Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma

被引:13
|
作者
Boden, C
Pascual, J
Medeiros, FA
Aihara, M
Weinreb, RN
Sample, PA
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Visual Funct Lab, La Jolla, CA 92093 USA
[3] Univ Tokyo, Dept Ophthalmol, Tokyo 113, Japan
关键词
D O I
10.1167/iovs.04-1108
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare full-threshold (FT) and SITA algorithms for standard automated perimetry (SAP) with frequency-doubling technology perimetry (FDT) in glaucoma, to help clinicians to relate results in patients who have had two or more of these tests during follow-up. METHODS. This study was a retrospective analysis of data from a longitudinal prospective study at the University of California, San Diego. One hundred four eyes of 104 patients with glaucomatous optic neuropathy detected by optic disc stereophotographs were included. All patients had standard perimetry (SITA and FT) and FDT within 3 months of each other. Global indices, abnormality and severity using two threshold algorithms of standard perimetry were compared with FDT. RESULTS. More eyes had normal visual fields by SAP-FT (57 eyes) than by either SAP-SITA (42 eyes) or FDT (45 eyes), although SAP-FT agreed more closely with FDT (kappa = 0.54 +/- 0.08) on the presence of a visual field defect than did SAP-SITA (kappa = 0.34 +/- 0.08). Correlations of FDT to standard perimetry global indices were similar regardless of the threshold strategy used for standard perimetry, yielding r(2) = 0.38-0.57 for SAP-FT with FDT, 0.36-0.54 for SAP-SITA with FDT. CONCLUSIONS. Despite many similarities of SAP-SITA and SAP-FT, switching the standard of comparison from SAP-FT to SAP-SITA changes the relationship to FDT with regard to visual field abnormality, but not correlations of global indices. FDT detected abnormal fields in more eyes than SAP-FT. SAP-FT tended to detect a subset of eyes found abnormal by FDT. Visual field defects may be detected more often by FDT and SAP-SITA in eyes with early visual field loss, but these two tests may not agree on which eyes show field loss in patients who undergo both tests at follow-up.
引用
收藏
页码:2433 / 2439
页数:7
相关论文
共 50 条
  • [41] Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients
    Folkert K. Horn
    Nina Wakili
    Anselm M. Jünemann
    Matthias Korth
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2002, 240 : 658 - 665
  • [42] Testing for glaucoma with frequency-doubling perimetry in normals, ocular hypertensives, and glaucoma patients
    Horn, FK
    Wakili, N
    Jünemann, AM
    Korth, M
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2002, 240 (08) : 658 - 665
  • [43] Predicting conversion to glaucoma using standard automated perimetry and frequency doubling technology
    Takahashi, Genichiro
    Demirel, Shaban
    Johnson, Chris A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (04) : 797 - 803
  • [44] Predicting conversion to glaucoma using standard automated perimetry and frequency doubling technology
    Genichiro Takahashi
    Shaban Demirel
    Chris A. Johnson
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2017, 255 : 797 - 803
  • [45] Test-retest variability of frequency-doubling perimetry and conventional perimetry in glaucoma patients and normal subjects
    Chauhan, BC
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (03) : 648 - 656
  • [46] Cumulative defect (Bebie) curves for frequency-doubling technology perimetry
    Johnson, CA
    Spry, PGD
    PERIMETRY UPDATE 2002/2003, 2004, : 3 - 12
  • [47] Frequency-doubling technology perimetry and multifocal visual evoked potential in glaucoma, suspected glaucoma, and control patients
    Kanadani, Fabio N.
    Mello, Paulo A. A.
    Dorairaj, Syril K.
    Kanadani, Tereza C. M.
    CLINICAL OPHTHALMOLOGY, 2014, 8 : 1323 - 1330
  • [48] Rarebit and frequency-doubling technology perimetry in children and young adults
    Martin, L
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2005, 83 (06): : 670 - 677
  • [49] The ability of frequency doubling technology perimetry in the diagnosis of glaucoma
    Zhao, X
    Xu, L
    Zhang, R
    Ma, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U491 - U491
  • [50] Insights for mfVEPs from perimetry using large spatial frequency-doubling and near frequency-doubling stimuli in glaucoma
    Abdullah, Siti Nurliyana
    Sanderson, Gordon F.
    Husni, Mohd Aziz
    Maddess, Ted
    DOCUMENTA OPHTHALMOLOGICA, 2020, 141 (01) : 45 - 55