A bent Laue-Laue monochromator for a synchrotron-based monochromatic x-ray computed tomography system

被引:0
|
作者
Ren, BR [1 ]
机构
[1] Brookhaven Natl Lab, Dept Med, Upton, NY 11973 USA
关键词
BIOMEDICAL RADIOGRAPHY; COMPUTERIZED TOMOGRAPHY; LAUE METHOD; MONOCHROMATORS; NSLS; SILICON; SYNCHROTRON RADIATION; X-RAY DIFFRACTION;
D O I
10.1118/1.598466
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A bent Laue–Laue monochromator for wide, fan-shaped synchrotron x-ray beams was designed and constructed for the program Multiple Energy Computed Tomography (MECT) at the National Synchrotron Light Source (NSLS). MECT uses monochromatic x-ray beams from the NSLS's X17B beamline for CT with improved image contrast-to-noise ratio, image quantification, and the efficacy for dual-energy imaging. The new monochromator uses two Czochralski-grown Si〈111〉 crystals, which are 0.7 and 1.4 mm thick, respectively, and are cut with thick ribs on their upper and lower ends. The crystals are bent cylindrically, using 4-rod benders employing two fixed and two movable rods. The bent-crystal method was needed to solve the difficulties we had with the flat Laue–Laue monochromator previously used in MECT; these included: (a) insufficient beam intensity, (b) excessive beam-intensity fluctuations, and (c) instability of the beam's horizontal profile shape. Compared with flat Laue–Laue monochromator, the bent Laue–Laue device tested at 42 keV and 108 keV showed ∼10-fold increase in the beam flux, ∼5-fold improvement of beam-profile stability, ∼10-fold suppression of beam harmonic contamination at the bending radius of 15 m, and a smaller energy bandwidth at certain bending radii. The new monochromator should reduce MECT's image noise and artifacts, bringing its performance close to that of the ideal CT. © 1998, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2483 / 2483
页数:1
相关论文
共 50 条
  • [1] A bent Laue-Laue monochromator for a synchrotron-based computed tomography system
    Ren, B
    Dilmanian, FA
    Chapman, LD
    Ivanov, I
    Wu, XY
    Zhong, Z
    Huang, X
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3): : 528 - 550
  • [2] Ultrasound adjustable Laue-Laue double-crystal x-ray monochromator
    Polikarpov, I
    Panov, VV
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (16) : 2083 - 2086
  • [3] Bent Laue crystal monochromator for producing areal x-ray beams
    Zhong, Z
    MEDICAL PHYSICS, 1997, 24 (12) : 2055 - 2055
  • [4] Hard X-ray Laue monochromator
    Kocharyan, V. R.
    Gogolev, A. S.
    Kiziridi, A. A.
    Batranin, A. V.
    Muradyan, T. R.
    VIII INTERNATIONAL SCIENTIFIC CONFERENCE - ISSUES OF PHYSICS AND TECHNOLOGY IN SCIENCE, INDUSTRY AND MEDICINE, 2016, 135
  • [5] Research on a logarithmically bent Laue crystal analyzer for X-ray monochromatic backlight imaging
    Wu, Yufen
    Xiao, Shali
    Lu, Jian
    Liu, Lifeng
    Yang, Qingguo
    Huang, Xianbin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (07):
  • [6] Double Laue-crystal monochromator for an X-ray imaging beamline with synchrotron radiation
    Hu Wen
    Xie Hong-Lan
    Du Guo-Hao
    Xiao Ti-Qiao
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2007, 31 (06): : 597 - 601
  • [7] X-ray topography of perfect crystals using the Laue-Laue three-beam case of diffraction
    Heyroth, F
    Eisenschmidt, C
    Hoche, HR
    CRYSTAL RESEARCH AND TECHNOLOGY, 1998, 33 (04) : 547 - 554
  • [8] Synchrotron x-ray study of multilayers in Laue geometry
    Kang, HC
    Stephenson, GB
    Liu, C
    Conley, R
    Macrander, AT
    Maser, J
    Bajt, S
    Chapman, HN
    X-RAY SOURCES AND OPTICS, 2004, 5537 : 127 - 132
  • [9] Simulation of bent Laue crystals for a high-energy X-ray monochromator with heat load consideration
    Wang, Jiayi
    Gao, Lidan
    Li, Ming
    Yang, Yiming
    Li, Yanchun
    Cheng, Hu
    Fan, Longlong
    Wang, Youkang
    Guo, Huilong
    Jia, Quanjie
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2025, 58 : 154 - 167
  • [10] Incoherent scatter computed tomography with monochromatic synchrotron x-ray
    Yuasa, T
    Takeda, T
    Akiba, M
    Kazama, M
    Hoshino, A
    Watanabe, Y
    Hyodo, K
    Dilmanian, FA
    Akatsuka, T
    Itai, Y
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 728 - 729