Bent Laue analyser crystal for Rayleigh-to-Compton computed tomography

被引:1
|
作者
Schulze, C [1 ]
Kleuker, U
机构
[1] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
[2] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
Rayleigh-to-Compton method; computed tomography; conical bending;
D O I
10.1107/S0909049597017251
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new optical system to perform tomography based on the Rayleigh-to-Compton (RC) method with high spatial and spectral resolution is presented. The RC technique allows the effective atomic number of a sample to be measured and finds application in bone mineral densitometry in medicine. It is particularly useful for the characterization of the distribution of biological materials which do not exhibit distinctive diffraction peaks. The system is based on the separation of the elastic line from the spectrum that is scattered by the sample by means of a bent Laue analyser crystal, and the subsequent independent detection of the elastic and inelastic parts of the spectrum with two large-area scintillation counters. The high energy resolution permits operation at low momentum transfer, where the RC method has its best contrast-to-noise ratio for low-Z materials. The geometrical and spectral requirements in terms of the incident beam and the conical analyser crystal are discussed. A first-generation tomographic imaging system (pencil beam, scanned sample) as implemented at the ESRF Compton-Scattering Station ID15B is described. A high-resolution tomographic reconstruction of a bone sample is presented.
引用
收藏
页码:1085 / 1087
页数:3
相关论文
共 50 条
  • [21] Study of the focusing properties of Laue bent crystal by ray-tracing
    Chen Can
    Tong Ya-Jun
    Xie Hong-Lan
    Xiao Ti-Qiao
    ACTA PHYSICA SINICA, 2012, 61 (10)
  • [22] Focusing and Energy Dispersion Properties of a Cylindrically Bent Asymmetric Laue Crystal
    Qi, Peng
    Shi, Xianbo
    Samadi, Nazanin
    Chapman, Dean
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS XIV, 2019, 11108
  • [23] Impact of crystal analyser-based phase contrast X-ray computed tomography on histopathology
    Ichihara, S.
    Sunaguchi, N.
    Ando, M.
    Yuasa, T.
    Shimao, D.
    Kawasaki, T.
    Mori, K.
    Gupta, R.
    VIRCHOWS ARCHIV, 2017, 471 : S61 - S61
  • [24] Characterization of a bent Laue double-crystal beam-expanding monochromator
    Martinson, Mercedes
    Samadi, Nazanin
    Shi, Xianbo
    Liu, Zunping
    Assoufid, Lahsen
    Chapman, Dean
    JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 : 1146 - 1151
  • [25] Tomography using Rayleigh and Compton scattering with digital image reconstruction
    Duvauchelle, P
    Peix, G
    Freud, N
    Babot, D
    JOURNAL DE PHYSIQUE IV, 2000, 10 (P10): : 435 - 448
  • [26] Characterization and on-line adjustment of the sagittal-bent Laue crystal profile
    Dong, Weiwei
    Cai, Quan
    Yang, Fugui
    Liu, Xu
    Yang, Jiaowang
    Diao, Qianshun
    Liu, Peng
    Zhang, Xiaowei
    Hu, Lingfei
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1346 - 1353
  • [27] Experimental verification of dynamical diffraction focusing by a bent crystal wedge in Laue geometry
    Mocella, V.
    Ferrero, C.
    Hrdy, J.
    Wright, J.
    Pascarelli, S.
    Hoszowska, J.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2008, 41 : 695 - 700
  • [28] X-RAY LAUE DIFFRACTION FROM A BENT CRYSTAL - INTEGRATED INTENSITY
    JANACEK, Z
    KUBENA, J
    HOLY, V
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 1978, 50 (01): : 285 - 291
  • [29] Bent Laue crystal monochromator for producing areal x-ray beams
    Zhong, Z
    MEDICAL PHYSICS, 1997, 24 (12) : 2055 - 2055
  • [30] Compton spectroscopy for rotation-mode computed tomography
    Mohammadi, A.
    Baba, M.
    Nakhostin, M.
    Ohuchi, H.
    Abe, M.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2012, 20 (02) : 131 - 140