Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma

被引:9
|
作者
Serguhn, S [1 ]
Spiegel, D [1 ]
机构
[1] Univ Regensburg, Hosp Eye, D-93042 Regensburg, Germany
关键词
D O I
10.1007/s004170100277
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the reproducibility and efficacy of frequency-doubling perimetry (FDP), a new perimetric method for the detection of functional glaucomatous damage. Methods: Thirty-four glaucomatous eyes of 34 patients were examined by FDP (using the complete N30 threshold test of the Humphrey Frequency Perimeter) and by standard achromatic computerized perimetry (SAC; using the full threshold program 30-2 of the Humphrey Field Analyzer). Twenty-six of these eyes were examined twice by FDP. Reproducibility of repeated FDP was tested by the difference and the average of mean deviations (MD). Efficacy was studied by comparison of FDP and SAC using MD, as well as threshold results of FDP and corresponding SAG-tested areas. Spearman's rank correlation was calculated. Results: A significant correlation of repeated FDP examinations was found regarding MD [r=0.94, P <0.00001 (n=26)]. The reproducibility of FDP was independent of the glaucomatous damage [r=0.04, P=0.85 (n=26)], based on the correlation of the difference, and the average of MD. The MD of FDP and that of SAC showed a significant correlation [r-0.87, P <0.00001 (n=34)]. In advanced glaucoma, FDP tended to yield lower measurement values than SAG. Regarding corresponding areas, there was a significant correlation between threshold results of FDP-tested areas and the corresponding SAC testpoints [r=0.92, P <0.00001 (n=34)]. The conformity decreased from the peripheral to the central tested visual field. Conclusions: Sufficient reproducibility of FDP could be demonstrated in early and advanced glaucomatous visual field defects. Conformity between FDP and SAC was shown in terms of MD and threshold results of FDP-tested areas and corresponding SAG testpoints.
引用
收藏
页码:351 / 355
页数:5
相关论文
共 50 条
  • [31] Variability components of standard automated perimetry and frequency-doubling technology perimetry
    Spry, PGD
    Johnson, CA
    McKendrick, AM
    Turpin, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (06) : 1404 - 1410
  • [32] Comparison of frequency doubling and flicker defined form perimetry in early glaucoma
    Horn, Folkert K.
    Scharch, Vicki
    Mardin, Christian Y.
    Laemmer, Robert
    Kremers, Jan
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (05) : 937 - 946
  • [33] The Groningen Longitudinal Glaucoma Study. II. A prospective comparison of frequency doubling perimetry, the GDx nerve fibre analyser and standard automated perimetry in glaucoma suspect patients
    Jansonius, Nomdo M.
    Heeg, Govert P.
    ACTA OPHTHALMOLOGICA, 2009, 87 (04) : 429 - 432
  • [34] Correlation between SITA standard perimetry and frequency doubting perimetry in glaucoma
    Andrada, MT
    Ayala, E
    Anton, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U7 - U7
  • [35] Frequency doubling perimetry and short-wavelength automated perimetry to detect early glaucoma
    Leeprechanon, Narakorn
    Giaconi, Joann A.
    Manassakorn, Anita
    Hoffman, Douglas
    Caprioli, Joseph
    OPHTHALMOLOGY, 2007, 114 (05) : 931 - 937
  • [36] Comparison between GDx VCC parameter and achromatic perimetry in glaucoma patients
    Iester, Michele
    Perdicchi, Andrea
    De Feo, Fabio
    Fiesoletti, Enrica
    Orthopt T., C.
    Amodeo, Stefano
    Sanna, Giuseppe
    Leonardi, Antonella
    Calabria, Giovanni
    JOURNAL OF GLAUCOMA, 2006, 15 (04) : 281 - 285
  • [37] Comparison of Glaucoma Detection Performance of Binocular Perimetry Screening Program Using imo Perimetry With Frequency Doubling Technology
    Nishijima, Euido
    Hosaka, Daisuke
    Ogawa, Shumpei
    Itoh, Yoshinori
    Noro, Takahiko
    Okude, Sachiyo
    Sano, Kei
    Yoshikawa, Keiji
    Tatemichi, Masayuki
    Nakano, Tadashi
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2024, 13 (08):
  • [38] Short-wavelength automated perimetry and frequency-doubling technology perimetry in glaucoma
    Fogagnolo, Paolo
    Rossetti, Luca
    Ranno, Stefano
    Ferreras, Antonio
    Orzalesi, Nicola
    GLAUCOMA: AN OPEN WINDOW TO NEURODEGENERATION AND NEUROPROTECTION, 2008, 173 : 101 - 124
  • [39] Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma
    Siddiqui, MAR
    Azuara-Blanco, A
    Neville, S
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (12) : 1569 - 1571
  • [40] Frequency doubling perimetry
    Sponsel, WE
    Trigo, Y
    Hendricks, J
    Lloyd, C
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (01) : 155 - 156