Reevaluation of intrapartum fetal monitoring using fetal oximetry: A review

被引:4
|
作者
Uchida, Toshiyuki [1 ]
Kanayama, Naohiro [1 ]
Kawai, Kenta [1 ]
Mukai, Mari [1 ]
Suzuki, Kazunao [1 ]
Itoh, Hiroaki [1 ]
Niwayama, Masatsugu [2 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Obstet & Gynecol, Hamamatsu, Shizuoka, Japan
[2] Shizuoka Univ, Dept Elect & Elect Engn, Hamamatsu, Shizuoka, Japan
基金
日本学术振兴会;
关键词
examiner's mounting probe; fetal monitoring; fetal pulse oximetry; near-infrared spectroscopy; tissue oximetry; TISSUE OXYGEN-SATURATION; PULSE OXIMETRY; CONTROLLED-TRIAL; LABOR; COMPLICATION; ACCURACY; DELIVERY; MULTICENTER; MANAGEMENT; 2ND-STAGE;
D O I
10.1111/jog.13761
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim Although several studies reported the measurement of fetal oxygen saturation using fetal pulse oximetry (FPO) for evaluation of the fetal intrapartum condition, a systematic review of the seven randomized controlled trials (RCTs) provided no evidence to support FPO for intrapartum fetal monitoring. In the present review, we re-evaluate an overview for the use of FPO and seven RCTs of FPO. Methods Results We reviewed numerous previous reports on FPO and seven RCTs of intrapartum FPO. RCTs were conducted with the main outcome measure being a reduction in the cesarean section rate. The largest trial with 5341 entries failed to show any reduction. The negative result from this RCT may be explained by the use of a different cutoff value for fetal oxygen saturation compared to the other RCT; in addition, there were differences in the indications for cesarean section due to dystocia and in the definition of non-reassuring fetal status (NRFS). An abnormal FPO value, defined as the fetal oxygen saturation value <30% for at least 10 min, is useful for making a diagnosis of fetal acidosis. A newly developed device, an examiner's finger-mounted tissue oximetry, accurately measures tissue oxygen saturation while overcoming the drawbacks of FPO, such as infection risk and slipping off of the sensor during descent of the fetal head. Conclusion FPO (including the new device) with fetal heart rate monitoring in selected cases of NRFS may reduce the cesarean section rate.
引用
收藏
页码:2127 / 2134
页数:8
相关论文
共 50 条
  • [31] RESULTS OF INTRAPARTUM FETAL MONITORING
    EDINGTON, PT
    BEARD, RW
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1975, 82 (06): : 511 - 511
  • [32] PRELIMINARY EXPERIENCE WITH INTRAPARTUM FETAL PULSE OXIMETRY IN HUMANS
    GOODLIN, RC
    OBSTETRICS AND GYNECOLOGY, 1993, 82 (02): : 314 - 314
  • [33] Fetal Sex Differences in Intrapartum Electronic Fetal Monitoring
    Porter, Anne C.
    Triebwasser, Jourdan E.
    Tuuli, Methodius
    Caughey, Aaron B.
    Macones, George A.
    Cahill, Alison G.
    AMERICAN JOURNAL OF PERINATOLOGY, 2016, 33 (08) : 786 - 790
  • [34] PRELIMINARY EXPERIENCE WITH INTRAPARTUM FETAL PULSE OXIMETRY IN HUMANS
    DILDY, GA
    CLARK, SL
    LOUCKS, CA
    OBSTETRICS AND GYNECOLOGY, 1993, 81 (04): : 630 - 635
  • [35] FETAL MONITORING WITH PULSE OXIMETRY
    JOHNSON, N
    JOHNSON, VA
    FISHER, J
    JOBBINGS, B
    BANNISTER, J
    LILFORD, RJ
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1991, 98 (01): : 36 - 41
  • [36] Intrapartum fetal pulse oximetry: Past, present, and future
    Dildy, GA
    Clark, SL
    Loucks, CA
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1996, 175 (01) : 1 - 9
  • [37] Pulse oximetry as an additional method for intrapartum fetal surveillance
    Fuhr, N
    Hopp, H
    Runkel, S
    Weitzel, H
    LABOR AND DELIVERY, 1998, : 393 - 395
  • [38] Fetal pulse oximetry: Duration of desaturation and intrapartum outcome
    Bloom, SL
    Swindle, RG
    Mcintire, DD
    Leveno, KJ
    OBSTETRICS AND GYNECOLOGY, 1999, 93 (06): : 1036 - 1040
  • [39] The fetal oxygen saturation in premature labor measured by means of intrapartum fetal pulse oximetry
    Roztocil, A
    Kucera, M
    Kachlík, P
    Ventruba, P
    WOMAN AND CHILD BEFORE, DURING AND AFTER PREGNANCY, 2001, : 349 - 354
  • [40] Fetal pulse oximetry in intrapartum management of nonreassuring fetal heart rate patterns - Reply
    Garite, TJ
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2001, 185 (03) : 771 - 772