Dual energy CT ventilation imaging after aerosol inhalation of iodinated contrast medium in rabbits

被引:6
|
作者
Zhang, Long-Jiang [1 ]
Wang, Zhen Jane [2 ]
Lu, Li [1 ]
Zhu, Ke [1 ]
Chai, Xue [1 ]
Zhao, Yan E. [1 ]
Peng, Jin [1 ]
Lu, Guang-Ming [1 ]
机构
[1] Nanjing Univ, Dept Med Imaging, Coll Med, Sch Clin,Jinling Hosp, Nanjing 210002, Jiangsu, Peoples R China
[2] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
Dual energy CT; Airway obstruction; Ventilation imaging; Aerosolised iodinated contrast media; REGIONAL VENTILATION; COMPUTED-TOMOGRAPHY; PULMONARY PERFUSION; XENON; ANGIOGRAPHY; STENOSIS; ANEURYSM; REPAIR;
D O I
10.1016/j.ejrad.2010.10.029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of dual energy CT (DECT) after aerosol inhalation of iodinated contrast medium for the evaluation of ventilation function in rabbits with airway obstruction. Materials and methods: The study was approved by our institutional animal experimental committee and performed according to animal care guidelines. Airway obstruction was created by injecting gelatin sponge into the right bronchus of 6 New Zealand rabbits. One additional rabbit served as control without airway obstruction. All 7 rabbits then underwent inhalation of aerosol iodinated contrast medium for 5 min, followed by DECT of the lungs from which ventilation CT images were created. CT number and overlay value (calculated iodine enhancement on the ventilation images in hounsfield unit) of the obstructed and non-obstructed lung lobes were measured at 80-kVp, 140-kVp, and weighted average 120-kVp. Immediately after DECT scan, the rabbits were sacrificed, the lungs were removed and detailed pathological examination of the locations and parenchymal changes of the obstructed lung lobes were performed and correlated with DECT ventilation imaging findings. Results: Data from one rabbit with airway obstruction were excluded because of post-procedure pneumatothorax. Seventeen normal lung lobes without airway obstruction proven by histopathology had nearly homogeneous ventilation, while 13 abnormal lung lobes had ventilation defects on DECT ventilation images. CT numbers and overlay values of the normal (CT number, -737.77 +/- 71.46 HU, -768.84 +/- 73.86 HU, -731.86 +/- 65.92HU for 140-kVp, 80-kVp, and weighted average 120-kVp; overlay value, 46.58 +/- 19.49 HU) and abnormal lung lobes (CT number, -183.58 +/- 173.37 HU, -124.93 +/- 242.23 HU,-166.07 +/- 191.57HUfor 140-kVp, 80-kVp, and weighted average 120-kVp; overlay value, 0.00 +/- 0.00 HU) were significantly different at 80-kVp, 140-kVp, and weighted average 120-kVp (P < 0.001 for all). Diffuse hemorrhage, inflammatory cell infiltration, and exudation were observed at histopathology in the obstructed lung lobes. Conclusions: It is feasible to study regional lung ventilation function using DECT after aerosol inhalation of iodinated contrast medium in rabbit. The safety of inhalation of iodine contrast medium is unknown, and has to be investigated further before use of this new method in humans. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:266 / 271
页数:6
相关论文
共 50 条
  • [31] Extravasation of Iodinated Contrast Medium During CT: Self-Assessment Module
    Chew, Felix S.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : S80 - S85
  • [32] Differentiation of Hemorrhage from Iodinated Contrast in Different Intracranial Compartments Using Dual-Energy Head CT
    Phan, C. M.
    Yoo, A. J.
    Hirsch, J. A.
    Nogueira, R. G.
    Gupta, R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1088 - 1094
  • [33] Quantitative comparison of dual-energy CT and differential phase contrast CT imaging methods
    Zhang, Xin
    Su, Ting
    Xia, Dongmei
    Liang, Dong
    Ge, Yongshuai
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [34] Aortic dual-energy CT angiography with low contrast medium injection rate
    Liu, Jie
    Lv, Pei-Jie
    Wu, Runze
    Zhang, Yong-Gao
    Hu, Li-Li
    Hou, Ping
    Gao, Jian-Bo
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (05) : 689 - 696
  • [35] Impact of iodinated contrast media concentration on image quality for dual-energy CT and single-energy CT with low tube voltage settings
    Sookpeng, Supawitoo
    Martin, Colin J.
    ACTA RADIOLOGICA, 2023, 64 (03) : 1047 - 1055
  • [36] Dual-energy CT lung ventilation/perfusion imaging for diagnosing pulmonary embolism
    Long Jiang Zhang
    Chang Sheng Zhou
    U. Joseph Schoepf
    Hui Xue Sheng
    Sheng Yong Wu
    Aleksander W. Krazinski
    Justin R. Silverman
    Felix G. Meinel
    Yan E. Zhao
    Zong Jun Zhang
    Guang Ming Lu
    European Radiology, 2013, 23 : 2666 - 2675
  • [37] Dual-energy CT lung ventilation/perfusion imaging for diagnosing pulmonary embolism
    Zhang, Long Jiang
    Zhou, Chang Sheng
    Schoepf, U. Joseph
    Sheng, Hui Xue
    Wu, Sheng Yong
    Krazinski, Aleksander W.
    Silverman, Justin R.
    Meinel, Felix G.
    Zhao, Yan E.
    Zhang, Zong Jun
    Lu, Guang Ming
    EUROPEAN RADIOLOGY, 2013, 23 (10) : 2666 - 2675
  • [38] Positron emission tomography attenuation correction with dual energy CT electron density maps in the presence of iodinated contrast media
    Liu, Leening P.
    Shapira, Nadav
    Scheuermann, Joshua
    Perkins, Amy E.
    Kim, Johoon
    Karp, Joel S.
    Noel, Peter B.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [39] Ultrastructure of epithelium of terminal bronchioles in rabbits after inhalation of mineral water aerosol
    Uhlík, J
    Konrádová, V
    Vajner, L
    Adásková, J
    ACTA VETERINARIA BRNO, 2002, 71 (03) : 283 - +
  • [40] Survey of CT radiation doses and iodinated contrast medium administration: an international multicentric study
    Karout, Lina
    Kalra, Mannudeep K.
    EUROPEAN RADIOLOGY, 2025, 35 (04) : 1915 - 1932