Peris-Martinez, Cristina
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (01): : 111 - 116