Radiation dose reduction for coronary artery calcium scoring at 320-detector CT with adaptive iterative dose reduction 3D

被引:19
|
作者
Tatsugami, Fuminari [1 ]
Higaki, Toru [1 ]
Fukumoto, Wataru [1 ]
Kaichi, Yoko [1 ]
Fujioka, Chikako [2 ]
Kiguchi, Masao [2 ]
Yamamoto, Hideya [3 ]
Kihara, Yasuki [3 ]
Awai, Kazuo [1 ]
机构
[1] Hiroshima Univ, Dept Diagnost Radiol, Minami Ku, Hiroshima 7348551, Japan
[2] Hiroshima Univ, Dept Radiol, Minami Ku, Hiroshima 7348551, Japan
[3] Hiroshima Univ, Dept Cardiovasc Med, Minami Ku, Hiroshima 7348551, Japan
来源
关键词
Coronary artery calcium; Iterative reconstruction; Dose reduction; 320-detector CT scanner; MULTIDETECTOR ROW CT; ULTRAFAST COMPUTED-TOMOGRAPHY; TRIGGERED 64-SLICE CT; INTERSCAN VARIABILITY; HEART-ASSOCIATION; CARDIAC CT; QUANTIFICATION; ANGIOGRAPHY; RECONSTRUCTION; REPRODUCIBILITY;
D O I
10.1007/s10554-015-0637-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the possibility of reducing the radiation dose for coronary artery calcium (CAC) scoring by using adaptive iterative dose reduction 3D (AIDR 3D) on a 320-detector CT scanner. Fifty-four patients underwent routine- and low-dose CT for CAC scoring. Low-dose CT was performed at one-third of the tube current used for routine-dose CT. Routine-dose CT was reconstructed with filtered back projection (FBP) and low-dose CT was reconstructed with AIDR 3D. We compared the calculated Agatston-, volume-, and mass scores of these images. The overall percentage difference in the Agatston-, volume-, and mass scores between routine- and low-dose CT studies was 15.9, 11.6, and 12.6 %, respectively. There were no significant differences in the routine- and low-dose CT studies irrespective of the scoring algorithms applied. The CAC measurements of both imaging modalities were highly correlated with respect to the Agatston- (r = 0.996), volume- (r = 0.996), and mass score (r = 0.997; p < 0.001, all); the Bland-Altman limits of agreement scores were -37.4 to 51.4, -31.2 to 36.4 and -30.3 to 40.9 %, respectively, suggesting that AIDR 3D was a good alternative for FBP. The mean effective radiation dose for routine- and low-dose CT was 2.2 and 0.7 mSv, respectively. The use of AIDR 3D made it possible to reduce the radiation dose by 67 % for CAC scoring without impairing the quantification of coronary calcification.
引用
收藏
页码:1045 / 1052
页数:8
相关论文
共 50 条
  • [11] Radiation Dose of Second-Generation 320-Detector Row CT
    Qian, Xue-jiang
    RADIOLOGY, 2013, 268 (03) : 927 - 928
  • [12] Radiation Dose Reduction at Coronary Artery Calcium Scoring by Using a Low Tube Current Technique and Hybrid Iterative Reconstruction
    Matsuura, Noriaki
    Urashima, Masaki
    Fukumoto, Wataru
    Sunamori, Hiroshi
    Tatsugami, Fuminari
    Toyota, Naoyuki
    Awai, Kazuo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (01) : 119 - 124
  • [13] The impact of CT radiation dose reduction and iterative reconstruction algorithms from four different vendors on coronary calcium scoring
    Willemink, Martin J.
    Takx, Richard A. P.
    de Jong, Pim A.
    Budde, Ricardo P. J.
    Bleys, Ronald L. A. W.
    Das, Marco
    Wildberger, Joachim E.
    Prokop, Mathias
    Buls, Nico
    de Mey, Johan
    Schilham, Arnold M. R.
    Leiner, Tim
    EUROPEAN RADIOLOGY, 2014, 24 (09) : 2201 - 2212
  • [14] The impact of CT radiation dose reduction and iterative reconstruction algorithms from four different vendors on coronary calcium scoring
    Martin J. Willemink
    Richard A. P. Takx
    Pim A. de Jong
    Ricardo P. J. Budde
    Ronald L. A. W. Bleys
    Marco Das
    Joachim E. Wildberger
    Mathias Prokop
    Nico Buls
    Johan de Mey
    Arnold M. R. Schilham
    Tim Leiner
    European Radiology, 2014, 24 : 2201 - 2212
  • [15] Radiation dose in coronary artery angiography with 320-detector row CT and its diagnostic accuracy: comparison with 64-detector row CT
    Zhang, T.
    Luo, Z. -R.
    Wang, D.
    Han, D.
    Bai, J-Q
    Meng, X. -W.
    Shen, B. -Z.
    MINERVA MEDICA, 2011, 102 (04) : 249 - 259
  • [16] Dose reduction at CT of the lumbar spine using a 320-detector row scanner: initial results
    Gervaise, A.
    Louis, M.
    Batch, T.
    Loeuille, D.
    Noel, A.
    Guillemin, F.
    Blum, A.
    JOURNAL DE RADIOLOGIE, 2010, 91 (7-8): : 779 - 785
  • [17] Initial Experience With Adaptive Iterative Dose Reduction 3D to Reduce Radiation Dose in Computed Tomographic Urography
    Juri, Hiroshi
    Matsuki, Mitsuru
    Itou, Yasushi
    Inada, Yuki
    Nakai, Go
    Azuma, Haruhito
    Narumi, Yoshifumi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (01) : 52 - 57
  • [18] The Impact of Different Levels of Adaptive Iterative Dose Reduction 3D on Image Quality of 320-Row Coronary CT Angiography: A Clinical Trial
    Feger, Sarah
    Rief, Matthias
    Zimmermann, Elke
    Martus, Peter
    Schuijf, Joanne Desiree
    Blobel, Jrog
    Richter, Felicitas
    Dewey, Marc
    PLOS ONE, 2015, 10 (05):
  • [19] Radiation dose and potential for radiation dose reduction at coronary calcium scoring with 16-slice multidetector-row CT
    Das, M
    Martensen, JM
    Schmidt, B
    Nawfel, RD
    Zou, KH
    Yucel, EK
    Schoepf, UJ
    CIRCULATION, 2003, 108 (17) : 529 - 529
  • [20] Finding the optimal dose reduction and iterative reconstruction level for coronary calcium scoring
    Willemink, Martin J.
    den Harder, Annemarie M.
    Foppen, Wouter
    Schilham, Arnold M. R.
    Rienks, Rienk
    Laufer, Eduard M.
    Nieman, Koen
    de Jong, Pim A.
    Budde, Ricardo P. J.
    Nathoe, Hendrik M.
    Leiner, Tim
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (01) : 69 - 75