Survey of CT radiation doses and iodinated contrast medium administration: an international multicentric study

被引:3
|
作者
Karout, Lina [1 ]
Kalra, Mannudeep K. [2 ]
机构
[1] Massachusetts Gen Hosp, Boston, MA USA
[2] Jordan Univ Sci & Technol, Fac Appl Med, Irbid, Jordan
关键词
Radiation; X-ray computed tomography; Adult; Contrast;
D O I
10.1007/s00330-024-11017-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveTo assess the relationship between intravenous iodinated contrast media (ICM) administration usage and radiation doses for contrast-enhanced (CE) CT of head, chest, and abdomen-pelvis (AP) in international, multicenter settings. MethodsOur international (n = 16 countries), multicenter (n = 43 sites), and cross-sectional (ConRad) study had two parts. Part 1: Redcap survey with questions on information related to CT and ICM manufacturer/brand and respective protocols. Part 2: Information on 3,258 patients (18-96 years; M:F 1654:1604) who underwent CECT for a routine head (n = 456), chest (n = 528), AP (n = 599), head CT angiography (n = 539), pulmonary embolism (n = 599), and liver CT examinations (n = 537) at 43 sites across five continents. The following information was recorded: hospital name, patient age, gender, body mass index [BMI], clinical indications, scan parameters (number of scan phases, kV), IV-contrast information (concentration, volume, flow rate, and delay), and dose indices (CTDIvol and DLP). ResultsMost routine chest (58.4%) and AP (68.7%) CECT exams were performed with 2-4 scan phases with fixed scan delay (chest 71.4%; AP 79.8%, liver CECT 50.7%) following ICM administration. Most sites did not change kV across different patients and scan phases; most CECT protocols were performed at 120-140 kV (83%, 1979/2685). There were no significant differences between radiation doses for non-contrast (CTDIvol 24 [16-30] mGy; DLP 633 [414-702] mGy<middle dot>cm) and post-contrast phases (22 [19-27] mGy; 648 [392-694] mGy<middle dot>cm) (p = 0.142). Sites that used bolus tracking for chest and AP CECT had lower CTDIvol than sites with fixed scan delays (p < 0.001). There was no correlation between BMI and CTDIvol (r2 <= - 0.1 to 0.1, p = 0.931). ConclusionOur study demonstrates up to ten-fold variability in ICM injection protocols and radiation doses across different CT protocols. The study emphasizes the need for optimizing CT scanning and contrast protocols to reduce unnecessary contrast and radiation exposure to patients. Clinical relevance statementThe wide variability and lack of standardization of ICM media and radiation doses in CT protocols suggest the need for education and optimization of contrast usage and scan factors for optimizing image quality in CECT. Key Points...
引用
收藏
页码:1915 / 1932
页数:18
相关论文
共 50 条
  • [31] Administration of nonionic iodinated contrast medium does not influence the outcome of patients with ischemic brain infarction
    Palomäki, H
    Muuronen, A
    Raininko, R
    Piilonen, A
    Kaste, M
    CEREBROVASCULAR DISEASES, 2003, 15 (1-2) : 45 - 50
  • [32] Risk of developing acute kidney injury (AKI) following the administration of iodinated contrast medium Response
    Prescott, Alison M.
    Lewington, Andrew J. P.
    O'Donoghue, Donal
    CLINICAL MEDICINE, 2012, 12 (06) : 608 - 608
  • [33] Modifications of Renal Function in Cancer Patients Undergoing Repeated and Frequent Administrations of Iodinated Contrast Medium (CM): A Multicentric Retrospective Study from Italy
    Cosmai, Laura
    Pirovano, Marta
    Sarto, Giulia V. Re
    Porta, Camillo
    Gallieni, Maurizio
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2021, 32 (10): : 581 - 581
  • [34] Highly iodinated intravenous contrast material for PET/CT - a feasibility study
    不详
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2008, 180 (08): : 740 - 745
  • [35] IV contrast administration for CT: A survey of practices for the screening and prevention of contrast nephropathy
    Elicker, BM
    Cypel, YS
    Weinreb, JC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) : 1651 - 1658
  • [36] Dual energy CT ventilation imaging after aerosol inhalation of iodinated contrast medium in rabbits
    Zhang, Long-Jiang
    Wang, Zhen Jane
    Lu, Li
    Zhu, Ke
    Chai, Xue
    Zhao, Yan E.
    Peng, Jin
    Lu, Guang-Ming
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 78 (02) : 266 - 271
  • [37] Influence of the X-ray beam quality on the dose increment in CT with iodinated contrast medium
    Amato, Ernesto
    Asero, Grazia
    Leotta, Salvatore
    Auditore, Lucrezia
    Salamone, Ignazio
    Mannino, Giovanni
    Privitera, Salvatore
    Gueli, Anna
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (02) : 267 - 278
  • [38] CT findings of isolated small bowel angioedema due to iodinated radiographic contrast medium reaction
    Kim, SH
    Cho, JY
    Lim, HK
    ABDOMINAL IMAGING, 1999, 24 (02): : 117 - 119
  • [39] A method of regional cerebral blood perfusion measurement using dynamic CT with an iodinated contrast medium
    Nambu, K
    Takehara, R
    Terada, T
    ACTA NEUROLOGICA SCANDINAVICA, 1996, 93 : 28 - 31
  • [40] THE USE OF HIGH CONTRAST DOSES IN CT FIBROMATOSIS STUDY
    TAVIERE, V
    COUANET, D
    PEDIATRIC RADIOLOGY, 1986, 16 (04) : 344 - 344