K-edge subtraction imaging for angiography at a compact synchrotron source

被引:0
|
作者
Kulpe, Stephanie [1 ,2 ]
Dierolf, Martin [1 ,2 ]
Braig, Eva-Maria [1 ,2 ]
Guenther, Benedikt [1 ,2 ]
Achterhold, Klaus [1 ,2 ]
Gleich, Bernhard [2 ]
Herzen, Julia [1 ,2 ]
Rummeny, Ernst [3 ,4 ]
Pfeiffer, Franz [1 ,2 ,3 ,4 ]
Pfeiffer, Daniela [3 ,4 ]
机构
[1] Tech Univ Munich, Dept Phys, Chair Biomed Phys, James Franck Str 1, D-85748 Garching, Germany
[2] Tech Univ Munich, Munich Sch BioEngn, Boltzmannstr 11, D-85748 Garching, Germany
[3] Munich Sch Med, Dept Diagnost & Intervent Radiol, Ismaniger Str 22, D-81675 Munich, Germany
[4] Klinikum Rechts Der Isar, Ismaniger Str 22, D-81675 Munich, Germany
来源
ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS VII | 2019年 / 11110卷
关键词
K-edge subtraction imaging; angiography; iodine; radiography; biomedical imaging; brilliant X-ray source; GADOLINIUM-BASED CONTRAST; CORONARY-ANGIOGRAPHY; RADIATION;
D O I
10.1117/12.2526771
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
About one third of all deaths worldwide can be traced back to some form of cardiovascular disease. The gold standard for the diagnosis and interventional treatment of blood vessels is digital subtraction angiography (DSA). An alternative to DSA is K-edge subtraction (KES) imaging, which has been shown to be advantageous for moving organs and to eliminate image artifacts caused by patient movement. As highly brilliant, monochromatic X-rays are required for this method, it has been limited to synchrotron facilities so far, restraining the applicability in clinical routine. Over the past decades, compact synchrotron X-ray sources based on inverse Compton scattering have been evolving, which provide X-rays with sufficient brilliance and that meet spatial and financial requirements affordable in laboratory settings or for university hospitals. In this study, we demonstrate a proof-of-principle KES imaging experiment using the Munich Compact Light Source (MuCLS), the first user-dedicated installation of a compact synchrotron X-ray source worldwide. It is shown that the proposed filter-based KES method allows for iodine-contrast agent and calcium to be clearly separated, thereby providing X-ray images only showing one of the two materials. The results show that the quasi-monochromatic spectrum of the MuCLS enables filter-based K-edge subtraction imaging and can become an important tool in pre-clinical research and possible future clinical diagnostics.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Synchrotron-based intra-venous K-edge digital subtraction angiography in a pig model: A feasibility study
    Schueltke, Elisabeth
    Fiedler, Stefan
    Nemoz, Christian
    Ogieglo, Lissa
    Kelly, Michael E.
    Crawford, Paul
    Esteve, Francois
    Brochard, Thierry
    Renier, Michel
    Requardt, Herwig
    Le Duc, Geraldine
    Juurlink, Bernhard
    Meguro, Kotoo
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 73 (03) : 677 - 681
  • [22] TRANSVENOUS CORONARY ANGIOGRAPHY USING SYNCHROTRON RADIATION AND K-EDGE DICHROMOGRAPHY
    GIACOMINI, JC
    GORDON, HJ
    THOMPSON, AC
    ZEMAN, HD
    HOFSTADTER, R
    BROWN, GS
    THOMLINSON, W
    RUBENSTEIN, E
    CLINICAL RESEARCH, 1991, 39 (02): : A201 - A201
  • [23] Fractal dimension of pulmonary gas and blood distribution assessed by synchrotron K-edge subtraction imaging: effect of bronchoconstriction
    Bayat, Sam
    Degrugilliers, Loic
    Porra, Liisa
    Strengell, Satu
    Petak, Ferenc
    Habre, Walid
    JOURNAL OF APPLIED PHYSIOLOGY, 2023, 134 (04) : 995 - 1003
  • [24] DIGITAL K-EDGE SUBTRACTION RADIOGRAPHY
    KRUGER, RA
    MISTRETTA, CA
    CRUMMY, AB
    SACKETT, JF
    GOODSITT, MM
    RIEDERER, SJ
    HOUK, TL
    SHAW, CG
    FLEMING, D
    RADIOLOGY, 1977, 125 (01) : 243 - 245
  • [25] SR CINE K-EDGE SUBTRACTION ANGIOGRAPHY OF THE RABBIT CORONARY-ARTERIES
    TAKEDA, T
    AKISADA, M
    ANNO, I
    NAKAJIMA, T
    UEDA, K
    UMETANI, K
    YAMAGUCHI, C
    JOURNAL OF CARDIOVASCULAR TECHNOLOGY, 1990, 9 (03): : 203 - 211
  • [26] Development of a combined K-edge subtraction and fluorescence subtraction imaging system for small animals
    Bewer, Brian
    Zhang, Honglin
    Zhu, Ying
    Zhang, Limei
    George, Graham N.
    Pickering, Ingrid J.
    Chapman, Dean
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (08):
  • [27] SR HIGH-SPEED K-EDGE SUBTRACTION ANGIOGRAPHY IN THE SMALL ANIMAL
    TAKEDA, T
    AKISADA, M
    NAKAJIMA, T
    ANNO, I
    UEDA, K
    UMETANI, K
    YAMAGUCHI, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2329 - 2329
  • [28] Optimization of K-Edge Subtraction Imaging Using a Pixellated Spectroscopic Detector
    Pani, Silvia
    Saifuddin, Sarene C.
    Ferreira, Filipa I. M.
    Scuffham, James W.
    Stratmann, Philipp
    Wilson, Matthew D.
    Veale, Matthew C.
    Bell, Steven
    Seller, Paul
    Sellin, Paul J.
    Cernik, Robert J.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3063 - 3066
  • [29] Three-dimensional labeling of newly formed bone using synchrotron radiation barium K-edge subtraction imaging
    Panahifar, Arash
    Swanston, Treena M.
    Pushie, M. Jake
    Belev, George
    Chapman, Dean
    Weber, Lynn
    Cooper, David M. L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (13): : 5077 - 5088
  • [30] Visualization of pigment distributions in paintings using synchrotron K-edge imaging
    K. Krug
    J. Dik
    M. den Leeuw
    A. Whitson
    J. Tortora
    P. Coan
    C. Nemoz
    A. Bravin
    Applied Physics A, 2006, 83 : 247 - 251