Statistical reconstruction of x-ray CT images from energy-integrated signals: A simulation study

被引:0
|
作者
Lasio, G
Whiting, B
Williamson, J
机构
[1] Virginia Commonwealth Univ, Richmond, VA 23284 USA
[2] Mallinckrodt Inst Radiol, St Louis, MO USA
关键词
D O I
10.1118/1.1998252
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Statistical reconstruction (SR) algorithms have the potential to significantly reduce X‐ray CT image artifacts due to a more realistic model of the detector signal acquisition process. Most SR algorithms assume that the CT detectors are photon‐counting devices and generate Poisson‐distributed signals. However, actual CT detectors integrate energy and exhibit compound Poisson distributed signal statistics. The goal of this study is to assess the impact on image quality of the resultant mismatch between the detector and signal statistics models assumed by the sinogram and the reconstruction algorithm. Method and Materials: A 2D CT projection simulator software was created to generate synthetic polyenergetic transmission data assuming i) photon‐count signals with simple Poisson distribution and ii) energy‐weighted compound Poisson distributed signals. An Alternating Minimization (AM) algorithm was used to reconstruct images from the data models i) and ii) for a typical abdominal scan protocol and for incident particle fluence levels ranging from 105 to 1.6×106 photons/detector. The phantoms simulated included normal soft tissue, bone, and metal inserts. The images reconstructed from data models i) and ii) were compared by visual inspection and quantitative image‐quality measures. Results: Substantial streaking artifacts appear in images formed from energy‐integrated data when the AM algorithm assumes a particle‐fluence spectrum Φ̄0(E). Once AM's spectrum is replaced by the energy‐fluence spectrum E ⋅Φ̄ (E), AM correctly predicts the data means and eliminates the artifacts. With the energy‐weighted spectrum, the reconstructed image quality from data models i) and ii) does not differ significantly even when SNR is very low. Conclusion: Mismatch between the actual and assumed CT detector signal statistics does not significantly degrade image quality once systematic data means mismatches are corrected. Within the context of statistical image reconstruction, there appears to be no benefit to develop more complex statistical reconstruction algorithms based upon energy‐integrating detector signal statistics models. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2057 / 2057
页数:1
相关论文
共 50 条
  • [31] POST-RECONSTRUCTION PROCESSING AND CORRECTION FOR POLYCHROMATIC X-RAY DISTORTION IN CT IMAGES
    NAPARSTEK, A
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (04) : 528 - 528
  • [32] Mesh-Based Reconstruction of Dynamic Foam Images Using X-Ray CT
    Renders, Jens
    De Beenhouwer, Jan
    Sijbers, Jan
    2021 INTERNATIONAL CONFERENCE ON 3D VISION (3DV 2021), 2021, : 1312 - 1320
  • [33] Reconstruction of patient-specific femurs using X-ray and sparse CT images
    Koh, Kyung
    Kim, Yoon Hyuk
    Kim, Kyungsoo
    Park, Won Man
    COMPUTERS IN BIOLOGY AND MEDICINE, 2011, 41 (07) : 421 - 426
  • [34] Three dimensional volume reconstruction of an object from x-ray images
    Roh, YJ
    Kim, BM
    Cho, HS
    Kim, HC
    OPTOMECHATRONIC SYSTEMS, 2001, 4190 : 181 - 191
  • [35] APPLICATION OF A DUAL-ENERGY MONOCHROMATIC X-RAY CT ALGORITHM TO POLYCHROMATIC X-RAY CT: A FEASIBILITY STUDY
    Chang, S.
    Lee, H. K.
    Cho, G.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2012, 44 (01) : 61 - 70
  • [36] Wobbled splatting - a fast perspective volume rendering method for simulation of x-ray images from CT
    Birkfellner, W
    Seemann, R
    Figl, M
    Hummel, J
    Ede, C
    Homolka, P
    Yang, XH
    Niederer, P
    Bergmann, H
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (09): : N73 - N84
  • [37] A study of four minimization approaches for iterative reconstruction in X-ray CT
    De Man, Bruno
    Basu, Samit
    Thibault, Jean-Baptiste
    Hsieh, Jiang
    Fessler, Jeffrey A.
    Bournan, Charles
    Sauer, Ken
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2708 - 2710
  • [38] Simulation of hub flaw X-ray images
    Huang, Qian
    Ou, Yanhua
    Shuju Caiji Yu Chuli/Journal of Data Acquisition and Processing, 2007, 22 (04): : 475 - 478
  • [39] ECT attenuation maps from x-ray CT images.
    Tang, HR
    Schreck, CE
    Hasegawa, BH
    Hawkins, RA
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 113P - 113P
  • [40] 3D Shape Reconstruction of Lumbar Vertebra From Two X-ray Images and a CT Model
    Longwei Fang
    Zuowei Wang
    Zhiqiang Chen
    Fengzeng Jian
    Shuo Li
    Huiguang He
    IEEE/CAAJournalofAutomaticaSinica, 2020, 7 (04) : 1124 - 1133