K-edge subtraction imaging for angiography at a compact synchrotron source

被引:0
|
作者
Kulpe, Stephanie [1 ,2 ]
Dierolf, Martin [1 ,2 ]
Braig, Eva-Maria [1 ,2 ]
Guenther, Benedikt [1 ,2 ]
Achterhold, Klaus [1 ,2 ]
Gleich, Bernhard [2 ]
Herzen, Julia [1 ,2 ]
Rummeny, Ernst [3 ,4 ]
Pfeiffer, Franz [1 ,2 ,3 ,4 ]
Pfeiffer, Daniela [3 ,4 ]
机构
[1] Tech Univ Munich, Dept Phys, Chair Biomed Phys, James Franck Str 1, D-85748 Garching, Germany
[2] Tech Univ Munich, Munich Sch BioEngn, Boltzmannstr 11, D-85748 Garching, Germany
[3] Munich Sch Med, Dept Diagnost & Intervent Radiol, Ismaniger Str 22, D-81675 Munich, Germany
[4] Klinikum Rechts Der Isar, Ismaniger Str 22, D-81675 Munich, Germany
来源
ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS VII | 2019年 / 11110卷
关键词
K-edge subtraction imaging; angiography; iodine; radiography; biomedical imaging; brilliant X-ray source; GADOLINIUM-BASED CONTRAST; CORONARY-ANGIOGRAPHY; RADIATION;
D O I
10.1117/12.2526771
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
About one third of all deaths worldwide can be traced back to some form of cardiovascular disease. The gold standard for the diagnosis and interventional treatment of blood vessels is digital subtraction angiography (DSA). An alternative to DSA is K-edge subtraction (KES) imaging, which has been shown to be advantageous for moving organs and to eliminate image artifacts caused by patient movement. As highly brilliant, monochromatic X-rays are required for this method, it has been limited to synchrotron facilities so far, restraining the applicability in clinical routine. Over the past decades, compact synchrotron X-ray sources based on inverse Compton scattering have been evolving, which provide X-rays with sufficient brilliance and that meet spatial and financial requirements affordable in laboratory settings or for university hospitals. In this study, we demonstrate a proof-of-principle KES imaging experiment using the Munich Compact Light Source (MuCLS), the first user-dedicated installation of a compact synchrotron X-ray source worldwide. It is shown that the proposed filter-based KES method allows for iodine-contrast agent and calcium to be clearly separated, thereby providing X-ray images only showing one of the two materials. The results show that the quasi-monochromatic spectrum of the MuCLS enables filter-based K-edge subtraction imaging and can become an important tool in pre-clinical research and possible future clinical diagnostics.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Field flatteners fabricated with a rapid prototyper for K-edge subtraction imaging of small animals
    Zhu, Ying
    Zhang, Honglin
    Bewer, Brian
    Popescu, Bogdan Florin Gh.
    Nichol, Helen
    Chapman, Dean
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 588 (03): : 442 - 447
  • [42] Imaging dynamic lung strain and specific elastance by K-edge subtraction computed tomography
    Porra, Liisa
    Albu, Gergely
    Broche, Ludovic
    Degrugilliers, Loic
    Wallin, Matts
    Halback, Magnus
    Petak, Ferenc
    Habre, Walid
    Bayat, Sam
    ACTA PHYSIOLOGICA, 2016, 217 : 137 - 137
  • [43] High-resolution in-vivo synchrotron imaging of lung structure and regional ventilation in rat using the K-edge subtraction technique
    Porra, L.
    Layachi, S.
    Sovijaervi, R.
    Suortti, P.
    Bayat, S.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2010, 24 : 103 - 103
  • [44] Three dimensional mapping of strontium in bone by dual energy K-edge subtraction imaging
    Cooper, D. M. L.
    Chapman, L. D.
    Carter, Y.
    Wu, Y.
    Panahifar, A.
    Britz, H. M.
    Bewer, B.
    Zhouping, W.
    Duke, M. J. M.
    Doschak, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (18): : 5777 - 5786
  • [45] XENON K-EDGE DICHROMOGRAPHIC BRONCHOGRAPHY - SYNCHROTRON-RADIATION BASED MEDICAL IMAGING
    RUBENSTEIN, E
    GIACOMINI, JC
    GORDON, HJ
    RUBENSTEIN, JAL
    BROWN, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 364 (02): : 360 - 361
  • [46] Imaging Regional Lung Structure and Function in Small Animals Using Synchrotron Radiation Phase-Contrast and K-Edge Subtraction Computed Tomography
    Bayat, Sam
    Fardin, Luca
    Cercos-Pita, Jose Luis
    Perchiazzi, Gaetano
    Bravin, Alberto
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [47] SYNCHROTRON-RADIATION CINE K-EDGE ENERGY SUBTRACTION CORONARY ARTERIOGRAPHY USING AN IODINE FILTER METHOD
    TAKEDA, T
    ITAI, Y
    YOSHIOKA, H
    UMETANI, K
    UEDA, K
    AKISADA, M
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (04) : 462 - 468
  • [48] Spectral K-edge subtraction imaging of experimental non-radioactive barium uptake in bone
    Panahifar, Arash
    Samadi, Nazanin
    Swanston, Treena M.
    Chapman, L. Dean
    Cooper, David M. L.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12): : 1765 - 1770
  • [49] X-ray K-edge subtraction television system
    Suwa, Akio
    Fukagawa, Hiroshi
    Suzuki, Kiwamu
    Hasegawa, Shin
    Ando, Masami
    Hyodo, Kazuyuki
    Akisada, Masayoshi
    Nishimura, Katsuyuki
    Konishi, Keisuke
    Toyofuku, Fukae
    Takenaka, Eiichi
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1988, 27 (10): : 1989 - 1996
  • [50] Simultaneous Acquisition of K-Edge Subtraction Images using a pnCCD
    Nurdan, K.
    Nurdan, T. Conka
    AlTaani, M.
    Yousef, H.
    Walenta, A. H.
    Walenta, K.
    Abboud, A.
    Nasr, A.
    Ruebsamen, O.
    Schenk, W.
    Pietsch, U.
    Send, S.
    Hartmann, R.
    Leitenberger, W.
    Strueder, L.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3240 - +