Dual energy CT ventilation imaging after aerosol inhalation of iodinated contrast medium in rabbits

被引:6
|
作者
Zhang, Long-Jiang [1 ]
Wang, Zhen Jane [2 ]
Lu, Li [1 ]
Zhu, Ke [1 ]
Chai, Xue [1 ]
Zhao, Yan E. [1 ]
Peng, Jin [1 ]
Lu, Guang-Ming [1 ]
机构
[1] Nanjing Univ, Dept Med Imaging, Coll Med, Sch Clin,Jinling Hosp, Nanjing 210002, Jiangsu, Peoples R China
[2] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
Dual energy CT; Airway obstruction; Ventilation imaging; Aerosolised iodinated contrast media; REGIONAL VENTILATION; COMPUTED-TOMOGRAPHY; PULMONARY PERFUSION; XENON; ANGIOGRAPHY; STENOSIS; ANEURYSM; REPAIR;
D O I
10.1016/j.ejrad.2010.10.029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of dual energy CT (DECT) after aerosol inhalation of iodinated contrast medium for the evaluation of ventilation function in rabbits with airway obstruction. Materials and methods: The study was approved by our institutional animal experimental committee and performed according to animal care guidelines. Airway obstruction was created by injecting gelatin sponge into the right bronchus of 6 New Zealand rabbits. One additional rabbit served as control without airway obstruction. All 7 rabbits then underwent inhalation of aerosol iodinated contrast medium for 5 min, followed by DECT of the lungs from which ventilation CT images were created. CT number and overlay value (calculated iodine enhancement on the ventilation images in hounsfield unit) of the obstructed and non-obstructed lung lobes were measured at 80-kVp, 140-kVp, and weighted average 120-kVp. Immediately after DECT scan, the rabbits were sacrificed, the lungs were removed and detailed pathological examination of the locations and parenchymal changes of the obstructed lung lobes were performed and correlated with DECT ventilation imaging findings. Results: Data from one rabbit with airway obstruction were excluded because of post-procedure pneumatothorax. Seventeen normal lung lobes without airway obstruction proven by histopathology had nearly homogeneous ventilation, while 13 abnormal lung lobes had ventilation defects on DECT ventilation images. CT numbers and overlay values of the normal (CT number, -737.77 +/- 71.46 HU, -768.84 +/- 73.86 HU, -731.86 +/- 65.92HU for 140-kVp, 80-kVp, and weighted average 120-kVp; overlay value, 46.58 +/- 19.49 HU) and abnormal lung lobes (CT number, -183.58 +/- 173.37 HU, -124.93 +/- 242.23 HU,-166.07 +/- 191.57HUfor 140-kVp, 80-kVp, and weighted average 120-kVp; overlay value, 0.00 +/- 0.00 HU) were significantly different at 80-kVp, 140-kVp, and weighted average 120-kVp (P < 0.001 for all). Diffuse hemorrhage, inflammatory cell infiltration, and exudation were observed at histopathology in the obstructed lung lobes. Conclusions: It is feasible to study regional lung ventilation function using DECT after aerosol inhalation of iodinated contrast medium in rabbit. The safety of inhalation of iodine contrast medium is unknown, and has to be investigated further before use of this new method in humans. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:266 / 271
页数:6
相关论文
共 50 条
  • [1] Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study
    Jia Wang
    Mingliang Qu
    Xinhui Duan
    Naoki Takahashi
    Akira Kawashima
    Shuai Leng
    Cynthia H. McCollough
    European Radiology, 2012, 22 : 2589 - 2596
  • [2] Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study
    Wang, Jia
    Qu, Mingliang
    Duan, Xinhui
    Takahashi, Naoki
    Kawashima, Akira
    Leng, Shuai
    McCollough, Cynthia H.
    EUROPEAN RADIOLOGY, 2012, 22 (12) : 2589 - 2596
  • [3] Generation of ventilation/perfusion ratio map in surgical patients by dual-energy CT after xenon inhalation and intravenous contrast media
    Kohei Aoki
    Yotaro Izumi
    Wataru Watanabe
    Yuji Shimizu
    Hisato Osada
    Norinari Honda
    Toshihide Itoh
    Mitsuo Nakayama
    Journal of Cardiothoracic Surgery, 13
  • [4] Generation of ventilation/perfusion ratio map in surgical patients by dual-energy CT after xenon inhalation and intravenous contrast media
    Aoki, Kohei
    Izumi, Yotaro
    Watanabe, Wataru
    Shimizu, Yuji
    Osada, Hisato
    Honda, Norinari
    Itoh, Toshihide
    Nakayama, Mitsuo
    JOURNAL OF CARDIOTHORACIC SURGERY, 2018, 13
  • [5] The use of CT dual-energy subtraction imaging to detect kidney stones amid iodinated contrast material
    Dzyubak, O. P.
    Primak, A. N.
    Takahashi, N.
    Vrtiska, T. J.
    Hartman, R. P.
    Kawashima, A.
    Fletcher, J. G.
    Yu, L.
    McCollough, C. H.
    MEDICAL PHYSICS, 2007, 34 (06) : 2555 - 2555
  • [6] Novel Lung Ventilation Imaging with Single Energy CT After Single Inhalation of Xenon: Comparison with SPECT Ventilation Images
    Negahdar, M.
    Yamamoto, T.
    Shultz, D.
    Gable, L.
    Shan, X.
    Mittra, E.
    Diehn, M.
    Loo, B.
    Maxim, P.
    MEDICAL PHYSICS, 2014, 41 (06) : 450 - 450
  • [7] HYPERTHYROIDISM AFTER IODINATED CONTRAST-MEDIUM
    BLUM, M
    WEINBERG, U
    SHENKMAN, L
    HOLLANDER, CS
    NEW ENGLAND JOURNAL OF MEDICINE, 1974, 291 (01): : 24 - 25
  • [8] Reduction of iodinated contrast medium in CT: feasibility study
    Nasirudin, Radin A.
    Mei, Kai
    Kopp, Felix K.
    Penchev, Petar
    Rummeny, Ernst J.
    Fiebich, Martin
    Noel, Peter B.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [9] Multi-energy CT and iodinated contrast
    Villanueva Campos, A.
    Canales Lachen, E.
    Suevos Ballesteros, C.
    Alarcon Rodriguez, J.
    RADIOLOGIA, 2024, 66 : S29 - S35
  • [10] Dual-energy CT enables dose calculation on scans with iodinated contrast agent
    Moehler, C.
    Wohlfahrt, P.
    Nicolay, N. H.
    Richter, C.
    Greilich, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1147 - S1148