Reevaluation of intrapartum fetal monitoring using fetal oximetry: A review

被引:4
|
作者
Uchida, Toshiyuki [1 ]
Kanayama, Naohiro [1 ]
Kawai, Kenta [1 ]
Mukai, Mari [1 ]
Suzuki, Kazunao [1 ]
Itoh, Hiroaki [1 ]
Niwayama, Masatsugu [2 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Obstet & Gynecol, Hamamatsu, Shizuoka, Japan
[2] Shizuoka Univ, Dept Elect & Elect Engn, Hamamatsu, Shizuoka, Japan
基金
日本学术振兴会;
关键词
examiner's mounting probe; fetal monitoring; fetal pulse oximetry; near-infrared spectroscopy; tissue oximetry; TISSUE OXYGEN-SATURATION; PULSE OXIMETRY; CONTROLLED-TRIAL; LABOR; COMPLICATION; ACCURACY; DELIVERY; MULTICENTER; MANAGEMENT; 2ND-STAGE;
D O I
10.1111/jog.13761
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim Although several studies reported the measurement of fetal oxygen saturation using fetal pulse oximetry (FPO) for evaluation of the fetal intrapartum condition, a systematic review of the seven randomized controlled trials (RCTs) provided no evidence to support FPO for intrapartum fetal monitoring. In the present review, we re-evaluate an overview for the use of FPO and seven RCTs of FPO. Methods Results We reviewed numerous previous reports on FPO and seven RCTs of intrapartum FPO. RCTs were conducted with the main outcome measure being a reduction in the cesarean section rate. The largest trial with 5341 entries failed to show any reduction. The negative result from this RCT may be explained by the use of a different cutoff value for fetal oxygen saturation compared to the other RCT; in addition, there were differences in the indications for cesarean section due to dystocia and in the definition of non-reassuring fetal status (NRFS). An abnormal FPO value, defined as the fetal oxygen saturation value <30% for at least 10 min, is useful for making a diagnosis of fetal acidosis. A newly developed device, an examiner's finger-mounted tissue oximetry, accurately measures tissue oxygen saturation while overcoming the drawbacks of FPO, such as infection risk and slipping off of the sensor during descent of the fetal head. Conclusion FPO (including the new device) with fetal heart rate monitoring in selected cases of NRFS may reduce the cesarean section rate.
引用
收藏
页码:2127 / 2134
页数:8
相关论文
共 50 条
  • [21] INTRAPARTUM FETAL PULSE OXIMETRY IN THE PRESENCE OF FETAL CARDIAC-ARRHYTHMIA
    DILDY, GA
    LOUCKS, CA
    CLARK, SL
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1993, 169 (06) : 1609 - 1611
  • [22] Evaluation of intrapartum fetal well-being by fetal pulse oximetry
    Amano, K
    Hirano, S
    Nishijima, M
    LABOR AND DELIVERY, 1998, : 396 - 399
  • [23] INTRAPARTUM FETAL PULSE OXIMETRY - PRESENT AND FUTURE
    ELCHALAL, U
    WEISSMAN, A
    ABRAMOV, Y
    ABRAMOV, D
    WEINSTEIN, D
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 1995, 50 (02) : 131 - 137
  • [24] FIGO consensus guidelines on intrapartum fetal monitoring: Physiology of fetal oxygenation and the main goals of intrapartum fetal monitoring
    Ayres-de-Campos, Diogo
    Arulkumaran, Sabaratnam
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2015, 131 (01) : 5 - 8
  • [25] Intrapartum fetal monitoring today
    Schwartz, N
    Young, BK
    JOURNAL OF PERINATAL MEDICINE, 2006, 34 (02) : 99 - 107
  • [26] INTRAPARTUM FETAL MONITORING FOR ALL
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1976, 2 (6050): : 1466 - 1466
  • [27] Update on intrapartum fetal monitoring
    Rashid, M
    Rashid, RS
    ANNALS OF SAUDI MEDICINE, 2003, 23 (1-2) : 43 - 47
  • [28] The efficacy of intrapartum fetal surveillance when fetal pulse oximetry is added to cardiotocography
    vandenBerg, PP
    Dildy, GA
    Luttkus, A
    Mason, GC
    Harvey, CJ
    Nijhuis, JG
    Jongsma, HW
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1997, 72 : S67 - S71
  • [29] Monitoring Fetal Electroencephalogram Intrapartum: A Systematic Literature Review
    Castel, Aude
    Frank, Yael S.
    Feltner, John
    Karp, Floyd B.
    Albright, Catherine M.
    Frasch, Martin G.
    FRONTIERS IN PEDIATRICS, 2020, 8
  • [30] INTRAPARTUM FETAL MONITORING - FOREWORD
    PETRIE, RH
    CLINICAL OBSTETRICS AND GYNECOLOGY, 1986, 29 (01): : 1 - 1