Rationale and feasibility of the atrioventricular single-lead ICD systems with a floating atrial dipole (DX) in clinical practice

被引:1
|
作者
Vamos, Mate [1 ]
Nemeth, Marianna [2 ]
Balazs, Tibor [3 ]
Zima, Endre [4 ]
Duray, Gabor Zoltan [5 ]
机构
[1] Univ Szeged, Dept Internal Med, Cardiac Electrophysiol Div, Semmelweis U 8, H-6725 Szeged, Hungary
[2] Univ Pecs, Heart Inst, Pecs, Hungary
[3] Biotron Hungary Ltd, Budapest, Hungary
[4] Semmelweis Univ, Heart & Vasc Ctr, Budapest, Hungary
[5] Hungarian Def Forces, Dept Cardiol, Med Ctr, Budapest, Hungary
关键词
ICD; Implantable cardioverter defibrillator; Single-lead ICD; VDD; DX; Two-lead CRT-D; CRT-DX; CARDIAC RESYNCHRONIZATION THERAPY; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; EXPERT CONSENSUS STATEMENT; DUAL-CHAMBER; ESC GUIDELINES; HEART-FAILURE; SENSING DIPOLE; RHYTHM; RISK; COMPLICATIONS;
D O I
10.1016/j.tcm.2021.01.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiac implantable electronic devices establish proper therapy for the prevention of sudden cardiac death, significantly reducing the morbidity and mortality of patients with arrhythmias and heart failure. It is well-known that the number of electrodes increases the risk of complications. To preserve the benefit of atrial sensing without the need to implant an additional lead, a single-lead ICD system with a floating atrial dipole (DX ICD lead) has been developed. Besides all of the potential benefits, the necessity of a reliable and stable atrial sensing via the floating dipole could be the main concern against the use of this lead type. In the current generation of DX devices, the specially filtered atrial signal seems to be high enough and stable over time, which is crucial in the early detection of atrial arrhythmias, discrimination between different forms of tachycardias in order to prevent inappropriate ICD therapy, and achieving an optimal atrioventricular and interventricular synchrony in patients with a two-lead CRT-DX system. The present review summarizes the benefits and potential drawbacks of the DX ICD systems based on the available literature, furthermore, proposes an evidence-based algorithm of ICD type selection. (c) 2021 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ )
引用
收藏
页码:84 / 89
页数:6
相关论文
共 42 条
  • [21] Comparison of the optimal position of the atrial electrodes in two different single-lead VDD pacing systems
    Karaoguz, R
    Guldal, M
    Ertas, F
    Oral, D
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 573 - 577
  • [22] Determinants of atrial sensing in VDD single-lead systems [Determinanten des atrialen sensings bei VDD-single-lead-systemen]
    Israel C.W.
    Herzschrittmachertherapie und Elektrophysiologie, 1998, 9 (4): : 234 - 247
  • [23] DDD pacing using a single A-V lead with atrial floating dipole and overlapping biphasic stimulation
    DelGiudice, G
    Frabetti, L
    Cioffi, L
    Cornacchia, D
    Mangiameli, S
    Audoglio, R
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 851 - 856
  • [24] Impact of Clinical Expertise and Choice of Wearable Device on Accuracy to detect Atrial Fibrillation via Single-lead ECGs
    Weidlich, Simon
    Mannhart, Diego
    Teodor, Serban
    Krisai, Philipp
    Knecht, Sven
    de lavallaz, Jeanne du Fay
    Schar, Beat
    Osswald, Stefan
    Kuhne, Michael
    Sticherling, Christian
    Badertscher, Patrick
    SWISS MEDICAL WEEKLY, 2023, 153 : 45S - 45S
  • [25] The efficacy of single-lead implantable cardioverter-defibrillator with atrial sensing dipole to detect atrial fibrillation and to reduce inappropriate therapy according to atrial sensing ON or OFF: Rationale and design of the SMART-CONTROL study, a prospective multicenter randomized trial
    Gwag, Hye Bin
    Kim, Hye Ree
    Park, Seung-Jung
    Kim, Juwon
    Chung, Tae Wan
    Choi, Ji-Hoon
    Kim, Ju Youn
    Park, Kyoung-Min
    On, Young Keun
    Kim, June Soo
    AMERICAN HEART JOURNAL, 2022, 251 : 25 - 31
  • [26] Atrial sensing performance of a recently developed defibrillation lead with a free-floating atrial dipole connected to a single chamber defibrillator with enhanced atrial sensing characteristics
    Zerm, T
    Schmitz, D
    Bondke, HJ
    Lemke, B
    Wiegand, U
    Tiroke, A
    Mitzenheim, S
    Schuchert, A
    EUROPEAN HEART JOURNAL, 2003, 24 : 275 - 275
  • [27] Implanting strategy of the atrial dipole impacts atrial sensing performance of single-lead VDD-pacemakers. Results of the Saphir Multicenter Follow-up Study.
    Wiegand, UK
    Nowak, B
    Reisp, U
    Peiffer, T
    Potratz, J
    CIRCULATION, 2000, 102 (18) : 714 - 714
  • [28] Accuracy in detecting atrial fibrillation in single-lead ECGs: an online survey comparing the influence of clinical expertise and smart devices
    Weidlich, Simon
    Mannhart, Diego
    Serban, Teodor
    Krisai, Philipp
    Knecht, Sven
    de Lavallaz, Jeanne du Fay
    Muller, Tatjana
    Schaer, Beat
    Osswald, Stefan
    Kuhne, Michael
    Sticherling, Christian
    Badertscher, Patrick
    SWISS MEDICAL WEEKLY, 2023, 153
  • [29] Detection of Sub-Clinical Atrial Fibrillation Using A VDD-ICD Lead in Amulticenter Randomized Trial: The DX-AF Study
    Crystal, Eugene
    Janmohamed, Amir
    Ayala-Paredes, Felix
    Sturmer, Marcio
    Toal, Satish
    Sarrazin, Md Jean-Francois
    Thorpe, Kevin E.
    Sterns, Laurence D.
    Healey, Jeffrey S.
    Shurrab, Mohammed
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 : S31 - S31
  • [30] LONG-TERM RELIABILITY OF SINGLE-LEAD ATRIAL SYNCHRONOUS PACING SYSTEMS USING CLOSELY SPACED ATRIAL DIPOLES - 5-YEAR EXPERIENCE
    ANSANI, L
    PERCOCO, GF
    GUARDIGLI, G
    TOSELLI, T
    ANTONIOLI, GE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 1865 - 1869