Single-sweep pulmonary vein isolation using the new third-generation laser balloon-Evolution in ablation style using endoscopic ablation system

被引:7
|
作者
Tohoku, Shota [1 ]
Bordignon, Stefano [1 ]
Chen, Shaojie [1 ,2 ]
Zanchi, Simone [1 ]
Bianchini, Lorenzo [1 ]
Trolese, Luca [3 ]
Operhalski, Felix [4 ]
Urbanek, Lukas [1 ]
Chun, K. R. Julian [1 ,2 ]
Schmidt, Boris [1 ,4 ]
机构
[1] Cardioangiol Ctr Bethanien, Wilhelm Epstein Str 4, D-60431 Frankfurt, Germany
[2] Univ Lubeck, Die Sekt Med, Lubeck, Germany
[3] Univ Herzzentrum Freiburg Bad Krozingen, Klin Kardiol & Angiol 1, Freiburg, Germany
[4] Univ Klinikum Frankfurt, Med Klin 3, Klin Kardiol, Frankfurt, Germany
关键词
atrial fibrillation; balloon ablation; endoscopic ablation system; laser balloon; pulmonary vein isolation; RADIOFREQUENCY ABLATION; CRYOBALLOON;
D O I
10.1111/jce.15245
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The endoscopic ablation system (EAS) is an established ablation device for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). The novel X3 EAS is now equipped with a contiguous circumferential ablation mode (RAPID mode). Aim To determine the feasibility of single-shot fashioned ablation using X3. Methods Consecutive patients who underwent AF ablation using X3 were enrolled. We assessed the acute procedural data focusing on "Single-sweep PVI" defined as successful PVI with a single RAPID mode energy application, and on "first-pass isolation" defined as successful PVI after initial circular lesion set. Results One hundred AF patients (56% male, age: 68 +/- 10 years, 66% paroxysmal AF) were analyzed. A total of 379 of 383 PVs (99%) were isolated with X3. Single-sweep PVI and first-pass-isolation were achieved in 214 PVs (56%) and in 362 PVs (95%), respectively. Single-sweep PVI rates varied across PVs with higher rates at the superior PVs (61.2% vs. inferior PVs: 49.5%, p = .0239) and at PVs with maximal ostial diameter <24 mm (57.6% vs. >24 mm: 36.8%, p = .0151). The mean total procedure and fluoroscopy times were 43.0 +/- 10 and 4.0 +/- 2 min, respectively. In none of the patients an acute thromboembolic event (stroke or transient ischemic attack) or a pericardial effusion/tamponade occurred. A single transient phrenic nerve palsy was observed. Conclusion The new X3 EAS allows for single-shot fashioned ablation in terms of single-sweep PVI in half or more of PVs. The new RAPID ablation mode leads to an improved rate of first-pass isolation associated with very short procedure times without compromising safety.
引用
收藏
页码:2923 / 2932
页数:10
相关论文
共 50 条
  • [41] Esophageal ulcers secondary to cryoenergy after pulmonary vein ablation using the second-generation balloon
    Alvarez-Acosta, Luis
    Quijada-Fumero, Alejandro
    Pimienta-Gonzalez, Raquel
    Hernandez-Afonso, Julio S.
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2018, 46 (03): : 221 - 222
  • [42] What Is the Acute Antral Lesion Size After Pulmonary Vein Isolation Using Different Balloon Ablation Technologies?
    Perrotta, Laura
    Konstantinou, Athanasios
    Bordignon, Stefano
    Fuernkranz, Alexander
    Dugo, Daniela
    Chun, K. R. Julian
    Schmidt, Boris
    CIRCULATION JOURNAL, 2017, 81 (02) : 172 - 179
  • [43] First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation
    Natale, A
    Pisano, E
    Shewchik, J
    Bash, D
    Fanelli, R
    Potenza, D
    Santarelli, P
    Schweikert, R
    White, R
    Saliba, W
    Kanagaratnam, L
    Tchou, P
    Lesh, M
    CIRCULATION, 2000, 102 (16) : 1879 - 1882
  • [44] Fiberoptic balloon catheter ablation of pulmonary vein ostia in pigs using photonic energy delivery with diode laser
    Lemery, R
    Veinot, J
    Tang, A
    Green, M
    Farr, N
    Baxter, L
    McIntyre, J
    Sinofsky, E
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 88A - 89A
  • [45] Fiberoptic balloon catheter ablation of pulmonary vein ostia in pigs using photonic energy delivery with diode laser
    Lemery, R
    Veinot, JP
    Tang, ASL
    Green, M
    Farr, N
    Baxter, L
    McIntyre, J
    Sinofsky, E
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (01): : 32 - 36
  • [46] Long-term single-procedure clinical results with an endoscopic balloon ablation catheter for pulmonary vein isolation in patients with atrial fibrillation
    Reddy, Vivek
    Neuzil, Petr
    Themistoclakis, Sakis
    Bonso, Aldo
    Rossillo, Antonio
    Raviele, Antonio
    Saliba, Walid
    Schwiekert, Robert
    Ernst, Sabine
    Kuck, Karl-Heinz
    Ruskin, Jeremy
    Natale, Andrea
    CIRCULATION, 2006, 114 (18) : 747 - 748
  • [47] Repeat pulmonary vein isolation and anterior line ablation using a novel point-by-point pulsed-field ablation system
    Wenzel, Jan-Per
    Lemoine, Marc D.
    Rottner, Laura
    My, Ilaria
    Moser, Fabian
    Obergassel, Julius
    Nies, Moritz
    Riess, Jan
    Ismaili, Djemail
    Nikorowitsch, Julius
    Ouyang, Feifan
    Kirchhof, Paulus
    Rillig, Andreas
    Metzner, Andreas
    Reissmann, Bruno
    HEART RHYTHM, 2024, 21 (03) : 250 - 257
  • [48] Nonthermal Point-by-Point Pulmonary Vein Isolation Using a Novel Pulsed Field Ablation System
    Wenzel, Jan-Per
    Lemoine, Marc D.
    Rottner, Laura
    My, Ilaria
    Moser, Fabian
    Obergassel, Julius
    Nies, Moritz
    Riess, Jan
    Ismaili, Djemail
    Nikorowitsch, Julius
    Ouyang, Feifan
    Kirchhof, Paulus
    Rillig, Andreas
    Metzner, Andreas
    Reissmann, Bruno
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2023, 16 (09):
  • [49] Acute Results of Pulmonary Vein Isolation Using a Single Combined Mapping and Ablation Catheter and Conventional Fluoroscopy Only
    Hofmann, Rebell
    Steinwender, Clemens
    Hoenig, Simon
    Leisch, Franz
    CIRCULATION, 2008, 118 (18) : S831 - S831
  • [50] Visually-guided pulmonary vein isolation using a balloon ablation catheter to treat patients with paroxysmal atrial fibrillation: One-year clincial outcome following a single ablation procedure
    Reddy, Vivek Y.
    Neuzil, Petr
    Themistoclakis, Sakis
    Bonso, Aldo
    Rossillo, Antonio
    Raviele, Antonio
    Saliba, Walid
    Schwiekerl, Robert
    Ernst, Sabine
    Kuck, Karl-Heinz
    Ruskin, Jeremy N.
    Natale, Andrea
    CIRCULATION, 2007, 116 (16) : 536 - 536