A comparison of transthoracic impedance using standard defibrillation paddles and self-adhesive defibrillation pads

被引:20
|
作者
Deakin, CD [1 ]
McLaren, RM [1 ]
Petley, GW [1 ]
Clewlow, F [1 ]
Dalrymple-Hay, MJR [1 ]
机构
[1] Southampton Univ Hosp, NHS Trust, Southampton Gen Hosp, Dept Anaesthesia, Southampton SO16 6YD, Hants, England
关键词
defibrillation; transthoracic impedance; defibrillation paddles;
D O I
10.1016/S0300-9572(98)00117-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The success of defibrillation is related to transmyocardial current. This current is inversely proportional to transthoracic impedance (TTI). A similar TTI between different pads and paddles is important to deliver a consistent therapeutic dose to all subjects. Failure to do so may result in either insufficient or excessive transmyocardial current leading to a risk of failed defibrillation or tissue damage respectively. Several different types of defibrillation paddles and self-adhesive defibrillation pads are currently available for clinical use but the TTI achieved with each type has not been established. We measured TTI using two types of commonly used paddles and self-adhesive pads to establish whether any significant differences exist between the products. TTI in 40 adult males was measured using defibrillation paddles and self-adhesive defibrillation pads placed in the antero-apical position. Measurements were made using a 30 kHz low amplitude AC current and taken at end-expiration. Mean TTI (Omega) +/- S.D. was 68.2 +/- 16.1 (Hewlett Packard paddles; A), 62.8 +/- 13.2 (Hewlett Packard pads; B), 64.6 +/- 14.3 (PhysioControl paddles, C) and 95.6 +/- 22.3 (PhysioControl pads; D). Significant differences existed between all groups (P < 0.05) except between B and C. Differences in TTI between A, B and C were small and probably of no clinical significance. TTI in group D is significantly larger. Although transmyocardial current is related to TTI, the relationship is complex and differences in TTI alone cannot predict the outcome from defibrillation. (C) 1998 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:43 / 46
页数:4
相关论文
共 50 条
  • [31] DEFIBRILLATION OF THE HEART DURING CARDIOSURGICAL INTERVENTIONS WITH EXTERNAL, FLEXIBLE SELF-ADHESIVE DISPOSABLE ELECTRODES
    ENGEL, C
    ISRINGHAUS, H
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1990, 31 (06): : 170 - 171
  • [32] TRANSCHEST DEFIBRILLATION EFFECTIVENESS AND ELECTRICAL-IMPEDANCE USING DISPOSABLE CONDUCTIVE PADS
    TACKER, WA
    HEART & LUNG, 1983, 12 (05): : 510 - 513
  • [33] EXPERIMENTAL EVALUATION AND INITIAL CLINICAL-APPLICATION OF NEW SELF-ADHESIVE DEFIBRILLATION ELECTRODES
    KERBER, RE
    MARTINS, JB
    FERGUSON, DW
    JENSEN, SR
    PARKE, JD
    KIESO, R
    MELTON, J
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1985, 8 (01) : 57 - 66
  • [34] ELECTRODE-SUBJECT IMPEDANCE DURING TRANSTHORACIC VENTRICULAR DEFIBRILLATION
    GEDDES, LA
    TACKER, WA
    CABLER, PS
    GOTHARD, R
    FEDERATION PROCEEDINGS, 1974, 33 (03) : 332 - 332
  • [35] Manual defibrillation using paddles-Which is the best technique?
    Cebula, Grzegorz
    Krawczyk, Pawel
    Kononowicz, Andrzej A.
    Koszowski, Marcin
    Odrzywolek, Ryszard
    Andres, Janusz
    RESUSCITATION, 2012, 83 (05) : E127 - E128
  • [36] New moisturizing hydrogel electrodes reduce transthoracic impedance and should facilitate transthoracic defibrillation
    Bissing, JW
    Kerber, RE
    CIRCULATION, 1998, 98 (17) : 174 - 174
  • [37] Reliable extraction of the circulation component in the thoracic impedance measured by defibrillation pads
    Ruiz, J.
    Alonso, E.
    Aramendi, E.
    Kramer-Johansen, J.
    Eftestol, T.
    Ayala, U.
    Gonzalez-Otero, D.
    RESUSCITATION, 2013, 84 (10) : 1345 - 1352
  • [38] Comparison of the effects of removal of chest hair with not doing so before external defibrillation on transthoracic impedance
    Sado, DM
    Deakin, CD
    Petley, GW
    Clewlow, F
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (01): : 98 - 100
  • [39] Differential contribution of skin impedance and thoracic volume to transthoracic impedance during external defibrillation
    Deakin, CD
    Sado, DM
    Petley, GW
    Clewlow, F
    RESUSCITATION, 2004, 60 (02) : 171 - 174
  • [40] Effect of Applying Force to Self-Adhesive Electrodes on Transthoracic Impedance: Implications for Electrical Cardioversion
    Ramirez, F. Daniel
    Fiset, Sandra L.
    Cleland, Mark J.
    Zakutney, Timothy J.
    Nery, Pablo B.
    Nair, Girish M.
    Redpath, Calum J.
    Sadek, Mouhannad M.
    Birnie, David H.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2016, 39 (10): : 1141 - 1147