K-edge subtraction imaging for angiography at a compact synchrotron source

被引:0
|
作者
Kulpe, Stephanie [1 ,2 ]
Dierolf, Martin [1 ,2 ]
Braig, Eva-Maria [1 ,2 ]
Guenther, Benedikt [1 ,2 ]
Achterhold, Klaus [1 ,2 ]
Gleich, Bernhard [2 ]
Herzen, Julia [1 ,2 ]
Rummeny, Ernst [3 ,4 ]
Pfeiffer, Franz [1 ,2 ,3 ,4 ]
Pfeiffer, Daniela [3 ,4 ]
机构
[1] Tech Univ Munich, Dept Phys, Chair Biomed Phys, James Franck Str 1, D-85748 Garching, Germany
[2] Tech Univ Munich, Munich Sch BioEngn, Boltzmannstr 11, D-85748 Garching, Germany
[3] Munich Sch Med, Dept Diagnost & Intervent Radiol, Ismaniger Str 22, D-81675 Munich, Germany
[4] Klinikum Rechts Der Isar, Ismaniger Str 22, D-81675 Munich, Germany
来源
ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS VII | 2019年 / 11110卷
关键词
K-edge subtraction imaging; angiography; iodine; radiography; biomedical imaging; brilliant X-ray source; GADOLINIUM-BASED CONTRAST; CORONARY-ANGIOGRAPHY; RADIATION;
D O I
10.1117/12.2526771
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
About one third of all deaths worldwide can be traced back to some form of cardiovascular disease. The gold standard for the diagnosis and interventional treatment of blood vessels is digital subtraction angiography (DSA). An alternative to DSA is K-edge subtraction (KES) imaging, which has been shown to be advantageous for moving organs and to eliminate image artifacts caused by patient movement. As highly brilliant, monochromatic X-rays are required for this method, it has been limited to synchrotron facilities so far, restraining the applicability in clinical routine. Over the past decades, compact synchrotron X-ray sources based on inverse Compton scattering have been evolving, which provide X-rays with sufficient brilliance and that meet spatial and financial requirements affordable in laboratory settings or for university hospitals. In this study, we demonstrate a proof-of-principle KES imaging experiment using the Munich Compact Light Source (MuCLS), the first user-dedicated installation of a compact synchrotron X-ray source worldwide. It is shown that the proposed filter-based KES method allows for iodine-contrast agent and calcium to be clearly separated, thereby providing X-ray images only showing one of the two materials. The results show that the quasi-monochromatic spectrum of the MuCLS enables filter-based K-edge subtraction imaging and can become an important tool in pre-clinical research and possible future clinical diagnostics.
引用
收藏
页数:12
相关论文
共 50 条
  • [11] Dynamic K-edge Subtraction Fluoroscopy at a Compact Inverse-Compton Synchrotron X-ray Source
    Stephanie Kulpe
    Martin Dierolf
    Benedikt Günther
    Johannes Brantl
    Madleen Busse
    Klaus Achterhold
    Bernhard Gleich
    Franz Pfeiffer
    Daniela Pfeiffer
    Scientific Reports, 10
  • [12] Spectral K-edge subtraction imaging
    Zhu, Y.
    Samadi, N.
    Martinson, M.
    Bassey, B.
    Wei, Z.
    Belev, G.
    Chapman, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (10): : 2485 - 2503
  • [13] K-edge Subtraction Computed Tomography with a Compact Synchrotron X-ray Source (vol 9, 1332, 2019)
    Kulpe, Stephanie
    Dierolf, Martin
    Guenther, Benedikt
    Busse, Madleen
    Achterhold, Klaus
    Gleich, Bernhard
    Herzen, Julia
    Rummeny, Ernst
    Pfeiffer, Franz
    Pfeiffer, Daniela
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [14] IODINE K-EDGE DUAL-ENERGY IMAGING FOR SUBTRACTION ANGIOGRAPHY USING SYNCHROTRON RADIATION AND A 2-DIMENSIONAL DETECTOR
    UMETANI, K
    UEDA, K
    TAKEDA, T
    AKISADA, M
    NAKAJIMA, T
    ANNO, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 301 (03): : 579 - 588
  • [15] In vivo K-edge imaging with synchrotron radiation
    Elleaume, H
    Charvet, AM
    Le Duc, G
    Estève, F
    Bertrand, B
    Corde, S
    Farion, R
    Lefaix, JL
    Leplat, JJ
    Berkvens, P
    Berruyer, G
    Brochard, T
    Dabin, Y
    Draperi, A
    Fiedler, S
    Nemoz, C
    Perez, M
    Renier, M
    Suortti, P
    Thomlinson, W
    Le Bas, JF
    CELLULAR AND MOLECULAR BIOLOGY, 2000, 46 (06) : 1065 - 1075
  • [16] K-edge subtraction synchrotron X-ray imaging in bio-medical research
    Thomlinson, W.
    Elleaume, H.
    Porra, L.
    Suortti, P.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 49 : 58 - 76
  • [17] Inverse Compton radiation: a novel x-ray source for K-edge subtraction angiography?
    Paterno, G.
    Cardarelli, P.
    Gambaccini, M.
    Serafini, L.
    Petrillo, V
    Drebot, I
    Taibi, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (18):
  • [18] The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography
    Schültke, E
    Fiedler, S
    Kelly, M
    Griebel, R
    Juurlink, B
    LeDuc, G
    Estève, F
    Le Bas, JF
    Renier, M
    Nemoz, C
    Meguro, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2): : 84 - 87
  • [19] ANIMAL-EXPERIMENTS BY K-EDGE SUBTRACTION ANGIOGRAPHY BY USING SR
    ANNO, I
    AKISADA, M
    TAKEDA, T
    SUGISHITA, Y
    KAKIHANA, M
    OHTSUKA, S
    NISHIMURA, K
    HASEGAWA, S
    TAKENAKA, E
    HYODO, K
    ANDO, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2330 - 2331
  • [20] Comparison of iodine K-edge subtraction and fluorescence subtraction imaging in an animal system
    Zhang, H.
    Zhu, Y.
    Bewer, B.
    Zhang, L.
    Korbas, M.
    Pickering, I. J.
    George, G. N.
    Gupta, M.
    Chapman, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 594 (02): : 283 - 291