Single-sweep pulmonary vein isolation using the new third-generation laser balloon-Evolution in ablation style using endoscopic ablation system

被引:7
|
作者
Tohoku, Shota [1 ]
Bordignon, Stefano [1 ]
Chen, Shaojie [1 ,2 ]
Zanchi, Simone [1 ]
Bianchini, Lorenzo [1 ]
Trolese, Luca [3 ]
Operhalski, Felix [4 ]
Urbanek, Lukas [1 ]
Chun, K. R. Julian [1 ,2 ]
Schmidt, Boris [1 ,4 ]
机构
[1] Cardioangiol Ctr Bethanien, Wilhelm Epstein Str 4, D-60431 Frankfurt, Germany
[2] Univ Lubeck, Die Sekt Med, Lubeck, Germany
[3] Univ Herzzentrum Freiburg Bad Krozingen, Klin Kardiol & Angiol 1, Freiburg, Germany
[4] Univ Klinikum Frankfurt, Med Klin 3, Klin Kardiol, Frankfurt, Germany
关键词
atrial fibrillation; balloon ablation; endoscopic ablation system; laser balloon; pulmonary vein isolation; RADIOFREQUENCY ABLATION; CRYOBALLOON;
D O I
10.1111/jce.15245
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The endoscopic ablation system (EAS) is an established ablation device for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). The novel X3 EAS is now equipped with a contiguous circumferential ablation mode (RAPID mode). Aim To determine the feasibility of single-shot fashioned ablation using X3. Methods Consecutive patients who underwent AF ablation using X3 were enrolled. We assessed the acute procedural data focusing on "Single-sweep PVI" defined as successful PVI with a single RAPID mode energy application, and on "first-pass isolation" defined as successful PVI after initial circular lesion set. Results One hundred AF patients (56% male, age: 68 +/- 10 years, 66% paroxysmal AF) were analyzed. A total of 379 of 383 PVs (99%) were isolated with X3. Single-sweep PVI and first-pass-isolation were achieved in 214 PVs (56%) and in 362 PVs (95%), respectively. Single-sweep PVI rates varied across PVs with higher rates at the superior PVs (61.2% vs. inferior PVs: 49.5%, p = .0239) and at PVs with maximal ostial diameter <24 mm (57.6% vs. >24 mm: 36.8%, p = .0151). The mean total procedure and fluoroscopy times were 43.0 +/- 10 and 4.0 +/- 2 min, respectively. In none of the patients an acute thromboembolic event (stroke or transient ischemic attack) or a pericardial effusion/tamponade occurred. A single transient phrenic nerve palsy was observed. Conclusion The new X3 EAS allows for single-shot fashioned ablation in terms of single-sweep PVI in half or more of PVs. The new RAPID ablation mode leads to an improved rate of first-pass isolation associated with very short procedure times without compromising safety.
引用
收藏
页码:2923 / 2932
页数:10
相关论文
共 50 条
  • [21] Pulmonary vein isolation using a circumferential laser ablation in a swine model
    Schurmann, A.
    Schulz, D.
    Valderrabano, M.
    EUROPEAN HEART JOURNAL, 2014, 35 : 591 - 591
  • [22] Initial results of pulmonary vein isolation using the novel third-generation cryoballoon
    Fuernkranz, A.
    Bordignon, S.
    Bologna, F.
    Perrotta, L.
    Dugo, D.
    Schmidt, B.
    Chun, J.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1090 - 1090
  • [23] Procedural characteristics of pulmonary vein isolation using the novel third-generation cryoballoon
    Fuernkranz, Alexander
    Bologna, Fabrizio
    Bordignon, Stefano
    Perrotta, Laura
    Dugo, Daniela
    Schmidt, Boris
    Chun, Julian K. R.
    EUROPACE, 2016, 18 (12): : 1795 - 1800
  • [24] SAFETY AND EFFICACY PROFILE OF PULMONARY VEIN ISOLATION USING CRYOBALLOON ABLATION VERSUS LASER BALLOON ABLATION FOR PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATION
    Magdon, Dorota
    Mounir, Abdulghani
    Ali, Mahmoud
    Erickson, Lynn
    Adefisoye, James
    Kieu, Andy
    Malik, Abdullah
    Ajam, Tarek
    Premjee, Mohammed M.
    Jahangir, Arshad
    Mortada, M. Eyman
    Bhatia, Atul
    Niazi, Imran
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 68 - 68
  • [25] Visually Guided Pulmonary Vein Isolation Using a Compliant Endoscopic Laser Balloon
    Gerstenfeld, Edward P.
    Moss, Joshua
    Michele, John
    CIRCULATION, 2009, 120 (18) : S657 - S658
  • [26] Initial Experience With a New Ablation Catheter Using Laser Energy for Electrical Pulmonary Vein Isolation
    Osca, Joaquin
    Cano, Oscar
    Andres, Ana
    Alonso, Pau
    Jose Sancho-Tello, Maria
    Olague, Jose
    REVISTA ESPANOLA DE CARDIOLOGIA, 2014, 67 (12): : 1061 - 1062
  • [27] Short tip–more function? Atrial fibrillation ablation using the novel third-generation cryoballoon in resected pulmonary vein
    Shaojie Chen
    Boris Schmidt
    Stefano Bordignon
    Fabrizio Bologna
    K. R. Julian Chun
    International Journal of Arrhythmia, 20 (1)
  • [28] First experience with circumferential pulmonary vein ablation using a laser energy balloon catheter
    Su, WW
    Johnson, SB
    Packer, DL
    CIRCULATION, 2001, 104 (17) : 567 - 567
  • [29] First experience with circumferential pulmonary vein ablation using a laser energy balloon catheter
    Su, WW
    Johnson, SB
    Packer, DL
    EUROPEAN HEART JOURNAL, 2002, 23 : 522 - 522
  • [30] Pulmonary Vein Isolation Using the Visually Guided Laser Balloon A Prospective, Multicenter, and Randomized Comparison to Standard Radiofrequency Ablation
    Dukkipati, Srinivas R.
    Cuoco, Frank
    Kutinsky, Ilana
    Aryana, Arash
    Bahnson, Tristram D.
    Lakkireddy, Dhanunjaya
    Woollett, Ian
    Issa, Ziad F.
    Natale, Andrea
    Reddy, Vivek Y.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (12) : 1350 - 1360