共 50 条
Single-sweep pulmonary vein isolation using the new third-generation laser balloon-Evolution in ablation style using endoscopic ablation system
被引:7
|作者:
Tohoku, Shota
[1
]
Bordignon, Stefano
[1
]
Chen, Shaojie
[1
,2
]
Zanchi, Simone
[1
]
Bianchini, Lorenzo
[1
]
Trolese, Luca
[3
]
Operhalski, Felix
[4
]
Urbanek, Lukas
[1
]
Chun, K. R. Julian
[1
,2
]
Schmidt, Boris
[1
,4
]
机构:
[1] Cardioangiol Ctr Bethanien, Wilhelm Epstein Str 4, D-60431 Frankfurt, Germany
[2] Univ Lubeck, Die Sekt Med, Lubeck, Germany
[3] Univ Herzzentrum Freiburg Bad Krozingen, Klin Kardiol & Angiol 1, Freiburg, Germany
[4] Univ Klinikum Frankfurt, Med Klin 3, Klin Kardiol, Frankfurt, Germany
关键词:
atrial fibrillation;
balloon ablation;
endoscopic ablation system;
laser balloon;
pulmonary vein isolation;
RADIOFREQUENCY ABLATION;
CRYOBALLOON;
D O I:
10.1111/jce.15245
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Background The endoscopic ablation system (EAS) is an established ablation device for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). The novel X3 EAS is now equipped with a contiguous circumferential ablation mode (RAPID mode). Aim To determine the feasibility of single-shot fashioned ablation using X3. Methods Consecutive patients who underwent AF ablation using X3 were enrolled. We assessed the acute procedural data focusing on "Single-sweep PVI" defined as successful PVI with a single RAPID mode energy application, and on "first-pass isolation" defined as successful PVI after initial circular lesion set. Results One hundred AF patients (56% male, age: 68 +/- 10 years, 66% paroxysmal AF) were analyzed. A total of 379 of 383 PVs (99%) were isolated with X3. Single-sweep PVI and first-pass-isolation were achieved in 214 PVs (56%) and in 362 PVs (95%), respectively. Single-sweep PVI rates varied across PVs with higher rates at the superior PVs (61.2% vs. inferior PVs: 49.5%, p = .0239) and at PVs with maximal ostial diameter <24 mm (57.6% vs. >24 mm: 36.8%, p = .0151). The mean total procedure and fluoroscopy times were 43.0 +/- 10 and 4.0 +/- 2 min, respectively. In none of the patients an acute thromboembolic event (stroke or transient ischemic attack) or a pericardial effusion/tamponade occurred. A single transient phrenic nerve palsy was observed. Conclusion The new X3 EAS allows for single-shot fashioned ablation in terms of single-sweep PVI in half or more of PVs. The new RAPID ablation mode leads to an improved rate of first-pass isolation associated with very short procedure times without compromising safety.