Feasibility of atrial sensing via a free-floating single-pass defibrillation lead for dual-chamber defibrillators

被引:8
|
作者
Schuchert, A
Niehaus, M
Binner, L
Belke, R
Meinertz, T
机构
[1] Univ Hosp Eppendorf, Dept Cardiol, Med Clin, Hamburg, Germany
[2] Hannover Med Sch, Berlin, Germany
[3] Univ Hosp Ulm, Berlin, Germany
[4] BIOTRONIK, Berlin, Germany
关键词
implantable cardioverter defibrillator (ICD); transvenous defibrillation lead; atrial fibrillation; ICD implantation;
D O I
10.1023/A:1023921322671
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Detection and misclassification of rapidly conducted atrial fibrillation (AF) and marked sinus tachycardia by implantable cardioverter defibrillators (ICD) can result in the delivery of inappropriate therapies. Continuous atrial sensing may improve the differentiation between supraventricular and ventricular tachycardia. The present approach is to implant a separate atrial pacing lead connected to a dual-chamber defibrillator. We hypothesized that a free-floating single-pass defibrillation lead reliably senses the atrial electrical activity. The aim of the study was to assess during implantation the efficacy of a custom-built free-floating single-pass defibrillation lead and to record sinus rhythm (SR), induced AF, and atrial flutter (Afl). Methods: The free-floating single-pass defibrillation lead ( Biotronik, Berlin, Germany) had an atrial bipole with 10 mm spacing and a distance between the atrial bipole and the electrode tip of 13.5, 15 or 17- cm. The lead was temporarily implanted in 15 patients during an ICD implantation. Fifteen seconds recordings were made during SR and after the induction of AF and Afl as well as during induced ventricular fibrillation. The amplitude and the time that the amplitude was less than 0.3 mV were assessed. Results: The amplitude during SR (2.1 +/- 1.4 mV) was significantly higher compared with the amplitudes for Afl (1.3 +/- 0.5 mV; p < 0.02) and AF (0.7 +/- 0.5 mV; p < 0.001). Low amplitudes were not observed during SR and rarely during Afl ( 1.6 +/- 3.1%), but they were observed 19.9 +/- 15.9% of the time during AF ( p < 0.05). The correlation coefficients between SR and AF amplitudes were r = 0.25, between SR and Afl amplitudes r = 0.31, and between AF and Afl amplitudes r = 0.41. During the ventricular fibrillation conversion test 9 patients were in continuous SR. The P-wave amplitude before the induction of ventricular fibrillation was 2.1 +/- 1.4 mV. The signal during ventricular fibrillation decreased to 1.1 +/- 0.7 mV and increased immediately after the termination of ventricular fibrillation to 1.6 +/- 0.8 mV. Conclusions: The recorded unfiltered signals indicate that SR as well as AF and Afl can immediately be detected after the implantation of the new free-floating single-pass defibrillation lead. High signal amplitude during SR did not predict high amplitude during AF or Afl. During induced ventricular fibrillation the P-wave amplitude decreased intermittently.
引用
收藏
页码:209 / 214
页数:6
相关论文
共 28 条
  • [1] Feasibility of Atrial Sensing Via a Free-Floating Single-Pass Defibrillation Lead for Dual-Chamber Defibrillators
    Andreas Schuchert
    Michael Niehaus
    Ludwig Binner
    Roberto Belke
    Thomas Meinertz
    Journal of Interventional Cardiac Electrophysiology, 2003, 8 : 209 - 214
  • [2] Comparison of patients with and without atrial fibrillation after implantation of a dual-chamber defibrillator using a defibrillation lead with free-floating atrial bipole
    Schuchert, A
    Schmitz, D
    Lemke, B
    Bondke, HJ
    Zerm, T
    Wiegand, U
    Tiroke, A
    Pavón, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 115A - 115A
  • [3] Clinical experience with a single-pass lead for dual-chamber ICDs
    Böcker, D
    Gradaus, R
    Osswald, S
    Cron, T
    Gommer, ED
    EUROPEAN HEART JOURNAL, 2000, 21 : 470 - 470
  • [4] Detection of tachyarrhythmia with a dual chamber defibrillator connected to a defibrillation lead with a free-floating atrial bipole
    Schuchert, A
    Lemke, B
    Schmitz, D
    Bondke, HJ
    Zerm, T
    CIRCULATION, 2002, 106 (19) : 668 - 668
  • [5] Detection of tachyarrhythmia with a dual chamber defibrillator connected to a defibrillation lead with a free-floating atrial bipole
    Schuchert, A
    Lemke, B
    Schmitz, D
    Wiegand, U
    Bondke, HJ
    Zerm, T
    Aydin, MA
    Meinertz, T
    EUROPEAN HEART JOURNAL, 2002, 23 : 357 - 357
  • [6] Feasibility of dual-chamber (DDD) pacing via a single-pass (VDD) pacing lead employing a floating atrial ring (dipole): Case series, future considerations, and refinements
    Kassotis, J
    Voigt, L
    Mongwa, M
    Reddy, CVR
    ANGIOLOGY, 2005, 56 (03) : 323 - 329
  • [7] Atrial sensing performance of a recently developed defibrillation lead with a free-floating atrial dipole connected to a dual chamber defibrillator with enhanced atrial sensing characteristics
    Zerm, T
    Schmitz, D
    Bondke, HJ
    Lemke, B
    Wiegand, U
    Troke, A
    Pavón, M
    Schuchert, A
    CIRCULATION, 2003, 108 (17) : 325 - 325
  • [8] Atrial sensing performance of a recently developed defibrillation lead with a free-floating atrial dipole connected to a single chamber defibrillator with enhanced atrial sensing characteristics
    Zerm, T
    Schmitz, D
    Bondke, HJ
    Lemke, B
    Wiegand, U
    Tiroke, A
    Mitzenheim, S
    Schuchert, A
    EUROPEAN HEART JOURNAL, 2003, 24 : 275 - 275
  • [9] Implantation of a dual chamber pacing and sensing single pass defibrillation lead
    Gradaus, R
    Block, M
    Dorszewski, A
    Schriever, C
    Hammel, D
    Scheld, HH
    Borggrefe, M
    Breithardt, G
    Böcker, D
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (04): : 416 - 423
  • [10] EXPERIENCE WITH A SINGLE-PASS ATRIAL DEFIBRILLATION LEAD SYSTEM
    AYERS, GM
    TACKER, WA
    GONZALEZ, X
    SCHOENLEIN, WE
    JANAS, WT
    ALTERNESS, CA
    CIRCULATION, 1995, 92 (08) : 2256 - 2256