Quantitative performance measurements of bent crystal Laue analyzers for X-ray fluorescence spectroscopy

被引:8
|
作者
Karanfil, C. [1 ]
Bunker, G. [2 ,3 ,4 ]
Newville, M. [5 ]
Segre, C. U. [2 ,3 ]
Chapman, D. [6 ]
机构
[1] Univ Mugla, Fac Sci, Dept Phys, TR-48187 Kotekli Mugla, Turkey
[2] IIT, Ctr Synchrotron Radiat Res & Instrumentat, Chicago, IL 60616 USA
[3] IIT, Dept Phys, Chicago, IL 60616 USA
[4] Quercus Xray Technol LLC, Oak Pk, IL 60304 USA
[5] Univ Chicago, Consortium Adv Radiat Sources, Chicago, IL 60637 USA
[6] Univ Saskatchewan, Dept Anat & Cell Biol, Saskatoon, SK S7N 5E5, Canada
基金
美国国家科学基金会;
关键词
X-ray optics; X-ray fluorescence; X-ray spectroscopy; XAFS; bent crystal analyzer; X-ray filters; ABSORPTION SPECTROSCOPY; SILICON CRYSTAL; GEOMETRY; BRAGG;
D O I
10.1107/S0909049512003937
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Third-generation synchrotron radiation sources pose difficult challenges for energy-dispersive detectors for XAFS because of their count rate limitations. One solution to this problem is the bent crystal Laue analyzer (BCLA), which removes most of the undesired scatter and fluorescence before it reaches the detector, effectively eliminating detector saturation due to background. In this paper experimental measurements of BCLA performance in conjunction with a 13-element germanium detector, and a quantitative analysis of the signal-to-noise improvement of BCLAs are presented. The performance of BCLAs are compared with filters and slits.
引用
收藏
页码:375 / 380
页数:6
相关论文
共 50 条
  • [1] Bent silicon crystal in the Laue geometry to resolve x-ray fluorescence for x-ray absorption spectroscopy
    Kropf, AJ
    Finch, RJ
    Fortner, JA
    Aase, S
    Karanfil, C
    Segre, CU
    Terry, J
    Bunker, G
    Chapman, LD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (11): : 4696 - 4702
  • [2] A bent silicon crystal in the Laue geometry to resolve actinide x-ray fluorescence for x-ray absorption spectroscopy
    Kropf, A. J.
    Fortner, J. A.
    Finch, R. J.
    Cunnane, J. C.
    Karanfil, C.
    PHYSICA SCRIPTA, 2005, T115 : 998 - 1000
  • [3] Cylindrically bent Laue analyzer in an X-ray Raman/emission spectrometer: performance tests and a comparison with spherically bent Bragg analyzers
    Hiraoka, Nozomu
    JOURNAL OF SYNCHROTRON RADIATION, 2025, 32 : 109 - 117
  • [4] Vacuum formed temporary spherically and toroidally bent crystal analyzers for x-ray absorption and x-ray emission spectroscopy
    Jahrman, Evan P.
    Holden, William M.
    Ditter, Alexander S.
    Kozimor, Stosh A.
    Kihara, Scott L.
    Seidler, Gerald T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (01):
  • [5] X-RAY LAUE DIFFRACTION FROM A BENT CRYSTAL - INTEGRATED INTENSITY
    JANACEK, Z
    KUBENA, J
    HOLY, V
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 1978, 50 (01): : 285 - 291
  • [6] Bent Laue crystal monochromator for producing areal x-ray beams
    Zhong, Z
    MEDICAL PHYSICS, 1997, 24 (12) : 2055 - 2055
  • [7] 'Smoothing' of deformation in the case of X-ray asymmetrical Laue diffraction in bent crystal
    Molodkin, VB
    Shevchenko, MB
    Pobydaylo, OV
    METALLOFIZIKA I NOVEISHIE TEKHNOLOGII, 2002, 24 (04): : 553 - 557
  • [8] BENT CRYSTAL SPECTROMETER FOR SOLAR X-RAY SPECTROSCOPY
    RAPLEY, CG
    CULHANE, JL
    ACTON, LW
    CATURA, RC
    JOKI, EG
    BAKKE, JC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (09): : 1123 - 1130
  • [9] Spherically bent mica analyzers as universal dispersing elements for X-ray spectroscopy
    Joseph, Emily S.
    Jahrman, Evan P.
    Seidler, Gerald T.
    X-RAY SPECTROMETRY, 2020, 49 (04) : 493 - 501
  • [10] Bent Laue X-ray Fluorescence Imaging of Manganese in Biological Tissues - Preliminary Results\
    Zhu, Ying
    Bewer, Brian
    Zhang, Honglin
    Nichol, Helen
    Thomlinson, Bill
    Chapman, Dean
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 457 - +