Dual energy CT ventilation imaging after aerosol inhalation of iodinated contrast medium in rabbits

被引:6
|
作者
Zhang, Long-Jiang [1 ]
Wang, Zhen Jane [2 ]
Lu, Li [1 ]
Zhu, Ke [1 ]
Chai, Xue [1 ]
Zhao, Yan E. [1 ]
Peng, Jin [1 ]
Lu, Guang-Ming [1 ]
机构
[1] Nanjing Univ, Dept Med Imaging, Coll Med, Sch Clin,Jinling Hosp, Nanjing 210002, Jiangsu, Peoples R China
[2] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
Dual energy CT; Airway obstruction; Ventilation imaging; Aerosolised iodinated contrast media; REGIONAL VENTILATION; COMPUTED-TOMOGRAPHY; PULMONARY PERFUSION; XENON; ANGIOGRAPHY; STENOSIS; ANEURYSM; REPAIR;
D O I
10.1016/j.ejrad.2010.10.029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of dual energy CT (DECT) after aerosol inhalation of iodinated contrast medium for the evaluation of ventilation function in rabbits with airway obstruction. Materials and methods: The study was approved by our institutional animal experimental committee and performed according to animal care guidelines. Airway obstruction was created by injecting gelatin sponge into the right bronchus of 6 New Zealand rabbits. One additional rabbit served as control without airway obstruction. All 7 rabbits then underwent inhalation of aerosol iodinated contrast medium for 5 min, followed by DECT of the lungs from which ventilation CT images were created. CT number and overlay value (calculated iodine enhancement on the ventilation images in hounsfield unit) of the obstructed and non-obstructed lung lobes were measured at 80-kVp, 140-kVp, and weighted average 120-kVp. Immediately after DECT scan, the rabbits were sacrificed, the lungs were removed and detailed pathological examination of the locations and parenchymal changes of the obstructed lung lobes were performed and correlated with DECT ventilation imaging findings. Results: Data from one rabbit with airway obstruction were excluded because of post-procedure pneumatothorax. Seventeen normal lung lobes without airway obstruction proven by histopathology had nearly homogeneous ventilation, while 13 abnormal lung lobes had ventilation defects on DECT ventilation images. CT numbers and overlay values of the normal (CT number, -737.77 +/- 71.46 HU, -768.84 +/- 73.86 HU, -731.86 +/- 65.92HU for 140-kVp, 80-kVp, and weighted average 120-kVp; overlay value, 46.58 +/- 19.49 HU) and abnormal lung lobes (CT number, -183.58 +/- 173.37 HU, -124.93 +/- 242.23 HU,-166.07 +/- 191.57HUfor 140-kVp, 80-kVp, and weighted average 120-kVp; overlay value, 0.00 +/- 0.00 HU) were significantly different at 80-kVp, 140-kVp, and weighted average 120-kVp (P < 0.001 for all). Diffuse hemorrhage, inflammatory cell infiltration, and exudation were observed at histopathology in the obstructed lung lobes. Conclusions: It is feasible to study regional lung ventilation function using DECT after aerosol inhalation of iodinated contrast medium in rabbit. The safety of inhalation of iodine contrast medium is unknown, and has to be investigated further before use of this new method in humans. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:266 / 271
页数:6
相关论文
共 50 条
  • [41] Performance evaluation of dual-energy CT and differential phase contrast CT in quantitative imaging applications
    Zhang, Xin
    Su, Ting
    Yang, Jiecheng
    Zhu, Jiongtao
    Xia, Dongmei
    Zheng, Hairong
    Liang, Dong
    Ge, Yongshuai
    MEDICAL PHYSICS, 2022, 49 (02) : 1123 - 1138
  • [42] The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke
    Tijssen, M. P. M.
    Hofman, P. A. M.
    Stadler, A. A. R.
    van Zwam, W.
    de Graaf, R.
    van Oostenbrugge, R. J.
    Klotz, E.
    Wildberger, J. E.
    Postma, A. A.
    EUROPEAN RADIOLOGY, 2014, 24 (04) : 834 - 840
  • [43] The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke
    M. P. M. Tijssen
    P. A. M. Hofman
    A. A. R. Stadler
    W. van Zwam
    R. de Graaf
    R. J. van Oostenbrugge
    E. Klotz
    J. E. Wildberger
    A. A. Postma
    European Radiology, 2014, 24 : 834 - 840
  • [44] INTESTINAL CONTRAST IMAGING IN ABDOMINAL CT - WATER OR CONTRAST-MEDIUM
    SCHUNK, K
    DUBER, C
    KREITNER, KF
    BRUNIER, A
    KLOSE, KJ
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (04): : 407 - 413
  • [45] INTESTINAL CONTRAST IMAGING IN ABDOMINAL CT - WATER OR CONTRAST-MEDIUM
    TROGER, J
    BUSSMANN, H
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 155 (04): : 382 - 382
  • [46] Dual Energy imaging in cardiovascular CT: Current status and impact on radiation, contrast and accuracy
    Rajiah P.
    Halliburton S.S.
    Current Cardiovascular Imaging Reports, 2014, 7 (10) : 1 - 11
  • [47] DISCRIMINATION BETWEEN THOROTRAST AND IODINE CONTRAST-MEDIUM BY MEANS OF DUAL ENERGY CT SCANNING
    TAKAI, M
    KANEKO, M
    MEDICAL PHYSICS, 1983, 10 (01) : 130 - 130
  • [48] Dual-Energy CT Ventilation & Perfusion Imaging as An Accessible Alternative to Nuclear Medicine Techniques
    Korte, J.
    Bucknell, N.
    Siva, S.
    Woon, B.
    Jackson, P.
    Mulcahy, T.
    Callahan, J.
    Kron, T.
    Hardcastle, N.
    MEDICAL PHYSICS, 2019, 46 (06) : E408 - E408
  • [49] Influence of the X-ray beam quality on the dose increment in CT with iodinated contrast medium
    Amato, Ernesto
    Asero, Grazia
    Leotta, Salvatore
    Auditore, Lucrezia
    Salamone, Ignazio
    Mannino, Giovanni
    Privitera, Salvatore
    Gueli, Anna
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (02) : 267 - 278
  • [50] Functional imaging of tumors using CT and iodinated contrast media of different molecular weights
    Clément, O
    Robert, P
    Cuénod, CA
    Siauve, N
    Sobotka, A
    Kahn, E
    Frija, G
    ACADEMIC RADIOLOGY, 2002, 9 : S212 - S214