Validation of the fully automated Pangao PG-800B68 upper-arm device according to the European Society of Hypertension International Protocol revision 2010

被引:0
|
作者
Yao, Rui [1 ]
Du, You-You [1 ]
Li, Ya-Peng [1 ]
Zhang, Yan-Zhou [1 ]
Chen, Qing-Hua [1 ]
Zhao, Luo-Sha [1 ]
Li, Ling [1 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Cardiol, Zhengzhou 450052, Peoples R China
关键词
blood pressure measurement; European Society of Hypertension; hypertension; validation; BLOOD-PRESSURE;
D O I
10.1097/MBP.0000000000000111
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
ObjectiveThis study aimed to validate the fully automated Pangao PG-800B68 upper-arm device according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010.Materials and methodsSequential measurements of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were obtained in 33 participants using the standard mercury sphygmomanometer and the test device. The ESH-IP revision 2010 was followed precisely and 99 pairings of test device and reference blood pressure measurements were obtained for analysis.ResultsThe number of blood pressure differences within 5, 10, and 15mmHg was 76, 95, and 98, respectively, for SBP and 79, 96, and 99, respectively, for DBP. The device achieved all the required criteria of the ESH-IP revision 2010 with a device-observer difference of -0.034.64mmHg for SBP and -0.64 +/- 4.50mmHg for DBP.ConclusionAccording to the validation results on the basis of the ESH-IP revision 2010, the Pangao PG-800B68 can be recommended for clinical use and self-measurement in adults.
引用
收藏
页码:221 / 224
页数:4
相关论文
共 50 条
  • [1] Validation of the Pangao PG-800B5 for clinical use and self-measurement according to the European Society of Hypertension International Protocol revision 2010
    Chen, Wan
    Zeng, Zhaolin
    Li, Lizhi
    Wan, Xiaofen
    Wan, Yi
    BLOOD PRESSURE MONITORING, 2014, 19 (05) : 302 - 305
  • [2] Validation of the Pangao PG-800B26 upper arm blood pressure monitor in the general population according to the European Society of Hypertension and the British Hypertension Society protocols
    Chen, Liang
    Li, Jiyu
    Wen, Jing
    Guo, Changfeng
    Zhang, Jingying
    Yu, Zhen
    BLOOD PRESSURE MONITORING, 2018, 23 (01) : 41 - 44
  • [3] Validation of the Pangao PG-800A11 wrist device assessed according to the European Society of Hypertension and the British Hypertension Society protocols
    Xie, Peigen
    Wang, Yanling
    Xu, Xiaoying
    Huang, Fei
    Pan, Jingru
    BLOOD PRESSURE MONITORING, 2015, 20 (02) : 108 - 111
  • [4] Validation of the SEJOY BP-1307 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Lei, Lei
    Chen, Yi
    Chen, Qi
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2017, 22 (06) : 371 - 374
  • [5] Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Zhang, Lu
    Kang, Yuan-Yuan
    Zeng, Wei-Fang
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2015, 20 (02) : 104 - 107
  • [6] Validation of the BPUMP BF1112 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Chen, Qi
    Kang, Yuan-Yuan
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2017, 22 (02) : 105 - 108
  • [7] Validation of the AVITA BPM64 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Kang, Yuan-Yuan
    Chen, Qi
    Liu, Chang-Yuan
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2018, 23 (01) : 45 - 48
  • [8] Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Huang, Jinhua
    Li, Zhijie
    Li, Guimei
    Liu, Zhaoying
    BLOOD PRESSURE MONITORING, 2015, 20 (05) : 283 - 285
  • [9] Validation of the HL868ED upper-arm blood pressure monitor for clinical use and self-measurement according to the European Society of Hypertension International Protocol revision 2010
    Zhang Wei
    Lei Lei
    Li Yan
    Wang Ji-Guang
    BLOOD PRESSURE MONITORING, 2020, 25 (01) : 53 - 57
  • [10] Validation of the iHealth BP3 upper-arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010
    Chen, Can
    Shang, Fujun
    Wang, Jiepin
    Chen, Jianghong
    Ji, Na
    Wan, Yi
    BLOOD PRESSURE MONITORING, 2012, 17 (06) : 253 - 256