A bent Laue-Laue monochromator for a synchrotron-based monochromatic x-ray computed tomography system

被引:0
|
作者
Ren, BR [1 ]
机构
[1] Brookhaven Natl Lab, Dept Med, Upton, NY 11973 USA
关键词
BIOMEDICAL RADIOGRAPHY; COMPUTERIZED TOMOGRAPHY; LAUE METHOD; MONOCHROMATORS; NSLS; SILICON; SYNCHROTRON RADIATION; X-RAY DIFFRACTION;
D O I
10.1118/1.598466
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A bent Laue–Laue monochromator for wide, fan-shaped synchrotron x-ray beams was designed and constructed for the program Multiple Energy Computed Tomography (MECT) at the National Synchrotron Light Source (NSLS). MECT uses monochromatic x-ray beams from the NSLS's X17B beamline for CT with improved image contrast-to-noise ratio, image quantification, and the efficacy for dual-energy imaging. The new monochromator uses two Czochralski-grown Si〈111〉 crystals, which are 0.7 and 1.4 mm thick, respectively, and are cut with thick ribs on their upper and lower ends. The crystals are bent cylindrically, using 4-rod benders employing two fixed and two movable rods. The bent-crystal method was needed to solve the difficulties we had with the flat Laue–Laue monochromator previously used in MECT; these included: (a) insufficient beam intensity, (b) excessive beam-intensity fluctuations, and (c) instability of the beam's horizontal profile shape. Compared with flat Laue–Laue monochromator, the bent Laue–Laue device tested at 42 keV and 108 keV showed ∼10-fold increase in the beam flux, ∼5-fold improvement of beam-profile stability, ∼10-fold suppression of beam harmonic contamination at the bending radius of 15 m, and a smaller energy bandwidth at certain bending radii. The new monochromator should reduce MECT's image noise and artifacts, bringing its performance close to that of the ideal CT. © 1998, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2483 / 2483
页数:1
相关论文
共 50 条
  • [31] Conditions for reception of x-ray monochromatic bunches of the maximum intensity in geometry Laue.
    Margaryan, V. V.
    Hayrapetyan, K. T.
    Noreyan, S. N.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2010, 66 : S303 - S303
  • [32] COMPUTER DECIPHERING OF LAUE PATTERNS - APPLICATION TO WHITE SYNCHROTRON X-RAY TOPOGRAPHY
    SHEREMETYEV, IA
    TURBAL, AV
    LITVINOV, YM
    MIKHAILOV, MA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 308 (1-2): : 451 - 455
  • [33] Quantitative performance measurements of bent crystal Laue analyzers for X-ray fluorescence spectroscopy
    Karanfil, C.
    Bunker, G.
    Newville, M.
    Segre, C. U.
    Chapman, D.
    JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 : 375 - 380
  • [34] Three-dimensional monochromatic x-ray computed tomography using synchrotron radiation
    Saito, T
    Kudo, H
    Takeda, T
    Itai, Y
    Tokumori, K
    Toyofuku, F
    Hyodo, K
    Ando, M
    Nishimura, K
    Uyama, C
    OPTICAL ENGINEERING, 1998, 37 (08) : 2258 - 2268
  • [35] Diffuse scattering at the laue X-ray diffraction in toroidally bent single crystals with microdefects
    Olikhovskii, S. J.
    Molodkin, V. B.
    Nizkova, A. I.
    Kononenko, O. S.
    Katasonov, A. A.
    METALLOFIZIKA I NOVEISHIE TEKHNOLOGII, 2007, 29 (10): : 1333 - 1345
  • [36] GENERAL DYNAMICAL THEORY OF X-RAY LAUE DIFFRACTION FROM A HOMOGENEOUSLY BENT CRYSTAL
    CHUKHOVSKII, FN
    PETRASHEN, PV
    ACTA CRYSTALLOGRAPHICA SECTION A, 1977, 33 (MAR1): : 311 - 319
  • [37] Energy-dispersive X-ray micro Laue diffraction on a bent gold nanowire
    AlHassan, Ali
    Abboud, A.
    Cornelius, T. W.
    Ren, Z.
    Thomas, O.
    Richter, G.
    Micha, J-S
    Send, S.
    Hartmann, R.
    Struder, L.
    Pietsch, U.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2021, 54 : 80 - 86
  • [38] Bent Laue X-ray Fluorescence Imaging of Manganese in Biological Tissues - Preliminary Results\
    Zhu, Ying
    Bewer, Brian
    Zhang, Honglin
    Nichol, Helen
    Thomlinson, Bill
    Chapman, Dean
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 457 - +
  • [39] Preparation and measurement of an x-ray Laue-type monochromator based on a WSi2/Si multilayer
    Yue, Shuaipeng
    Hou, Qingyan
    Ji, Bin
    Zhou, Liang
    Li, Ming
    Liu, Peng
    Chang, Guangcai
    APPLIED OPTICS, 2024, 63 (12) : 3260 - 3264
  • [40] SIMULATION OF X-RAY TRAVERSE TOPOGRAPHS AND SYNCHROTRON LAUE TOPOGRAPHS - APPLICATION OF THE RECIPROCITY THEOREM
    CARVALHO, CAM
    EPELBOIN, Y
    ACTA CRYSTALLOGRAPHICA SECTION A, 1993, 49 : 467 - 473