Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma

被引:9
|
作者
Serguhn, S [1 ]
Spiegel, D [1 ]
机构
[1] Univ Regensburg, Hosp Eye, D-93042 Regensburg, Germany
关键词
D O I
10.1007/s004170100277
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the reproducibility and efficacy of frequency-doubling perimetry (FDP), a new perimetric method for the detection of functional glaucomatous damage. Methods: Thirty-four glaucomatous eyes of 34 patients were examined by FDP (using the complete N30 threshold test of the Humphrey Frequency Perimeter) and by standard achromatic computerized perimetry (SAC; using the full threshold program 30-2 of the Humphrey Field Analyzer). Twenty-six of these eyes were examined twice by FDP. Reproducibility of repeated FDP was tested by the difference and the average of mean deviations (MD). Efficacy was studied by comparison of FDP and SAC using MD, as well as threshold results of FDP and corresponding SAG-tested areas. Spearman's rank correlation was calculated. Results: A significant correlation of repeated FDP examinations was found regarding MD [r=0.94, P <0.00001 (n=26)]. The reproducibility of FDP was independent of the glaucomatous damage [r=0.04, P=0.85 (n=26)], based on the correlation of the difference, and the average of MD. The MD of FDP and that of SAC showed a significant correlation [r-0.87, P <0.00001 (n=34)]. In advanced glaucoma, FDP tended to yield lower measurement values than SAG. Regarding corresponding areas, there was a significant correlation between threshold results of FDP-tested areas and the corresponding SAC testpoints [r=0.92, P <0.00001 (n=34)]. The conformity decreased from the peripheral to the central tested visual field. Conclusions: Sufficient reproducibility of FDP could be demonstrated in early and advanced glaucomatous visual field defects. Conformity between FDP and SAC was shown in terms of MD and threshold results of FDP-tested areas and corresponding SAG testpoints.
引用
收藏
页码:351 / 355
页数:5
相关论文
共 50 条
  • [1] Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma
    Stefan Serguhn
    Detlev Spiegel
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 351 - 355
  • [2] Comparison of frequency doubling perimetry to standard achromatic automated perimetry in glaucoma
    Serguhn, S
    Spiegel, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S842 - S842
  • [3] Frequency-doubling perimetry: Comparison with standard automated perimetry to detect glaucoma
    Leeprechanon, Narakorn
    Giangiacomo, Annette
    Fontana, Hector
    Hoffman, Douglas
    Caprioli, Joseph
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (02) : 263 - 271
  • [4] Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma
    Kampmeier, J
    Eisert, B
    Buchwald, HJ
    Lang, GK
    Lang, GE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (03) : 157 - 167
  • [5] Standard achromatic perimetry, short wavelength automated perimetry, and frequency doubling technology for detection of glaucoma damage
    Soliman, MAE
    de Jong, LAMS
    Ismaeil, AA
    van den Berg, TJTP
    de Smet, MD
    OPHTHALMOLOGY, 2002, 109 (03) : 444 - 454
  • [6] Comparison of frequency doubling technology perimetry and achromatic standard automated perimetry in patients with migraine without aura and controls
    Goebel, K.
    Boyraz, M.
    Schroeder, A.
    Erb, C.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2008, 225 (08) : 718 - 722
  • [7] Spatial relationship of defects in frequency doubling technology perimetry and standard achromatic perimetry
    Pascual, JP
    Sample, PA
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U489 - U489
  • [8] Comparison of achromatic automated perimetry, short-wavelength automated perimetry and frequency doubling technology perimetry in the diagnosis of early glaucoma
    Milano, G
    Rossi, GCM
    Djeugoue, A
    Clemente, A
    PERIMETRY UPDATE 2000/2001, 2001, : 217 - 223
  • [9] Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
    Seong Ah Kim
    Chan Kee Park
    Hae-Young Lopilly Park
    Scientific Reports, 12
  • [10] Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
    Kim, Seong Ah
    Park, Chan Kee
    Park, Hae-Young Lopilly
    SCIENTIFIC REPORTS, 2022, 12 (01)