Reevaluation of intrapartum fetal monitoring using fetal oximetry: A review

被引:4
|
作者
Uchida, Toshiyuki [1 ]
Kanayama, Naohiro [1 ]
Kawai, Kenta [1 ]
Mukai, Mari [1 ]
Suzuki, Kazunao [1 ]
Itoh, Hiroaki [1 ]
Niwayama, Masatsugu [2 ]
机构
[1] Hamamatsu Univ Sch Med, Dept Obstet & Gynecol, Hamamatsu, Shizuoka, Japan
[2] Shizuoka Univ, Dept Elect & Elect Engn, Hamamatsu, Shizuoka, Japan
基金
日本学术振兴会;
关键词
examiner's mounting probe; fetal monitoring; fetal pulse oximetry; near-infrared spectroscopy; tissue oximetry; TISSUE OXYGEN-SATURATION; PULSE OXIMETRY; CONTROLLED-TRIAL; LABOR; COMPLICATION; ACCURACY; DELIVERY; MULTICENTER; MANAGEMENT; 2ND-STAGE;
D O I
10.1111/jog.13761
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim Although several studies reported the measurement of fetal oxygen saturation using fetal pulse oximetry (FPO) for evaluation of the fetal intrapartum condition, a systematic review of the seven randomized controlled trials (RCTs) provided no evidence to support FPO for intrapartum fetal monitoring. In the present review, we re-evaluate an overview for the use of FPO and seven RCTs of FPO. Methods Results We reviewed numerous previous reports on FPO and seven RCTs of intrapartum FPO. RCTs were conducted with the main outcome measure being a reduction in the cesarean section rate. The largest trial with 5341 entries failed to show any reduction. The negative result from this RCT may be explained by the use of a different cutoff value for fetal oxygen saturation compared to the other RCT; in addition, there were differences in the indications for cesarean section due to dystocia and in the definition of non-reassuring fetal status (NRFS). An abnormal FPO value, defined as the fetal oxygen saturation value <30% for at least 10 min, is useful for making a diagnosis of fetal acidosis. A newly developed device, an examiner's finger-mounted tissue oximetry, accurately measures tissue oxygen saturation while overcoming the drawbacks of FPO, such as infection risk and slipping off of the sensor during descent of the fetal head. Conclusion FPO (including the new device) with fetal heart rate monitoring in selected cases of NRFS may reduce the cesarean section rate.
引用
收藏
页码:2127 / 2134
页数:8
相关论文
共 50 条
  • [41] Fetal pulse oximetry:: Correlation with intrapartum fetal heart rate patterns and neonatal outcome
    Tekin, Arzu
    Oezkan, Sebiha
    Caliskan, Eray
    Oezeren, Semih
    Corakci, Aydin
    Yuecesoy, Izzet
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2008, 34 (05) : 824 - 831
  • [42] System errors in intrapartum electronic fetal monitoring: A case review
    Miller, LA
    JOURNAL OF MIDWIFERY & WOMENS HEALTH, 2005, 50 (06) : 507 - 516
  • [43] Intrapartum fetal assessment - A review
    Huddleston, JF
    CLINICS IN PERINATOLOGY, 1999, 26 (03) : 549 - +
  • [44] Computerised intrapartum diagnosis of fetal hypoxia based on fetal heart rate monitoring and fetal pulse oximetry recordings utilising wavelet analysis and neural networks
    Salamalekis, E
    Thomopoulos, P
    Giannaris, D
    Salloum, I
    Vasios, G
    Prentza, A
    Koutsouris, D
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2002, 109 (10) : 1137 - 1142
  • [45] INTRAPARTUM FETAL MONITORING - MATERNAL AND FETAL MORBIDITY AND PERINATAL MORTALITY
    CHAN, WH
    PAUL, RH
    TOEWS, J
    OBSTETRICS AND GYNECOLOGY, 1973, 41 (01): : 7 - 13
  • [46] Intrapartum electronic fetal monitoring and the identification of systemic fetal inflammation
    Aina-Mumuney, Abimbola J.
    Althaus, Janyne E.
    Henderson, Janice L.
    Blakemore, Maggie C.
    Johnson, Elizabeth A.
    Graham, Ernest M.
    JOURNAL OF REPRODUCTIVE MEDICINE, 2007, 52 (09) : 762 - 768
  • [47] INTRAPARTUM ELECTRONIC FETAL MONITORING EFFICACY
    FRIBOURG, S
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1987, 157 (04) : 1013 - 1014
  • [48] Intrapartum fetal heart rate monitoring
    不详
    OBSTETRICS AND GYNECOLOGY, 2005, 105 (05): : 1161 - 1168
  • [49] Intrapartum fetal heart rate monitoring
    Boehm, FH
    OBSTETRICS AND GYNECOLOGY CLINICS OF NORTH AMERICA, 1999, 26 (04) : 623 - +
  • [50] COMBINED INTRAPARTUM FETAL MONITORING, RESULTS
    GOESCHEN, K
    ZEITSCHRIFT FUR GEBURTSHILFE UND PERINATOLOGIE, 1992, 196 (03): : 103 - 105