摘要
ObjectiveTo assess the relationship between intravenous iodinated contrast media (ICM) administration usage and radiation doses for contrast-enhanced (CE) CT of head, chest, and abdomen-pelvis (AP) in international, multicenter settings. MethodsOur international (n = 16 countries), multicenter (n = 43 sites), and cross-sectional (ConRad) study had two parts. Part 1: Redcap survey with questions on information related to CT and ICM manufacturer/brand and respective protocols. Part 2: Information on 3,258 patients (18-96 years; M:F 1654:1604) who underwent CECT for a routine head (n = 456), chest (n = 528), AP (n = 599), head CT angiography (n = 539), pulmonary embolism (n = 599), and liver CT examinations (n = 537) at 43 sites across five continents. The following information was recorded: hospital name, patient age, gender, body mass index [BMI], clinical indications, scan parameters (number of scan phases, kV), IV-contrast information (concentration, volume, flow rate, and delay), and dose indices (CTDIvol and DLP). ResultsMost routine chest (58.4%) and AP (68.7%) CECT exams were performed with 2-4 scan phases with fixed scan delay (chest 71.4%; AP 79.8%, liver CECT 50.7%) following ICM administration. Most sites did not change kV across different patients and scan phases; most CECT protocols were performed at 120-140 kV (83%, 1979/2685). There were no significant differences between radiation doses for non-contrast (CTDIvol 24 [16-30] mGy; DLP 633 [414-702] mGy<middle dot>cm) and post-contrast phases (22 [19-27] mGy; 648 [392-694] mGy<middle dot>cm) (p = 0.142). Sites that used bolus tracking for chest and AP CECT had lower CTDIvol than sites with fixed scan delays (p < 0.001). There was no correlation between BMI and CTDIvol (r2 <= - 0.1 to 0.1, p = 0.931). ConclusionOur study demonstrates up to ten-fold variability in ICM injection protocols and radiation doses across different CT protocols. The study emphasizes the need for optimizing CT scanning and contrast protocols to reduce unnecessary contrast and radiation exposure to patients. Clinical relevance statementThe wide variability and lack of standardization of ICM media and radiation doses in CT protocols suggest the need for education and optimization of contrast usage and scan factors for optimizing image quality in CECT. Key Points...
引用
收藏
页码:1915 / 1932
页数:18
相关论文
共 50 条
  • [1] Reduction of iodinated contrast medium in CT: feasibility study
    Nasirudin, Radin A.
    Mei, Kai
    Kopp, Felix K.
    Penchev, Petar
    Rummeny, Ernst J.
    Fiebich, Martin
    Noel, Peter B.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [2] Determination of serum creatinine level before intravenous administration of iodinated contrast medium - A survey
    Lee, JKT
    Warshauer, DM
    Bush, WH
    McClennan, BL
    Choyke, PL
    INVESTIGATIVE RADIOLOGY, 1995, 30 (12) : 700 - 705
  • [3] A Survey of Practicing Radiologists on the Use of Premedication Before Intravenous Iodinated Contrast Medium Administration
    Sodagari, Faezeh
    Davenport, Mathew S.
    Asch, Daniella
    Cavallo, Joseph J.
    Cohan, Richard H.
    Ellis, James H.
    Pahade, Jay K.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2024, 21 (05) : 795 - 804
  • [4] A Survey of Practicing Radiologists on the Use of Premedication Before Intravenous Iodinated Contrast Medium Administration Reply
    Pahade, Jay K.
    Sodagari, Faezeh
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2024, 21 (06) : 849 - 850
  • [5] A method to evaluate the dose increase in CT with iodinated contrast medium
    Amato, Ernesto
    Lizio, Domenico
    Settineri, Nicola
    Di Pasquale, Andrea
    Salamone, Ignazio
    Pandolfo, Ignazio
    MEDICAL PHYSICS, 2010, 37 (08) : 4249 - 4256
  • [6] ENHANCED RADIATION RESPONSE IN THE PRESENCE OF IODINATED CONTRAST-MEDIUM
    PENHALIGON, M
    DAWSON, P
    SMITH, E
    SAUNDERS, J
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1987, 52 (03) : 483 - 484
  • [7] REACTION TO INTRAARTERIAL IONIC IODINATED CONTRAST MEDIUM ADMINISTRATION IN ANESTHETIZED HORSES
    Pollard, Rachel E.
    Puchalski, Sarah M.
    VETERINARY RADIOLOGY & ULTRASOUND, 2011, 52 (04) : 441 - 443
  • [8] Safety of Iodinated Intravenous Contrast Medium Administration in Sickle Cell Disease
    Campbell, Kimberly L.
    Hud, Laryssa M.
    Adams, Suzanne
    Andrel, Jocelyn
    Ballas, Samir K.
    Feldman, Arthur M.
    Axelrod, David
    AMERICAN JOURNAL OF MEDICINE, 2012, 125 (01):
  • [9] Contrast medium protocols in routine chest CT: a survey study
    Henning, Mette Karen
    Aalokken, Trond Mogens
    Johansen, Safora
    ACTA RADIOLOGICA, 2022, 63 (03) : 351 - 359
  • [10] Use of Contrast Medium for CT in Abdominal Trauma: An International Survey of Hospital Practice
    Wat, S. J.
    Groves, A. M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)