Dual energy CT ventilation imaging after aerosol inhalation of iodinated contrast medium in rabbits

被引:6
|
作者
Zhang, Long-Jiang [1 ]
Wang, Zhen Jane [2 ]
Lu, Li [1 ]
Zhu, Ke [1 ]
Chai, Xue [1 ]
Zhao, Yan E. [1 ]
Peng, Jin [1 ]
Lu, Guang-Ming [1 ]
机构
[1] Nanjing Univ, Dept Med Imaging, Coll Med, Sch Clin,Jinling Hosp, Nanjing 210002, Jiangsu, Peoples R China
[2] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
Dual energy CT; Airway obstruction; Ventilation imaging; Aerosolised iodinated contrast media; REGIONAL VENTILATION; COMPUTED-TOMOGRAPHY; PULMONARY PERFUSION; XENON; ANGIOGRAPHY; STENOSIS; ANEURYSM; REPAIR;
D O I
10.1016/j.ejrad.2010.10.029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of dual energy CT (DECT) after aerosol inhalation of iodinated contrast medium for the evaluation of ventilation function in rabbits with airway obstruction. Materials and methods: The study was approved by our institutional animal experimental committee and performed according to animal care guidelines. Airway obstruction was created by injecting gelatin sponge into the right bronchus of 6 New Zealand rabbits. One additional rabbit served as control without airway obstruction. All 7 rabbits then underwent inhalation of aerosol iodinated contrast medium for 5 min, followed by DECT of the lungs from which ventilation CT images were created. CT number and overlay value (calculated iodine enhancement on the ventilation images in hounsfield unit) of the obstructed and non-obstructed lung lobes were measured at 80-kVp, 140-kVp, and weighted average 120-kVp. Immediately after DECT scan, the rabbits were sacrificed, the lungs were removed and detailed pathological examination of the locations and parenchymal changes of the obstructed lung lobes were performed and correlated with DECT ventilation imaging findings. Results: Data from one rabbit with airway obstruction were excluded because of post-procedure pneumatothorax. Seventeen normal lung lobes without airway obstruction proven by histopathology had nearly homogeneous ventilation, while 13 abnormal lung lobes had ventilation defects on DECT ventilation images. CT numbers and overlay values of the normal (CT number, -737.77 +/- 71.46 HU, -768.84 +/- 73.86 HU, -731.86 +/- 65.92HU for 140-kVp, 80-kVp, and weighted average 120-kVp; overlay value, 46.58 +/- 19.49 HU) and abnormal lung lobes (CT number, -183.58 +/- 173.37 HU, -124.93 +/- 242.23 HU,-166.07 +/- 191.57HUfor 140-kVp, 80-kVp, and weighted average 120-kVp; overlay value, 0.00 +/- 0.00 HU) were significantly different at 80-kVp, 140-kVp, and weighted average 120-kVp (P < 0.001 for all). Diffuse hemorrhage, inflammatory cell infiltration, and exudation were observed at histopathology in the obstructed lung lobes. Conclusions: It is feasible to study regional lung ventilation function using DECT after aerosol inhalation of iodinated contrast medium in rabbit. The safety of inhalation of iodine contrast medium is unknown, and has to be investigated further before use of this new method in humans. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:266 / 271
页数:6
相关论文
共 50 条
  • [21] Optimization of thoracic spiral CT: Effects of iodinated contrast medium concentration
    Rubin, GD
    Lane, MJ
    Bloch, DA
    Leung, AN
    Stark, P
    RADIOLOGY, 1996, 201 (03) : 785 - 791
  • [22] BODY CT WITH HIGH-DOSE IODINATED CONTRAST-MEDIUM
    PATEL, S
    RAUSCHKOLB, E
    STRAX, R
    TOOMBS, B
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (06) : 942 - 942
  • [23] T4-THYROID STORM AFTER CT-SCAN WITH IODINATED CONTRAST-MEDIUM
    SHIMURA, H
    TAKAZAWA, K
    ENDO, T
    TAWATA, M
    ONAYA, T
    JOURNAL OF ENDOCRINOLOGICAL INVESTIGATION, 1990, 13 (01) : 73 - 76
  • [24] Evaluation of Dual-Energy CT for Differentiating Intracerebral Hemorrhage from Iodinated Contrast Material Staining
    Gupta, Rajiv
    Phan, Catherine M.
    Leidecker, Christianne
    Brady, Thomas J.
    Hirsch, Joshua A.
    Nogueira, Raul G.
    Yoo, Albert J.
    RADIOLOGY, 2010, 257 (01) : 205 - 211
  • [25] The potential of iodinated contrast reduction in dual-energy CT thoracic angiography; an evaluation of image quality
    Johansen, C. B.
    Martinsen, A. C. T.
    Enden, T. R.
    Svanteson, M.
    RADIOGRAPHY, 2022, 28 (01) : 2 - 7
  • [26] Quantitative Imaging of a Gold Nanoparticle Contrast Agent with Dual Energy CT
    Ducote, J. L.
    Le, H. Q.
    Alivov, Y.
    Molloi, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [27] Xenon-Enhanced Dual-Energy CT of Patients With Asthma: Dynamic Ventilation Changes After Methacholine and Salbutamol Inhalation
    Kim, Won Wha
    Lee, Chang Hyun
    Goo, Jin Mo
    Park, Sang Joon
    Kim, Jong Hyo
    Park, Eun-Ah
    Cho, Sang-Heon
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : 975 - 981
  • [28] Dual Energy Differential Phase Contrast CT (DE-DPC-CT) Imaging
    Ji, Xu
    Zhang, Ran
    Li, Ke
    Chen, Guang-Hong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (11) : 3278 - 3289
  • [29] Safety of intravenous iodinated contrast medium injection in rabbits undergoing conscious computed tomography
    Isaac, Ingrid
    Richardson, Jenna
    Liuti, Tiziana
    Longo, Maurizio
    VETERINARY RECORD OPEN, 2022, 9 (01)
  • [30] Potential of dual-layer spectral CT for the differentiation between hemorrhage and iodinated contrast medium in the brain after endovascular treatment of ischemic stroke patients
    Riederer, Isabelle
    Fingerle, Alexander A.
    Zimmer, Claus
    Noel, Peter B.
    Makowski, Marcus R.
    Pfeiffer, Daniela
    CLINICAL IMAGING, 2021, 79 : 158 - 164