Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation

被引:77
|
作者
Gerber, TC
Stratmann, BP
Kuzo, RS
Kantor, B
Morin, RL
机构
[1] Mayo Clin, Div Cardiovasc Dis, Jacksonville, FL 32224 USA
[2] Mayo Clin, Dept Diagnost Radiol, Jacksonville, FL 32224 USA
[3] Mayo Clin, Div Cardiovasc Dis, Rochester, MN USA
关键词
computed tomography coronary angiography; image quality; multidetector row computed tomography; radiation dose;
D O I
10.1097/01.rli.0000170628.69792.cb
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: We sought to examine effects of tube voltage and current on radiation dose and image quality for minimally invasive coronary angiography with a 16-slice multidetector row computed tomography (MDCT) scanner. Materials and Methods: We scanned the phantom used in the American College of Radiology Computed Tomography Accreditation Program at tube voltages of 80 and 120 kVp at 550, 650, and 750 mAs(eff), with and without a reduction in radiation dose by electrocardiographically (ECG) controlled tube current modulation (ECG pulsing). Results: Without ECG pulsing, the effective dose was 3 to 13 mSv. On average, a 50% increase in tube voltage led to increased radiation dose (215%), contrast-to-noise ratio (150%), and decreased image noise (-48%). On average, a 17% increase in mAs(eff) led to increased radiation dose (17%) and contrast-to-noise ratio (4%) and decreased image noise (-9%). Dose reduction by ECG pulsing (simulated heart rate, 70 beats per minute) was 28%. With ECG pulsing, noise in images reconstructed during ventricular systole was double that in images reconstructed during ventricular diastole. Conclusions: These quantitative findings about the relationships among scan acquisition parameters, radiation dose, and image quality have practical implications for using ECG pulsing to reduce radiation doses in MDCT coronary angiography.
引用
收藏
页码:556 / 563
页数:8
相关论文
共 50 条
  • [31] Sixteen-row multidetector computed tomography coronary angiography in heart transplant patients.
    Carrascosa, P
    Capunay, C
    Merletti, PG
    Garcia, M
    Vembar, M
    Lev, G
    Carrascosa, J
    Perrone, S
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 52E - 53E
  • [32] Effect of the reconstruction window obtained at the isovolumic relaxation period on the image quality in electrocardiographic-gated 16-multidetector-row computed tomography coronary angiography studies
    Kantarci, M
    Ceviz, N
    Durur, I
    Bayraktutan, U
    Karaman, A
    Alper, F
    Onbas, O
    Okur, A
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (02) : 258 - 261
  • [33] Sixteen-channel multidetector row computed tomography versus coronary angiography in a surgical view
    Plass, A
    Baumert, B
    Häussler, A
    Grünenfelder, J
    Wildermuth, S
    Eberli, FR
    Zund, G
    Genoni, M
    HEART SURGERY FORUM, 2006, 9 (02): : E572 - E578
  • [34] Radiation dose and image quality with new protocol in lower extremity computed tomography angiography
    Schicchi, Nicolo
    Fogante, Marco
    Oliva, Matteo
    Pirani, Paolo Esposto
    Agliata, Giacomo
    Giuseppetti, Gian Marco
    Giovagnoni, Andrea
    RADIOLOGIA MEDICA, 2019, 124 (03): : 184 - 190
  • [35] Radiation dose and image quality with new protocol in lower extremity computed tomography angiography
    Nicolò Schicchi
    Marco Fogante
    Matteo Oliva
    Paolo Esposto Pirani
    Giacomo Agliata
    Gian Marco Giuseppetti
    Andrea Giovagnoni
    La radiologia medica, 2019, 124 : 184 - 190
  • [36] Low Radiation Dose and High Image Quality of 320-Row Coronary Computed Tomography Angiography Using a Small Dose of Contrast Medium and Refined Scan Timing Prediction
    Shirasaka, Takashi
    Nagao, Michinobu
    Yamasaki, Yuzo
    Kojima, Tsukasa
    Kondo, Masatoshi
    Hamasaki, Hiroshi
    Kamitani, Takeshi
    Kato, Toyoyuki
    Asayama, Yoshiki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (01) : 7 - 12
  • [37] Multidetector Computed Tomography Coronary Angiography: Sublingual Nitroglycerine Improves Image Quality Significantly Because of Peripheral Coronary Vasodilatation
    Klass, Oliver
    Mutlu, Senguel
    Hohl, Kathrin
    Feuerlein, Sebastian
    Jeltsch, Martin
    Brambs, Hans-Juergen
    Hoffman, Martin H. K.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (02) : 199 - 203
  • [38] REDUCTION OF RADIATION DOSE OF 320-ROW CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY THROUGH PRIOR CORONARY CALCIUM SCANNING
    Dewey, Marc
    Zimmermann, Elke
    Wollenberg, Ulrike
    Rief, Matthias
    Greupner, Johannes
    Hamm, Bernd
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [39] Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience
    Yoneyama, Kihei
    Vavere, Andrea L.
    Cerci, Rodrigo
    Ahmed, Rukhsar
    Arai, Andrew E.
    Niinuma, Hiroyuki
    Rybicki, Frank J.
    Rochitte, Carlos E.
    Clouse, Melvin E.
    George, Richard T.
    Lima, Joao A. C.
    Arbab-Zadeh, Armin
    HEART INTERNATIONAL, 2012, 7 (02): : 51 - 56
  • [40] Achieving consistent image quality with dose optimization in 64-row multidetector computed tomography prospective ECG gated coronary calcium scoring
    Zilai Pan
    Lifang Pang
    Jianying Li
    Huan Zhang
    Wenjie Yang
    Bei Ding
    Weimin Chai
    Kemin Chen
    Weiwu Yao
    The International Journal of Cardiovascular Imaging, 2011, 27 : 611 - 617