First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation

被引:214
|
作者
Natale, A
Pisano, E
Shewchik, J
Bash, D
Fanelli, R
Potenza, D
Santarelli, P
Schweikert, R
White, R
Saliba, W
Kanagaratnam, L
Tchou, P
Lesh, M
机构
[1] Cleveland Clin Fdn, Electrophysiol Labs, Cleveland, OH 44195 USA
[2] Casa Sollievo Sofferenza, San Giovanni Rotondo, Italy
[3] Univ Calif San Francisco, San Francisco, CA 94143 USA
关键词
fibrillation; catheters; ultrasonics;
D O I
10.1161/01.CIR.102.16.1879
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Standard mapping and ablation of focal sources of atrial fibrillation are associated with very long procedure times and low efficacy. An anatomic approach to complete pulmonary vein isolation could overcome these limitations. Methods and Results-Fifteen patients with atrial fibrillation refractory to medication underwent circumferential isolation of the pulmonary veins by using a novel catheter, with an ultrasound transducer (8-MHz) mounted near the tip, in a saline-filled balloon. Twelve atrial foci and/or atrial fibrillation triggers were identified in 9 patients (pulmonary vein locations: left upper, 3; right upper, 6; right middle, 1; right lower, 1; and left inferior, 1). In 5 patients, lesions were placed in the absence of any mapped triggers. Irrespective of trigger mapping, circumferential isolation of both upper pulmonary Veins was attempted in all patients. The lower pulmonary veins were ablated when sinus rhythm activation mapping revealed evidence of a sleeve of atrial muscle in the vein. The median number of lesions per patient required to isolate 1 pulmonary vein was 4 (range, 1 to 29). After ablation, no evidence of narrowing was seen with repeat Venography or follow-up computed tomography scan. After a mean follow-up of 35 +/- 6 weeks, 5 patients had recurrence of atrial fibrillation. Three responded to drugs that were previously ineffective, and 2 remained in atrial fibrillation. Conclusions-This novel ultrasound ablation system can successfully isolate multiple pulmonary veins. At early follow-up, this approach seems to be effective in preventing recurrent atrial fibrillation in a significant number of patients.
引用
收藏
页码:1879 / 1882
页数:4
相关论文
共 50 条
  • [1] An anatomic approach to prevention of atrial fibrillation: Pulmonary vein isolation with through-the-balloon ultrasound ablation (TTB-USA)
    Lesh, MD
    Diederich, C
    Guerra, PG
    Goseki, Y
    Sparks, PB
    THORACIC AND CARDIOVASCULAR SURGEON, 1999, 47 : 347 - 351
  • [2] Mechanisms of Recurrent Atrial Arrhythmias After Ablation of Atrial Fibrillation Using Electroanatomic Mapping System and Circumferential Pulmonary Vein Isolation
    Liang, Yanchun
    Wang, Zulu
    Zhao, Ning
    Liang, Ming
    Han, Yaling
    CIRCULATION, 2010, 122 (02) : E24 - E24
  • [3] Circumferential ablation with pulmonary vein isolation in permanent atrial fibrillation
    Cheema, Aamir
    Dong, Jun
    Dalal, Darshan
    Marine, Joseph E.
    Henrikson, Charles A.
    Spragg, David
    Cheng, Alan
    Nazarian, Saman
    Bilchick, Kenneth C.
    Almasry, Ibrahim
    Sinha, Sunil
    Scherr, Daniel
    Halperin, Henry
    Berger, Ronald
    Calkins, Hugh
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (10): : 1425 - 1428
  • [4] Outcome of Circumferential Pulmonary Vein Isolation for Ablation of Atrial Fibrillation: A Single Center Experience
    Chen, Jien-Jiun
    Chiu, Fu-Chun
    Chua, Su-Kiat
    Yu, Chieh-Cheh
    Lin, Lian-Yu
    Tsai, Chia-Ti
    Lai, Ling-Ping
    Lin, Jiunn-Lee
    ACTA CARDIOLOGICA SINICA, 2013, 29 (05) : 457 - 461
  • [5] EARLY EXPERIENCE WITH CIRCUMFERENTIAL PULMONARY VEIN ABLATION FOR ATRIAL FIBRILLATION
    Yan Hao
    Wang Xiang-hai
    Yu You-quan
    Wang Jinfeng
    Liu Wen-jie
    Han Jing-wang
    Cao Heng
    HEART, 2011, 97
  • [6] Efficacy of repeat ablation in patients with recurrent atrial fibrillation after circumferential pulmonary vein isolation
    Pontoppidan, J.
    Nielsen, J. C.
    Poulsen, S. H.
    Jensen, H. K.
    Pedersen, A. K.
    Mortensen, P. T.
    Hansen, P. S.
    EUROPEAN HEART JOURNAL, 2006, 27 : 727 - 727
  • [7] Catheter ablation of focal atrial fibrillation: First experience with ultrasound energy for selective pulmonary vein isolation
    Ernst, SIS
    Loeber, F
    Cappato, R
    Ouyang, FF
    Volkmer, M
    Goya, M
    Vogtmann, T
    Kuck, KH
    CIRCULATION, 2000, 102 (18) : 484 - 485
  • [8] Circumferential pulmonary vein ablation for atrial fibrillation.: The Milan experience
    Pappone, C
    Vicedomini, G
    Augello, G
    Rosanio, S
    CLINICAL CARDIAC PACING AND ELECTROPHYSIOLOGY, 2003, : 23 - 33
  • [9] Pulmonary vein isolation as an end point for left atrial circumferential ablation of atrial fibrillation
    Lemola, K
    Oral, H
    Chugh, A
    Hall, B
    Cheung, P
    Han, J
    Tamirisa, K
    Good, E
    Bogun, F
    Pelosi, F
    Morady, F
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (06) : 1060 - 1066
  • [10] First experience with circumferential pulmonary vein ablation using a laser energy balloon catheter
    Su, WW
    Johnson, SB
    Packer, DL
    CIRCULATION, 2001, 104 (17) : 567 - 567