A comparison of transthoracic impedance using standard defibrillation paddles and self-adhesive defibrillation pads

被引:20
|
作者
Deakin, CD [1 ]
McLaren, RM [1 ]
Petley, GW [1 ]
Clewlow, F [1 ]
Dalrymple-Hay, MJR [1 ]
机构
[1] Southampton Univ Hosp, NHS Trust, Southampton Gen Hosp, Dept Anaesthesia, Southampton SO16 6YD, Hants, England
关键词
defibrillation; transthoracic impedance; defibrillation paddles;
D O I
10.1016/S0300-9572(98)00117-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The success of defibrillation is related to transmyocardial current. This current is inversely proportional to transthoracic impedance (TTI). A similar TTI between different pads and paddles is important to deliver a consistent therapeutic dose to all subjects. Failure to do so may result in either insufficient or excessive transmyocardial current leading to a risk of failed defibrillation or tissue damage respectively. Several different types of defibrillation paddles and self-adhesive defibrillation pads are currently available for clinical use but the TTI achieved with each type has not been established. We measured TTI using two types of commonly used paddles and self-adhesive pads to establish whether any significant differences exist between the products. TTI in 40 adult males was measured using defibrillation paddles and self-adhesive defibrillation pads placed in the antero-apical position. Measurements were made using a 30 kHz low amplitude AC current and taken at end-expiration. Mean TTI (Omega) +/- S.D. was 68.2 +/- 16.1 (Hewlett Packard paddles; A), 62.8 +/- 13.2 (Hewlett Packard pads; B), 64.6 +/- 14.3 (PhysioControl paddles, C) and 95.6 +/- 22.3 (PhysioControl pads; D). Significant differences existed between all groups (P < 0.05) except between B and C. Differences in TTI between A, B and C were small and probably of no clinical significance. TTI in group D is significantly larger. Although transmyocardial current is related to TTI, the relationship is complex and differences in TTI alone cannot predict the outcome from defibrillation. (C) 1998 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:43 / 46
页数:4
相关论文
共 50 条
  • [21] DEFIBRILLATION SKILLS OF PEDIATRIC ACUTE CARE PROVIDERS: ARE THEY FASTER WITH PADDLES OR PADS?
    Bhalala, Utpal
    Balakumar, Niveditha
    Zamora, Maria
    Appachi, Elumalai
    CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [22] Possibilities for predictive measurement of the transthoracic impedance in defibrillation
    Krasteva, V
    Al Hatib, F
    Trendafilova, E
    Daskalov, I
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 2001, 25 (05) : 195 - 200
  • [23] TRANSTHORACIC DEFIBRILLATION - EFFECT OF STERNOTOMY ON CHEST IMPEDANCE
    KERBER, RE
    VANCE, S
    SCHOMER, SJ
    MARIANO, DJ
    CHARBONNIER, F
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (01) : 94 - 97
  • [24] Transthoracic defibrillation: Does electrode position alter transthoracic impedance?
    Garcia, LA
    Kerber, RE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 93362 - 93362
  • [25] A comparison of endocardial defibrillation with three transthoracic defibrillation configurations in a porcine model
    Michael, K. A.
    Paisey, J. R.
    Bullens, R. W.
    Smits, K. F.
    Roberts, P. R.
    Morgan, J. M.
    CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 : 207C - 207C
  • [26] Circulation detection using the electrocardiogram and the thoracic impedance acquired by defibrillation pads
    Alonso, Erik
    Aramendi, Elisabete
    Daya, Mohamud
    Irusta, Unai
    Chicote, Beatriz
    Russell, James K.
    Tereshchenko, Larisa G.
    RESUSCITATION, 2016, 99 : 56 - 62
  • [27] CURRENT-BASED TRANSTHORACIC DEFIBRILLATION IS SUPERIOR TO ENERGY-BASED DEFIBRILLATION IN PATIENTS WITH HIGH TRANSTHORACIC IMPEDANCE
    KERBER, RE
    KIENZLE, MG
    OLSHANSKY, B
    CARLSON, MD
    WALDO, AL
    WILBER, D
    ASCHOFF, AM
    BIRGER, S
    WALSH, S
    FOXEASTHAM, K
    ROCKWELL, M
    CHARBONNIER, F
    CLINICAL RESEARCH, 1991, 39 (03): : A690 - A690
  • [28] Transthoracic electrical impedance during external defibrillation: comparison of measured and modelled waveforms
    Al Hatib, F
    Trendafilova, E
    Daskalov, I
    PHYSIOLOGICAL MEASUREMENT, 2000, 21 (01) : 145 - 153
  • [29] Changes in transthoracic impedance during sequential biphasic defibrillation
    Deakin, Charles D.
    Ambler, Jonathan J. S.
    Shaw, Steven
    RESUSCITATION, 2008, 78 (02) : 141 - 145
  • [30] A Systematic Review of the Transthoracic Impedance during Cardiac Defibrillation
    Heyer, Yasmine
    Baumgartner, Daniela
    Baumgartner, Christian
    SENSORS, 2022, 22 (07)