Rationale and feasibility of the atrioventricular single-lead ICD systems with a floating atrial dipole (DX) in clinical practice

被引:1
|
作者
Vamos, Mate [1 ]
Nemeth, Marianna [2 ]
Balazs, Tibor [3 ]
Zima, Endre [4 ]
Duray, Gabor Zoltan [5 ]
机构
[1] Univ Szeged, Dept Internal Med, Cardiac Electrophysiol Div, Semmelweis U 8, H-6725 Szeged, Hungary
[2] Univ Pecs, Heart Inst, Pecs, Hungary
[3] Biotron Hungary Ltd, Budapest, Hungary
[4] Semmelweis Univ, Heart & Vasc Ctr, Budapest, Hungary
[5] Hungarian Def Forces, Dept Cardiol, Med Ctr, Budapest, Hungary
关键词
ICD; Implantable cardioverter defibrillator; Single-lead ICD; VDD; DX; Two-lead CRT-D; CRT-DX; CARDIAC RESYNCHRONIZATION THERAPY; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; EXPERT CONSENSUS STATEMENT; DUAL-CHAMBER; ESC GUIDELINES; HEART-FAILURE; SENSING DIPOLE; RHYTHM; RISK; COMPLICATIONS;
D O I
10.1016/j.tcm.2021.01.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiac implantable electronic devices establish proper therapy for the prevention of sudden cardiac death, significantly reducing the morbidity and mortality of patients with arrhythmias and heart failure. It is well-known that the number of electrodes increases the risk of complications. To preserve the benefit of atrial sensing without the need to implant an additional lead, a single-lead ICD system with a floating atrial dipole (DX ICD lead) has been developed. Besides all of the potential benefits, the necessity of a reliable and stable atrial sensing via the floating dipole could be the main concern against the use of this lead type. In the current generation of DX devices, the specially filtered atrial signal seems to be high enough and stable over time, which is crucial in the early detection of atrial arrhythmias, discrimination between different forms of tachycardias in order to prevent inappropriate ICD therapy, and achieving an optimal atrioventricular and interventricular synchrony in patients with a two-lead CRT-DX system. The present review summarizes the benefits and potential drawbacks of the DX ICD systems based on the available literature, furthermore, proposes an evidence-based algorithm of ICD type selection. (c) 2021 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ )
引用
收藏
页码:84 / 89
页数:6
相关论文
共 42 条
  • [31] Single lead implantable cardioverter-defibrillator lead system with a atrial sensing dipole (Dx-AICD technology): 1-year follow-up
    Sangoi, Parin
    Chandh, R. Deep
    Mullasari, A.
    Pandurangi, U.
    EUROPEAN JOURNAL OF HEART FAILURE, 2019, 21 : 37 - 37
  • [32] Feasibility of dual-chamber (DDD) pacing via a single-pass (VDD) pacing lead employing a floating atrial ring (dipole): Case series, future considerations, and refinements
    Kassotis, J
    Voigt, L
    Mongwa, M
    Reddy, CVR
    ANGIOLOGY, 2005, 56 (03) : 323 - 329
  • [33] Feasibility of atrial sensing via a free-floating single-pass defibrillation lead for dual-chamber defibrillators
    Schuchert, A
    Niehaus, M
    Binner, L
    Belke, R
    Meinertz, T
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2003, 8 (03) : 209 - 214
  • [34] Feasibility of Atrial Sensing Via a Free-Floating Single-Pass Defibrillation Lead for Dual-Chamber Defibrillators
    Andreas Schuchert
    Michael Niehaus
    Ludwig Binner
    Roberto Belke
    Thomas Meinertz
    Journal of Interventional Cardiac Electrophysiology, 2003, 8 : 209 - 214
  • [35] Clinical Factors Associated with Atrial Fibrillation Detection on Single-Time Point Screening Using a Hand-Held Single-Lead ECG Device
    Boriani, Giuseppe
    Palmisano, Pietro
    Malavasi, Vincenzo Livio
    Fantecchi, Elisa
    Vitolo, Marco
    Bonini, Niccolo'
    Imberti, Jacopo F.
    Valenti, Anna Chiara
    Schnabel, Renate B.
    Freedman, Ben
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (04) : 1 - 13
  • [36] LONG-TERM STABILITY OF P-WAVE SENSING IN SINGLE-LEAD VDDR PACING - CLINICAL VERSUS SUBCLINICAL ATRIAL UNDERSENSING
    LAU, CP
    TAI, YT
    LEUNG, SK
    LEUNG, WH
    CHUNG, FLW
    LEE, ISF
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 1849 - 1853
  • [37] Comparison of 6 different single-lead VDD pacemaker systems in maintainance of atrial sensitivity at 1-year follow-up
    Chiladakis, J
    Aggelopoulos, G
    Hahalis, G
    Simeonidou, E
    Alexopoulos, D
    Manolis, AS
    EUROPEAN HEART JOURNAL, 2000, 21 : 681 - 681
  • [38] Single lead catheter of implantable cardioverter-defibrillator with floating atrial sensing dipole implanted via persistent left superior vena cava
    Malagu, Michele
    Toselli, Tiziano
    Bertini, Matteo
    WORLD JOURNAL OF CARDIOLOGY, 2016, 8 (04): : 323 - 326
  • [39] Clinical evaluation of a prototype passive fixation dual chamber single pass lead for dual chamber ICD systems
    Butter, C
    Auricchio, A
    Schwarz, T
    Fleck, E
    Schubert, B
    Hsu, W
    Michel, U
    Neuzner, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (01): : 169 - 173
  • [40] Use of a novel smartphone based single-lead electro-cardiogram device in clinical practice to evaluate heart rhythm in horses - a case series
    Spitale, Diletta
    Cicogna, Maria
    Porciello, Francesco
    Colonnelli, Michela
    Caivano, Domenico
    PFERDEHEILKUNDE, 2024, 40 (02): : 149 - 152