Validation of the fully automated Pangao PG-800B68 upper-arm device according to the European Society of Hypertension International Protocol revision 2010

被引:0
|
作者
Yao, Rui [1 ]
Du, You-You [1 ]
Li, Ya-Peng [1 ]
Zhang, Yan-Zhou [1 ]
Chen, Qing-Hua [1 ]
Zhao, Luo-Sha [1 ]
Li, Ling [1 ]
机构
[1] Zhengzhou Univ, Affiliated Hosp 1, Dept Cardiol, Zhengzhou 450052, Peoples R China
关键词
blood pressure measurement; European Society of Hypertension; hypertension; validation; BLOOD-PRESSURE;
D O I
10.1097/MBP.0000000000000111
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
ObjectiveThis study aimed to validate the fully automated Pangao PG-800B68 upper-arm device according to the European Society of Hypertension International Protocol (ESH-IP) revision 2010.Materials and methodsSequential measurements of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were obtained in 33 participants using the standard mercury sphygmomanometer and the test device. The ESH-IP revision 2010 was followed precisely and 99 pairings of test device and reference blood pressure measurements were obtained for analysis.ResultsThe number of blood pressure differences within 5, 10, and 15mmHg was 76, 95, and 98, respectively, for SBP and 79, 96, and 99, respectively, for DBP. The device achieved all the required criteria of the ESH-IP revision 2010 with a device-observer difference of -0.034.64mmHg for SBP and -0.64 +/- 4.50mmHg for DBP.ConclusionAccording to the validation results on the basis of the ESH-IP revision 2010, the Pangao PG-800B68 can be recommended for clinical use and self-measurement in adults.
引用
收藏
页码:221 / 224
页数:4
相关论文
共 50 条
  • [21] Validation of the custo screen 400 ambulatory blood pressure-monitoring device according to the European Society of Hypertension International Protocol revision 2010
    Bramlage, Peter
    Deutsch, Cornelia
    Krueger, Ralf
    Wolf, Andreas
    Mueller, Peter
    Zwingers, Thomas
    Beime, Beate
    Mengden, Thomas
    VASCULAR HEALTH AND RISK MANAGEMENT, 2014, 10 : 303 - 309
  • [22] Validation of the Hingmed WBP-02A device for ambulatory blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Fania, Claudio
    Vezzu, Leonardo
    Lazzaretto, Ilaria
    Palatini, Paolo
    BLOOD PRESSURE MONITORING, 2019, 24 (03) : 151 - 154
  • [23] Validation of the Medipro MediCare 100f upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010
    Yi, Jun
    Wan, Yi
    Pan, Feng
    Yu, Xiaorong
    Zhao, Huadong
    Shang, Fujun
    Xu, Yongyong
    BLOOD PRESSURE MONITORING, 2011, 16 (04) : 197 - 199
  • [24] Validation of the iHealth BP5 wireless upper arm blood pressure monitor for self-measurement according to the European Society of Hypertension International Protocol revision 2010
    Shang, Fujun
    Zhu, Yizheng
    Zhu, Zhenlai
    Liu, Lei
    Wan, Yi
    BLOOD PRESSURE MONITORING, 2013, 18 (05) : 278 - 281
  • [25] Validation of noninvasive oscillometric blood pressure 2020 up pressure upper arm blood pressure monitoring technology according to the European Society of Hypertension International Protocol revision 2010
    Reshetnik, Alexander
    Gohlisch, Christopher
    Abou-Dakn, Michael
    Toelle, Markus
    Zidek, Walter
    van der Giet, Markus
    BLOOD PRESSURE MONITORING, 2019, 24 (02) : 99 - 101
  • [26] Validation of the custo screen pediatric blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010
    Beime, Beate
    Deutsch, Cornelia
    Krueger, Ralf
    Wolf, Andreas
    Mueller, Peter
    Hammel, Gertrud
    Bramlage, Peter
    EUROPEAN JOURNAL OF PEDIATRICS, 2017, 176 (05) : 573 - 580
  • [27] Validation of the custo screen pediatric blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010
    Beate Beime
    Cornelia Deutsch
    Ralf Krüger
    Andreas Wolf
    Peter Müller
    Gertrud Hammel
    Peter Bramlage
    European Journal of Pediatrics, 2017, 176 : 573 - 580
  • [28] Validation of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Kang, Yuan-Yuan
    Zeng, Wei-Fang
    Liu, Ming
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2014, 19 (01) : 46 - 49
  • [29] Validation of the Thermor BIOS BD215 device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010
    Benetti, Elisabetta
    Fania, Claudio
    Hernandez, Veronica Marquez
    Palatini, Paolo
    BLOOD PRESSURE MONITORING, 2014, 19 (03) : 176 - 179
  • [30] Validation of the A&D UM-201 device for office blood pressure measurement according to the European Society of Hypertension International Protocol Revision 2010
    Fania, Claudio
    Albertini, Federica
    Palatini, Paolo
    BLOOD PRESSURE MONITORING, 2017, 22 (04) : 234 - 237