Bent Laue analyser crystal for Rayleigh-to-Compton computed tomography

被引:1
|
作者
Schulze, C [1 ]
Kleuker, U
机构
[1] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
[2] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
Rayleigh-to-Compton method; computed tomography; conical bending;
D O I
10.1107/S0909049597017251
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new optical system to perform tomography based on the Rayleigh-to-Compton (RC) method with high spatial and spectral resolution is presented. The RC technique allows the effective atomic number of a sample to be measured and finds application in bone mineral densitometry in medicine. It is particularly useful for the characterization of the distribution of biological materials which do not exhibit distinctive diffraction peaks. The system is based on the separation of the elastic line from the spectrum that is scattered by the sample by means of a bent Laue analyser crystal, and the subsequent independent detection of the elastic and inelastic parts of the spectrum with two large-area scintillation counters. The high energy resolution permits operation at low momentum transfer, where the RC method has its best contrast-to-noise ratio for low-Z materials. The geometrical and spectral requirements in terms of the incident beam and the conical analyser crystal are discussed. A first-generation tomographic imaging system (pencil beam, scanned sample) as implemented at the ESRF Compton-Scattering Station ID15B is described. A high-resolution tomographic reconstruction of a bone sample is presented.
引用
收藏
页码:1085 / 1087
页数:3
相关论文
共 50 条
  • [1] A bent Laue analyser crystal for Rayleigh-to-Compton computed tomography
    Swiss Light Source, PSI, CH-5232 Villigen PSI, Switzerland
    不详
    J. Synchrotron Radiat., 3 (1085-1087):
  • [2] A novel approach to the Rayleigh-to-Compton method: Wavelength dispersive tomography.
    Kleuker, U
    Schulze, C
    DEVELOPMENTS IN X-RAY TOMOGRAPHY, 1997, 3149 : 177 - 185
  • [3] A bent Laue-Laue monochromator for a synchrotron-based computed tomography system
    Ren, B
    Dilmanian, FA
    Chapman, LD
    Ivanov, I
    Wu, XY
    Zhong, Z
    Huang, X
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3): : 528 - 550
  • [4] Rayleigh to Compton ratio computed tomography using synchrotron radiation
    Duvauchelle, P
    Peix, G
    Babot, D
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 268 - 278
  • [5] Rayleigh to Compton ratio computed tomography using synchrotron radiation
    Duvauchelle, P
    Peix, G
    Babot, D
    NDT & E INTERNATIONAL, 2000, 33 (01) : 23 - 31
  • [6] A bent Laue-Laue monochromator for a synchrotron-based monochromatic x-ray computed tomography system
    Ren, BR
    MEDICAL PHYSICS, 1998, 25 (12) : 2483 - 2483
  • [7] A BENT LAUE CRYSTAL MONOCHROMATOR FOR ANGIOGRAPHY AT THE NSLS
    SUORTTI, P
    THOMLINSON, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 269 (03): : 639 - 648
  • [8] Bent crystal selection and assembling for the LAUE project
    Liccardo, V.
    Virgilli, E.
    Frontera, F.
    Valsan, V.
    Guidi, V.
    Buffagni, E.
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY VI, 2013, 8861
  • [9] Elastically bent perfect Ge crystal analyser
    Kulda, J
    Mikula, P
    Saroun, J
    PHYSICA B, 2000, 276 : 73 - 74
  • [10] Phase contrast image segmentation using a Laue analyser crystal
    Kitchen, Marcus J.
    Paganin, David M.
    Uesugi, Kentaro
    Allison, Beth J.
    Lewis, Robert A.
    Hooper, Stuart B.
    Pavlov, Konstantin M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (03): : 515 - 534