Statistical reconstruction of x-ray CT images from energy-integrated signals: A simulation study

被引:0
|
作者
Lasio, G
Whiting, B
Williamson, J
机构
[1] Virginia Commonwealth Univ, Richmond, VA 23284 USA
[2] Mallinckrodt Inst Radiol, St Louis, MO USA
关键词
D O I
10.1118/1.1998252
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Statistical reconstruction (SR) algorithms have the potential to significantly reduce X‐ray CT image artifacts due to a more realistic model of the detector signal acquisition process. Most SR algorithms assume that the CT detectors are photon‐counting devices and generate Poisson‐distributed signals. However, actual CT detectors integrate energy and exhibit compound Poisson distributed signal statistics. The goal of this study is to assess the impact on image quality of the resultant mismatch between the detector and signal statistics models assumed by the sinogram and the reconstruction algorithm. Method and Materials: A 2D CT projection simulator software was created to generate synthetic polyenergetic transmission data assuming i) photon‐count signals with simple Poisson distribution and ii) energy‐weighted compound Poisson distributed signals. An Alternating Minimization (AM) algorithm was used to reconstruct images from the data models i) and ii) for a typical abdominal scan protocol and for incident particle fluence levels ranging from 105 to 1.6×106 photons/detector. The phantoms simulated included normal soft tissue, bone, and metal inserts. The images reconstructed from data models i) and ii) were compared by visual inspection and quantitative image‐quality measures. Results: Substantial streaking artifacts appear in images formed from energy‐integrated data when the AM algorithm assumes a particle‐fluence spectrum Φ̄0(E). Once AM's spectrum is replaced by the energy‐fluence spectrum E ⋅Φ̄ (E), AM correctly predicts the data means and eliminates the artifacts. With the energy‐weighted spectrum, the reconstructed image quality from data models i) and ii) does not differ significantly even when SNR is very low. Conclusion: Mismatch between the actual and assumed CT detector signal statistics does not significantly degrade image quality once systematic data means mismatches are corrected. Within the context of statistical image reconstruction, there appears to be no benefit to develop more complex statistical reconstruction algorithms based upon energy‐integrating detector signal statistics models. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2057 / 2057
页数:1
相关论文
共 50 条
  • [41] BLIND POLYCHROMATIC X-RAY CT RECONSTRUCTION FROM POISSON MEASUREMENTS
    Gu, Renliang
    Dogandzic, Aleksandar
    2016 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING PROCEEDINGS, 2016, : 898 - 902
  • [42] 3D shape reconstruction of lumbar vertebra from two X-ray images and a CT model
    Fang, Longwei
    Wang, Zuowei
    Chen, Zhiqiang
    Jian, Fengzeng
    Li, Shuo
    He, Huiguang
    IEEE-CAA JOURNAL OF AUTOMATICA SINICA, 2020, 7 (04) : 1124 - 1133
  • [43] Simulation of images generated by the interaction of low energy X-ray radiation with materials
    Ilyasova N.Y.
    Kupriyanov A.V.
    Pattern Recognition and Image Analysis, 2014, 24 (03) : 452 - 456
  • [44] Statistical reconstruction for x-ray computed tomography using energy-integrating detectors
    Lasio, Giovanni M.
    Whiting, Bruce R.
    Williamson, Jeffrey F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (08): : 2247 - 2266
  • [45] The influence of bowtie filters on x-ray CT signals
    Whiting, B
    Massoumzadeh, P
    O'Sullivan, J
    Snyder, D
    Williamson, J
    MEDICAL PHYSICS, 2005, 32 (06) : 2056 - 2056
  • [46] 3D reconstruction and visualization from 2D X-ray CT images in the study of ceramic membrane microstructure
    Thomasova, Barbora
    Thomas, Jan
    Soucek, Kamil
    Michalek, Ondrej
    Gembalova, Lucie
    JOURNAL OF CERAMIC PROCESSING RESEARCH, 2020, 21 (06): : 712 - 724
  • [47] Integrated system simulation in X-ray radiography
    Kwan, TJT
    Mathews, AR
    Christenson, PJ
    Snell, CM
    COMPUTER PHYSICS COMMUNICATIONS, 2001, 142 (1-3) : 263 - 269
  • [48] Three dimensional simulation of fluid flow in X-ray CT images of porous media
    Al-Omari, A
    Masad, E
    INTERNATIONAL JOURNAL FOR NUMERICAL AND ANALYTICAL METHODS IN GEOMECHANICS, 2004, 28 (13) : 1327 - 1360
  • [49] Reconstruction of multi-energy x-ray computed tomography images of laboratory mice
    Gleason, SS
    Sari-Sarraf, H
    Paulus, MJ
    Johnson, DK
    Norton, SJ
    Abidi, MA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1081 - 1086
  • [50] Splitting-Based Statistical X-Ray CT Image Reconstruction with Blind Gain Correction
    Nien, Hung
    Fessler, Jeffrey A.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668