Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma

被引:13
|
作者
Boden, C
Pascual, J
Medeiros, FA
Aihara, M
Weinreb, RN
Sample, PA
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Visual Funct Lab, La Jolla, CA 92093 USA
[3] Univ Tokyo, Dept Ophthalmol, Tokyo 113, Japan
关键词
D O I
10.1167/iovs.04-1108
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare full-threshold (FT) and SITA algorithms for standard automated perimetry (SAP) with frequency-doubling technology perimetry (FDT) in glaucoma, to help clinicians to relate results in patients who have had two or more of these tests during follow-up. METHODS. This study was a retrospective analysis of data from a longitudinal prospective study at the University of California, San Diego. One hundred four eyes of 104 patients with glaucomatous optic neuropathy detected by optic disc stereophotographs were included. All patients had standard perimetry (SITA and FT) and FDT within 3 months of each other. Global indices, abnormality and severity using two threshold algorithms of standard perimetry were compared with FDT. RESULTS. More eyes had normal visual fields by SAP-FT (57 eyes) than by either SAP-SITA (42 eyes) or FDT (45 eyes), although SAP-FT agreed more closely with FDT (kappa = 0.54 +/- 0.08) on the presence of a visual field defect than did SAP-SITA (kappa = 0.34 +/- 0.08). Correlations of FDT to standard perimetry global indices were similar regardless of the threshold strategy used for standard perimetry, yielding r(2) = 0.38-0.57 for SAP-FT with FDT, 0.36-0.54 for SAP-SITA with FDT. CONCLUSIONS. Despite many similarities of SAP-SITA and SAP-FT, switching the standard of comparison from SAP-FT to SAP-SITA changes the relationship to FDT with regard to visual field abnormality, but not correlations of global indices. FDT detected abnormal fields in more eyes than SAP-FT. SAP-FT tended to detect a subset of eyes found abnormal by FDT. Visual field defects may be detected more often by FDT and SAP-SITA in eyes with early visual field loss, but these two tests may not agree on which eyes show field loss in patients who undergo both tests at follow-up.
引用
收藏
页码:2433 / 2439
页数:7
相关论文
共 50 条
  • [21] Frequency Doubling Technology perimetry and standard automated perimetry in migraine
    Harle, DE
    Evans, BJW
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (03) : 233 - 239
  • [22] Comparison of frequency doubling perimetry to standard achromatic automated perimetry in glaucoma
    Serguhn, S
    Spiegel, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S842 - S842
  • [23] Different value scales between frequency-doubling technique and standard threshold perimetry
    Iester, M
    Traverso, CE
    Capris, P
    Vittone, P
    Zingirian, M
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2000, 78 : 26 - 27
  • [24] Comparison of matrix frequency-doubling technology perimetry and standard automated perimetry in monitoring the development of visual field defects for glaucoma suspect eyes
    Hu, Rongrong
    Wang, Chenkun
    Racette, Lyne
    PLOS ONE, 2017, 12 (05):
  • [25] Properties of threshold estimates from Full Threshold, SITA Standard, and SITA Fast perimetry
    Artes, PH
    Iwase, A
    Ohno, Y
    Kitazawa, Y
    Chauhan, BC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U491 - U491
  • [26] Learning effect in frequency-doubling technology perimetry in healthy subjects and glaucoma patients
    Giampani, AB
    Giampani, J
    Daher, L
    Lopes, JF
    Malta, RFS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U105 - U105
  • [27] Sensitivity and specificity of frequency doubling technology, tendency oriented perimetry, SITA standard, and SITA fast in patients undergoing automated perimetry for the first time
    Pierre, PTP
    Schimiti, RB
    Vasconcellos, JP
    Costa, VP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [28] Impact of cataract on the results of frequency-doubling technology perimetry
    Tanna, AP
    Abraham, C
    Lai, J
    Shen, J
    OPHTHALMOLOGY, 2004, 111 (08) : 1504 - 1507
  • [29] Selective Perimetry: Comparing Heidelberg Edge Perimetry and Frequency-Doubling Technology Perimetry in Detecting Glaucomatous Loss
    Fingeret, M.
    Klein, R.
    Sloane, A.
    Canellos, E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [30] Structure-Function Relationship between Frequency-Doubling Technology Perimetry and Optical Coherence Tomography in Glaucoma
    Fuertes-Lazaro, Isabel
    Sanchez-Cano, Ana
    Ferreras, Antonio
    Ferrandez, Blanca
    Calvo, Pilar
    Abadia, Beatriz
    Otin, Sofia
    Pablo, Luis E.
    OPHTHALMOLOGICA, 2014, 232 (04) : 230 - 238