The efficacy of intrapartum fetal surveillance when fetal pulse oximetry is added to cardiotocography

被引:6
|
作者
vandenBerg, PP
Dildy, GA
Luttkus, A
Mason, GC
Harvey, CJ
Nijhuis, JG
Jongsma, HW
机构
[1] UNIV HOSP, DEPT OBSTET & GYNECOL, SALT LAKE CITY, UT USA
[2] UNIV HOSP, DEPT OBSTET & GYNECOL, BERLIN, GERMANY
[3] UNIV HOSP, DEPT OBSTET & GYNECOL, LEEDS, W YORKSHIRE, ENGLAND
[4] UNIV HOSP, DEPT OBSTET & GYNECOL, GALVESTON, TX USA
关键词
intrapartum fetal surveillance; pulse oximetry; sensitivity; specificity;
D O I
10.1016/S0301-2115(97)02721-8
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To determine if oxygen saturation measurement with pulse oximetry (Spo(2)) in combination with cardiotocograghy (CTG), improves the assessment of the intrapartum fetal condition. Study Design: Four expert obstetricians individually evaluated 119 cases that were monitored during labor: during the first session the CTG data were available, and in the second session CTG and Spo(2) data were evaluated. They were instructed to indicate the need for intervention and to estimate the umbilical artery pH. Results: In the non-acidotic group (umbilical artery pH greater than or equal to 7.15, n = 112) the average(+/- S.D.) number of interventions decreased from 27(+/- 17) to 16(+/- 9) when Spo(2) was available. This reduction in number of interventions resulted in an significantly increased specificity for two referees. In the acidotic group (n = 7) the average number of interventions also decreased, from 6(+/- 2) to 4(+/- 2), and as a consequence the sensitivity decreased. The pH estimate based on CTG + Spo(2) was higher in both acidotic and non-acidotic fetuses than the estimated pH based on CTG alone. Conclusion: In this study all referees intervened less frequently when Spo(2) was used as an adjunct to CTG. This resulted in fewer unnecessary operative interventions, but may also lead to unidentified fetal acidosis. The number of acidotic newborns (n = 7) was too small, however, to draw definite conclusions. Larger studies should address the efficacy of Spo(2) in detecting fetal compromise before clinical use can be advocated. (C) 1997 Elsevier Science Ireland Ltd.
引用
收藏
页码:S67 / S71
页数:5
相关论文
共 50 条
  • [1] Intrapartum surveillance of IUGR fetuses with cardiotocography and fetal pulse oximetry
    Siristatidis, C
    Salamalekis, E
    Vitoratos, N
    Loghis, C
    Salloum, J
    Kassanos, D
    Panayotopoulos, N
    Creatsas, G
    BIOLOGY OF THE NEONATE, 2003, 83 (03): : 162 - 165
  • [2] Intrapartum cardiotocography and fetal pulse oximetry in assessing fetal hypoxia
    Leszczynska-Gorzelak, B
    Poniedzialek-Czajkowska, E
    Oleszczuk, J
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2002, 76 (01) : 9 - 14
  • [3] Pulse oximetry as an additional method for intrapartum fetal surveillance
    Fuhr, N
    Hopp, H
    Runkel, S
    Weitzel, H
    LABOR AND DELIVERY, 1998, : 393 - 395
  • [4] Fetal pulse oximetry:: clinical evaluation during intrapartum surveillance
    Kühnert, M
    Seelbach-Göbel, B
    2ND INTERNATIONAL CONGRESS ON NEW TECHNOLOGIES IN REPRODUCTIVE MEDICINE, NEONATOLOGY AND GYNECOLOGY, 1999, : 103 - 110
  • [5] Fetal pulse oximetry improves intrapartum fetal assessment
    Carrillo, J
    Insunza, A
    Latorre, R
    Mercado, M
    Cardenas, F
    Novoa, JM
    Paiva, E
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 189 (06) : S184 - S184
  • [6] The unresolved role of cardiotocography (CTG), fetal ECG (STAN) and intrapartum fetal pulse oximetry (IFPO) as diagnostic methods for fetal hypoxia
    Sholapurkar, S. L.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2014, 34 (08) : 757 - 757
  • [7] The future of intrapartum fetal pulse oximetry
    Dildy, GA
    CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2001, 13 (02) : 133 - 136
  • [8] Update on intrapartum fetal pulse oximetry
    East, CE
    Colditz, PB
    Begg, LM
    Brennecke, SP
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2002, 42 (02): : 119 - 124
  • [9] Intrapartum fetal pulse oximetry and fetal heart rate decelerations
    Puertas, A
    Navarro, M
    Velasco, R
    Montoya, E
    Miranda, JA
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2004, 85 (01) : 12 - 17
  • [10] The prediction of fetal acidosis by means of intrapartum fetal pulse oximetry
    Seelbach-Göbel, B
    Heupel, M
    Kühnert, M
    Butterwegge, M
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1999, 180 (01) : 73 - 81