K-edge subtraction imaging for angiography at a compact synchrotron source

被引:0
|
作者
Kulpe, Stephanie [1 ,2 ]
Dierolf, Martin [1 ,2 ]
Braig, Eva-Maria [1 ,2 ]
Guenther, Benedikt [1 ,2 ]
Achterhold, Klaus [1 ,2 ]
Gleich, Bernhard [2 ]
Herzen, Julia [1 ,2 ]
Rummeny, Ernst [3 ,4 ]
Pfeiffer, Franz [1 ,2 ,3 ,4 ]
Pfeiffer, Daniela [3 ,4 ]
机构
[1] Tech Univ Munich, Dept Phys, Chair Biomed Phys, James Franck Str 1, D-85748 Garching, Germany
[2] Tech Univ Munich, Munich Sch BioEngn, Boltzmannstr 11, D-85748 Garching, Germany
[3] Munich Sch Med, Dept Diagnost & Intervent Radiol, Ismaniger Str 22, D-81675 Munich, Germany
[4] Klinikum Rechts Der Isar, Ismaniger Str 22, D-81675 Munich, Germany
来源
ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS VII | 2019年 / 11110卷
关键词
K-edge subtraction imaging; angiography; iodine; radiography; biomedical imaging; brilliant X-ray source; GADOLINIUM-BASED CONTRAST; CORONARY-ANGIOGRAPHY; RADIATION;
D O I
10.1117/12.2526771
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
About one third of all deaths worldwide can be traced back to some form of cardiovascular disease. The gold standard for the diagnosis and interventional treatment of blood vessels is digital subtraction angiography (DSA). An alternative to DSA is K-edge subtraction (KES) imaging, which has been shown to be advantageous for moving organs and to eliminate image artifacts caused by patient movement. As highly brilliant, monochromatic X-rays are required for this method, it has been limited to synchrotron facilities so far, restraining the applicability in clinical routine. Over the past decades, compact synchrotron X-ray sources based on inverse Compton scattering have been evolving, which provide X-rays with sufficient brilliance and that meet spatial and financial requirements affordable in laboratory settings or for university hospitals. In this study, we demonstrate a proof-of-principle KES imaging experiment using the Munich Compact Light Source (MuCLS), the first user-dedicated installation of a compact synchrotron X-ray source worldwide. It is shown that the proposed filter-based KES method allows for iodine-contrast agent and calcium to be clearly separated, thereby providing X-ray images only showing one of the two materials. The results show that the quasi-monochromatic spectrum of the MuCLS enables filter-based K-edge subtraction imaging and can become an important tool in pre-clinical research and possible future clinical diagnostics.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Visualization of pigment distributions in paintings using synchrotron K-edge imaging
    Krug, K
    Dik, J
    den Leeuw, M
    Whitson, A
    Tortora, J
    Coan, P
    Nemoz, C
    Bravin, A
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2006, 83 (02): : 247 - 251
  • [32] Quantitative analysis of the effect of energy separation in k-edge digital subtraction imaging
    Sarnelli, A.
    Taibi, A.
    Baldelli, P.
    Gambaccini, M.
    Bravin, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (11): : 3015 - 3026
  • [33] Effect of moderate PEEP on regional ventilation distribution during severe bronchoconstriction in rabbit studied by K-edge subtraction synchrotron imaging
    Porra, L.
    Suhonen, H.
    Suortti, P.
    Sovijarvi, A.
    Bayat, S.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2012, 26 : 31 - 31
  • [34] K-edge subtraction imaging using a pixellated energy-resolving detector
    Pani, Silvia
    Saifuddin, Sarene C.
    Christodoulou, Christiana
    Veale, Matthew
    Seller, Paul
    Speller, Robert D.
    Wilson, Matthew
    Scuffham, James W.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [35] REAL-TIME K-EDGE SUBTRACTION X-RAY-IMAGING
    FUKAGAWA, H
    NODA, C
    SUZUKI, Y
    HASEGAWA, S
    ANDO, M
    HYODO, K
    NISHIMURA, K
    AKISADA, M
    TAKENAKA, E
    HOSAKA, R
    TOYOFUKU, F
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2268 - 2271
  • [36] Feasibility of K-edge subtraction (KES) synchrotron imaging for the measurement of regional aerosol deposition, lung ventilation and airway morphology in rabbit
    Degrugilliers, L.
    Porra, L.
    Albu, G.
    Suhonen, H.
    Strengell, S.
    Fodor, G.
    Petak, F.
    Suortti, P.
    Habre, W.
    Sovijarvi, A.
    Bayat, S.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2012, 26 : 58 - 58
  • [37] Dual-energy digital subtraction angiography using characteristic radiation and K-edge filtration
    Richardson, JM
    Petr, R
    Theophanis, S
    Chapman, LD
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1545 - 1546
  • [38] Crossover artifact in X-ray focusing imaging systems: K-edge subtraction imaging
    Bassey, B.
    Samadi, N.
    Panahifar, A.
    Cooper, D. M. L.
    Chapman, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 910 : 26 - 34
  • [40] High-resolution in-vivo synchrotron imaging of lung structure and regional ventilation in rat using the K-edge subtraction technique
    Porra, L.
    Layachi, S.
    Sovijarvi, A. R. A.
    Suortti, P.
    Bayat, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181