Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma

被引:9
|
作者
Serguhn, S [1 ]
Spiegel, D [1 ]
机构
[1] Univ Regensburg, Hosp Eye, D-93042 Regensburg, Germany
关键词
D O I
10.1007/s004170100277
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the reproducibility and efficacy of frequency-doubling perimetry (FDP), a new perimetric method for the detection of functional glaucomatous damage. Methods: Thirty-four glaucomatous eyes of 34 patients were examined by FDP (using the complete N30 threshold test of the Humphrey Frequency Perimeter) and by standard achromatic computerized perimetry (SAC; using the full threshold program 30-2 of the Humphrey Field Analyzer). Twenty-six of these eyes were examined twice by FDP. Reproducibility of repeated FDP was tested by the difference and the average of mean deviations (MD). Efficacy was studied by comparison of FDP and SAC using MD, as well as threshold results of FDP and corresponding SAG-tested areas. Spearman's rank correlation was calculated. Results: A significant correlation of repeated FDP examinations was found regarding MD [r=0.94, P <0.00001 (n=26)]. The reproducibility of FDP was independent of the glaucomatous damage [r=0.04, P=0.85 (n=26)], based on the correlation of the difference, and the average of MD. The MD of FDP and that of SAC showed a significant correlation [r-0.87, P <0.00001 (n=34)]. In advanced glaucoma, FDP tended to yield lower measurement values than SAG. Regarding corresponding areas, there was a significant correlation between threshold results of FDP-tested areas and the corresponding SAC testpoints [r=0.92, P <0.00001 (n=34)]. The conformity decreased from the peripheral to the central tested visual field. Conclusions: Sufficient reproducibility of FDP could be demonstrated in early and advanced glaucomatous visual field defects. Conformity between FDP and SAC was shown in terms of MD and threshold results of FDP-tested areas and corresponding SAG testpoints.
引用
收藏
页码:351 / 355
页数:5
相关论文
共 50 条
  • [41] Accuracy of glaucoma detection with frequency-doubling perimetry
    Trible, JR
    Schultz, RO
    Robinson, JC
    Rothe, TL
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (06) : 740 - 745
  • [42] Comparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes
    Hu, Rongrong
    Wang, Chenkun
    Racette, Lyne
    PLOS ONE, 2017, 12 (05):
  • [43] Screening for glaucoma in India with the frequency doubling perimetry test
    Mansberger, SL
    Johnson, CA
    Cioffi, GA
    Krishnadas, R
    Srinivasan, M
    Balamurugan, V
    Kim, U
    Smith, SD
    Wilkins, JH
    Gritz, DC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U492 - U492
  • [44] Sensitivity and specificity of flicker perimetry with Pulsar. Comparison with achromatic (white-on-white) perimetry in glaucoma patients
    Goebel, K.
    Erb, C.
    OPHTHALMOLOGE, 2013, 110 (02): : 141 - 145
  • [45] The ability of frequency doubling technology perimetry in the diagnosis of glaucoma
    Zhao, X
    Xu, L
    Zhang, R
    Ma, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U491 - U491
  • [46] Test-retest variability of frequency-doubling perimetry and conventional perimetry in glaucoma patients and normal subjects
    Chauhan, BC
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (03) : 648 - 656
  • [47] Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients
    Horn, FK
    Wakili, N
    Jünemann, AM
    Korth, M
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2002, 240 (08) : 658 - 665
  • [48] Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients
    Folkert K. Horn
    Nina Wakili
    Anselm M. Jünemann
    Matthias Korth
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2002, 240 : 658 - 665
  • [49] A comparison of diagnostic protocols for interpretation of frequency doubling perimetry visual fields in glaucoma
    Landers, John
    Sharma, Alok
    Goldberg, Ivan
    Graham, Stuart
    JOURNAL OF GLAUCOMA, 2006, 15 (04) : 310 - 314
  • [50] Relationship between second-generation frequency doubling technology and standard automated perimetry in patients with glaucoma
    Zarkovic, Andrea
    Mora, Justin
    McKelvie, James
    Gamble, Greg
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 35 (09): : 808 - 811