Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation

被引:77
|
作者
Gerber, TC
Stratmann, BP
Kuzo, RS
Kantor, B
Morin, RL
机构
[1] Mayo Clin, Div Cardiovasc Dis, Jacksonville, FL 32224 USA
[2] Mayo Clin, Dept Diagnost Radiol, Jacksonville, FL 32224 USA
[3] Mayo Clin, Div Cardiovasc Dis, Rochester, MN USA
关键词
computed tomography coronary angiography; image quality; multidetector row computed tomography; radiation dose;
D O I
10.1097/01.rli.0000170628.69792.cb
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: We sought to examine effects of tube voltage and current on radiation dose and image quality for minimally invasive coronary angiography with a 16-slice multidetector row computed tomography (MDCT) scanner. Materials and Methods: We scanned the phantom used in the American College of Radiology Computed Tomography Accreditation Program at tube voltages of 80 and 120 kVp at 550, 650, and 750 mAs(eff), with and without a reduction in radiation dose by electrocardiographically (ECG) controlled tube current modulation (ECG pulsing). Results: Without ECG pulsing, the effective dose was 3 to 13 mSv. On average, a 50% increase in tube voltage led to increased radiation dose (215%), contrast-to-noise ratio (150%), and decreased image noise (-48%). On average, a 17% increase in mAs(eff) led to increased radiation dose (17%) and contrast-to-noise ratio (4%) and decreased image noise (-9%). Dose reduction by ECG pulsing (simulated heart rate, 70 beats per minute) was 28%. With ECG pulsing, noise in images reconstructed during ventricular systole was double that in images reconstructed during ventricular diastole. Conclusions: These quantitative findings about the relationships among scan acquisition parameters, radiation dose, and image quality have practical implications for using ECG pulsing to reduce radiation doses in MDCT coronary angiography.
引用
收藏
页码:556 / 563
页数:8
相关论文
共 50 条
  • [21] Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality
    Sei Komatsu
    Teruaki Kamata
    Atsuko Imai
    Tomoki Ohara
    Mitsuhiko Takewa
    Ryoko Ohe
    Kazuaki Miyaji
    Junichi Yoshida
    Kazuhisa Kodama
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1335 - 1340
  • [22] Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality
    Komatsu, Sei
    Kamata, Teruaki
    Imai, Atsuko
    Ohara, Tomoki
    Takewa, Mitsuhiko
    Ohe, Ryoko
    Miyaji, Kazuaki
    Yoshida, Junichi
    Kodama, Kazuhisa
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06): : 1335 - 1340
  • [23] Influence of gating phase selection on the image quality of coronary arteries in multidetector-row computed tomography
    Laskowska, Katarzyna
    Marzec, Malgorzata
    Serafin, Zbigniew
    Nawrocka, Elzbieta
    Lasek, Wladyslaw
    Wisniewska-Szmyt, Joanna
    Kubica, Jacek
    POLISH JOURNAL OF RADIOLOGY, 2005, 70 (03) : 57 - 63
  • [24] Application of Aortic Computed Tomography Angiography with Low Radiation Dose: Assessment of Image Quality and Radiation Dose
    Liu, Jianhua
    Li, Long
    Zhang, Yan
    Yuan, Qinghai
    Sun, Yong
    2012 IEEE FIFTH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTATIONAL INTELLIGENCE (ICACI), 2012, : 148 - 151
  • [25] Image quality in obese patients undergoing 256-row computed tomography coronary angiography
    Segev, Orit Lesman
    Gaspar, Tamar
    Halon, David A.
    Peled, Nathan
    Domachevsky, Liran
    Lewis, Basil S.
    Rubinshtein, Ronen
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (03): : 633 - 639
  • [26] Image quality in obese patients undergoing 256-row computed tomography coronary angiography
    Orit Lesman Segev
    Tamar Gaspar
    David A. Halon
    Nathan Peled
    Liran Domachevsky
    Basil S. Lewis
    Ronen Rubinshtein
    The International Journal of Cardiovascular Imaging, 2012, 28 : 633 - 639
  • [27] Coronary Computed Tomography Angiography With Very Low Tube Voltage Reduces Radiation Dose and Maintains Image Quality
    Daubert, Melissa A.
    Goldman, Mark
    Chen, John
    Feldmann, Eric
    Ferraro, Summer
    Hellinger, Jeffrey
    Poon, Michael
    CIRCULATION, 2011, 124 (21)
  • [28] Radiation dose and image quality in computed tomography
    Prokop, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (05): : 631 - 636
  • [29] Radiation dose and image quality with dual source computer tomography coronary angiography
    Vazquez, M.
    Tardaguila, G.
    Delgado, C.
    Calatayud, J.
    Castellon, D.
    Vilar, M.
    Sanmartin, M.
    Tardaguila, F.
    EUROPEAN HEART JOURNAL, 2011, 32 : 525 - 525
  • [30] IMAGE QUALITY AND RADIATION DOSE WITH SINGLE HEART BEAT 320 MULTIDETECTOR CT CORONARY ANGIOGRAPHY
    Williams, M. C.
    Weir, N. W.
    Mirsadraee, S.
    Scott, A. E.
    Uren, N. G.
    McKillop, G.
    Bull, R. K.
    van Beek, E. J. R.
    Reid, J. H.
    Newby, D. E.
    HEART, 2013, 99