Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma

被引:13
|
作者
Boden, C
Pascual, J
Medeiros, FA
Aihara, M
Weinreb, RN
Sample, PA
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Visual Funct Lab, La Jolla, CA 92093 USA
[3] Univ Tokyo, Dept Ophthalmol, Tokyo 113, Japan
关键词
D O I
10.1167/iovs.04-1108
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare full-threshold (FT) and SITA algorithms for standard automated perimetry (SAP) with frequency-doubling technology perimetry (FDT) in glaucoma, to help clinicians to relate results in patients who have had two or more of these tests during follow-up. METHODS. This study was a retrospective analysis of data from a longitudinal prospective study at the University of California, San Diego. One hundred four eyes of 104 patients with glaucomatous optic neuropathy detected by optic disc stereophotographs were included. All patients had standard perimetry (SITA and FT) and FDT within 3 months of each other. Global indices, abnormality and severity using two threshold algorithms of standard perimetry were compared with FDT. RESULTS. More eyes had normal visual fields by SAP-FT (57 eyes) than by either SAP-SITA (42 eyes) or FDT (45 eyes), although SAP-FT agreed more closely with FDT (kappa = 0.54 +/- 0.08) on the presence of a visual field defect than did SAP-SITA (kappa = 0.34 +/- 0.08). Correlations of FDT to standard perimetry global indices were similar regardless of the threshold strategy used for standard perimetry, yielding r(2) = 0.38-0.57 for SAP-FT with FDT, 0.36-0.54 for SAP-SITA with FDT. CONCLUSIONS. Despite many similarities of SAP-SITA and SAP-FT, switching the standard of comparison from SAP-FT to SAP-SITA changes the relationship to FDT with regard to visual field abnormality, but not correlations of global indices. FDT detected abnormal fields in more eyes than SAP-FT. SAP-FT tended to detect a subset of eyes found abnormal by FDT. Visual field defects may be detected more often by FDT and SAP-SITA in eyes with early visual field loss, but these two tests may not agree on which eyes show field loss in patients who undergo both tests at follow-up.
引用
收藏
页码:2433 / 2439
页数:7
相关论文
共 50 条
  • [31] Impact of diabetes on glaucoma screening using frequency-doubling perimetry
    Realini, T
    Lai, MQ
    Barber, L
    OPHTHALMOLOGY, 2004, 111 (11) : 2133 - 2136
  • [32] Standard achromatic perimetry, short wavelength automated perimetry, and frequency doubling technology for detection of glaucoma damage
    Soliman, MAE
    de Jong, LAMS
    Ismaeil, AA
    van den Berg, TJTP
    de Smet, MD
    OPHTHALMOLOGY, 2002, 109 (03) : 444 - 454
  • [33] A Comparison of Learning Effects for Standard Automated Perimetry, Short-wavelength Automated Perimetry and Frequency-Doubling Technology Perimetry in Healthy Subjects
    Myers, Lorraine
    Hu, Rongrong
    Morgan, Linda S.
    Hoop, Joni S.
    Racette, Lyne
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [34] Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma
    Serguhn, S
    Spiegel, D
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2001, 239 (05) : 351 - 355
  • [35] Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma
    Stefan Serguhn
    Detlev Spiegel
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 351 - 355
  • [36] Effect of myopia on frequency-doubling perimetry
    Ito, A
    Kawabata, H
    Fujimoto, N
    Adachi-Usami, E
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (05) : 1107 - 1110
  • [37] Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, and Humphrey Swedish interactive threshold algorithm-fast perimetry in a glaucoma practice
    Wadood, AC
    Azuara-Blanco, A
    Aspinall, P
    Taguri, A
    King, AJW
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 133 (03) : 327 - 332
  • [38] Frequency-doubling technology and high-pass resolution perimetry in glaucoma and ocular hypertension
    Kalaboukhova, LV
    Lindblom, B
    PERIMETRY UPDATE 2002/2003, 2004, : 147 - 147
  • [39] Frequency doubling perimetry in glaucoma
    Thomas, R
    Bhat, S
    Muliyil, JP
    Parikh, R
    George, R
    JOURNAL OF GLAUCOMA, 2002, 11 (01) : 46 - 50
  • [40] Conventional perimetry and frequency-doubling technique
    Iester, M
    Altieri, M
    Nasciuti, F
    De Feo, F
    Vittone, P
    Traverso, CE
    Calabria, G
    PERIMETRY UPDATE 2002/2003, 2004, : 115 - 119